A
B
w
e
q
AE00241
GROUND (Earth)
Make sure to ground (earth) the generator.
Check "SAFETY INFORMATION" on page 7.
å EF4000DE/YG4000D
741-061
∫ EF5200DE/EF6600DE/YG5200D/YG6600D/YG6600DE
741-066
AE00231
BATTERY
(for EF4000DE/EF5200DE/EF6600DE/YG6600DE)
(See page 34 for more details)
Check the fluid level and fill if necessary.
Use only distilled water if refilling is necessary.
Installation
830-002a
1. Turn the engine switch to the "STOP" position to
prevent accidental short circuiting.
2. Install the battery on the battery mount tray
securely.
q
NOTE:
Clamp the red wire to the positive (+) terminal first,
then the black wire to the negative (–) terminal of the
battery. Do not reverse these positions.
762-004
w
Be sure to service battery leads to prevent arcing
when the battery is not installed.
9 Disconnect the battery charging output lead.
Then insulate the generator side connector by
762-005
folding it back on itself and carefully wraping it
with electrical tape to prevent electrical con-
tact with ground (earth) or any other leads.
9 Remove the battery leads from the generator.
1 Connector
2 Battery leads
3 Electrical tape
– 18 –