Manual 1. Product Introduction 1.1 Product introduction Thank you for purchasing the Elitech DMG Series Digital Manifold Gauge. Please read this manual carefully before use to ensure proper operation and avoid potential hazards. The DMG-2SE Digital Manifold Gauge integrates high-precision measurement, intelligent computation, and exceptional durability, significantly enhancing efficiency in HVAC applications.
2.At the end of its service life, dispose of the device in compliance with local disposal regulations. 3.Recycle used batteries at designated collection facilities. 1.5 Button Operations Long Press:Turn power ON/OFF Short Press:Toggle between settings options Long Press:Enter Settings Interface Short Press:Switch refrigerant types Long Press :...
Page 4
Supply Battery Life: 200 hours (low-power mode) Display LCD screen Dimensions Dimensions :110 x 75 x 135mm & Weight Weight:~600g Environme Operating Temperature:-10 to 50°C (14 to 122°F) ntal Storage Temperature:-20 to 60℃/(-4 to 140℉) Requireme Supported English,French, Spanish, Portuguese, Russian, Chinese Languages 2 Quick Start Guide 1.
2. Calibrate the pressure sensor to zero (long press to zero). Perform zero calibration of the pressure sensor before each measurement ( zero calibration range: -14.7-100psi ) . Before zeroing, be sure to cut off the connection of the instrument with any pressure source, and keep it balanced with the external pressure.
Switch settings : short press Select setting items : short press Exit settings : long press Figure 3 Setting interface diagram 3.3.1 Unit setting pressure unit 1. Enter Settings and select PRESS . 2. Short press to select the pressure unit. Temperature Unit 1.
3.3.3 Language Settings Enter settings, select LANG. 3.3.4 About 1. Enter Settings and select ABOUT . 2. Check the software version number, SN serial number. 3. Short press the key to view the SN serial number. 4 Maintenance and Care 4.1 Battery Replacement 1.
battery indicator low battery replace with new battery flashing Device shuts down 1.The device 1.Turn off the auto power unexpectedly auto-shutdown enabled off function 2.Battery is dead 2.Replace with new battery “----”displayed Measurement out of range Ensure readings remain temperature section within specified limits "OL"...