C
q
D
240V
Y
G
120V
W
X
120V
E
For YG4000D, YG5200D and YG6600D(E), also turn
the individual AC switch (N.F.B.) to the "ON" position.
1
ç Individual AC switch (YG4000D)
763-210
∂ Individual AC switch (YG5200D and YG6600D(E))
q
763-211
cC
Reduce the load to the specified generator rated
GR
output if an AC switch turns off. If it turns off
again, consult a Yamaha dealer.
NOTE:
779-017
9 The 4-blade plug receptacle can supply both 120V
9 The economy idle switch must be turned to "OFF"
q
- using a load of 0.8A or less.
- supplying AC120V only from W with X.
763-129a
´ Economy idle switch
1
I "ON"
and 240V power sources.
to increase engine speed to rated rpm when:
I "ON"
– 23 –