Page 1
XGUARD™ FOOD SHIELDS LIGHTS & WARMERS Thank you for choosing products from BSI. We appreciate your business and are available to assist you with all of your needs. This manual has been designed to help you better understand your product and its proper usage.
IMPORTANT OWNER INFORMATION Record your guards' model number(s) and warming unit serial number(s) (if applicable) to use as a reference when contacting your local representative or BSI headquarters. BSI Corporate Contact Information Model No.:...
The models shown below should be maintained in the same manner based on the instructions within this manual. The XGuard™ food shield must be installed in accordance with applicable installation code by a person familiar with the product's construction, operation, and potential hazards involved.
Page 4
OWNER'S MANUAL & WARRANTY XGUARD MODELS XG3930 XG3930-2 XG3930-3 XG3930-5 XG3935 XG3945 XG3945-3 XG3950 XG3950-2 Specifications subject to change without notice. 03.25 BSI, LLC 601 East 64th Avenue, Bldg. A, Denver, CO 80229 800.662.9595 sales@bsidesigns.com bsidesigns.com...
CUSTOMER SIDE CUSTOMER SIDE SERVER SIDE XGUARD™ BRACKETS There is no left or right XGuard bracket. By rotating the Glass Clamp on the Full XGuard Bracket Assembly, the bracket can convert from left to right. Full XGuard Top Shelf Center Top Shelf...
Top Shelf Bracket Center In the event that your XGuard product needs service and requires major repairs, contact your local installer for assistance. If you have questions about the products or need to replace minor parts you may contact BSI at 800.662.9595.
22-1/2 increments. GLASS AND BRACKET ADJUSTMENT XGuard brackets allow you to adjust the food shield height, reach and angle of glass. Referred to as the 'home' position, bracket and glass will be in vertical position (see Range of Motion image #1).
Glass: 36" x 14” (3/8" thick) Mounting: Above Counter • If unit is fitted with a BSI warmer, do not clean Time: 24 hours the glass or housing when warmer is hot. • Cleaning the warmer when hot can cause staining or damage to the warmer finish.
OWNER'S MANUAL & WARRANTY NSF REQUIRED END PANELS FOR XGUARD™ To meet NSF guidelines, end panels are included on all BSI quotations unless specifically excluded. XG3530 W/STANDARD END PANEL Location Part # Part Name 15931 Decorative Nut Clear Mylar Spacer...
OWNER'S MANUAL & WARRANTY ABOVE-COUNTER INSTALLATION FOR 1" XGUARD™ POSTS STAINLESS STEEL COUNTERS Letter Part # Part Name EZ Mount - 2" x 8" Flange 1" Threaded Post EZ Mount Center Flange Cover 1" Threaded 1" Threaded 10-32 x 1” S/S Screw Flat Philips...
Page 11
OWNER'S MANUAL & WARRANTY UNDER-COUNTER INSTALLATION FOR 1" XGUARD™ POSTS STAINLESS STEEL COUNTERS (requires under-counter reinforcement and access) Heavy-Duty Upright Flange or Narrow Heavy-Duty Inverted Flange or Narrow Upright Flange Inverted Flange Grommet Grommet Verify Flange Verify Angle by Others...
Page 12
OWNER'S MANUAL & WARRANTY ABOVE-COUNTER INSTALLATION FOR 1.5" XGUARD™ POSTS For Millwork Counter For Millwork Counter For Millwork Counter Surface Installation 720A/726A: Surface Installation 725A: Concealed Fastener Steel Post and Flange w/Flange Cut Flange (not for cantilever units) 720A Steel...
Stealth Heat/Light/Heat Combo Model 500 operation, and potential hazards involved. Specifications subject to change without notice. 03.25 BSI, LLC 601 East 64th Avenue, Bldg. A, Denver, CO 80229 800.662.9595 sales@bsidesigns.com bsidesigns.com...
Once your food guard has been properly installed and you have removed all zip ties, it will be important to keep your light, warmer, or combo unit clean to prolong the life of the product. BSI recommends the following for keeping your product clean: •...
496-60-BK Element:_60"_208V_Heater_1400W If you have product questions or need minor 496-66-BK Element:_66"_208V_Heater_1560W replacement parts, contact BSI at 1.800.662.9595. 240V Heat Elements are a special order item. Contact BSI at 1.800.662.9595 to order. REPLACING THE TUBULAR HEATING ELEMENTS On all three Stealth warmer units, the tubular heating element can burn out —...
Mount the infinite controllers near the wire chase/support leg. • The infinite controllers, light switch, and six feet of conduit/wiring exiting support legs are provided with all BSI lights & warmers. Specifications subject to change without notice. 03.25 BSI, LLC 601 East 64th Avenue, Bldg.
White * Pilot— Optional * Pilot— Optional Infinite Switch (208V/240V) - Part #582 Infinite Switch (120V) - Part #581 Specifications subject to change without notice. 03.25 BSI, LLC 601 East 64th Avenue, Bldg. A, Denver, CO 80229 800.662.9595 sales@bsidesigns.com bsidesigns.com...
(including, without limitation, to lost profits) arising in connection with the sale, use, inability to use, repair, or replacement of BSI, LLC’s products. The liability of BSI, LLC arising from any cause shall not exceed the price paid for the products.