Summary of Contents for QEED QA-POWER-M

  • Page 1: Table Of Contents

    ..................................... RS485 bus termination Register map ..................................................................Status LEDs ......................................Data logging – data acquisition ............................. Product features ....................................Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 2: Product Manual

    For further information, please contact your local authority, waste disposal service or the retailer from whom you purchased the product. Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 3: Product Overview

    PAGE 3 of 20 PRODUCT MANUAL PRODUCT OVERVIEW The QA-POWER-M is a single phase AC/DC direct insertion power analyser that can also be used as a voltage/current isolator. It can be used as a 1000V - 600V (100V - 60V for LV version), 10A AC/DC direct insertion or current transformer and variable frequency measurement.
  • Page 4: Inputs

    The default extension is text. The minimum sampling time is 1 second and the maximum is approximately 18 hours. Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 5: Technical Specifications

    ACTIVE: ± 0,5 F.S. REACTIVE: ± 0,5 F.S. Energy 1% on reading Power factor ± (0,001 +1%(1.00-PF)) Passband (-3dB) >2kHz Temperature coefficient <200ppm/°C Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 6: Available Measurements

    EN 61000-6-3 + A1 2011; EN64000-6-2/2005; EN61010-1/2010 Installation DIN rail mounting Order codes Standard version QA-POWER-M Low voltage version QA-POWER-M-LV T-BUS QA-TBUS-22 Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 7: Connection And Installation

    (see side diagram on the product box) With this configuration, the transformation ratio can be set via programming software or via RS485 using Modbus RTU registers. Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 8 The number of modules supported by the bus depends on the power supply used (please check the power consumption of the modules) Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 9: Rs485 Bus Termination

    RS485 cables. The following images are for illustrative purposes only: Power Supply T-BUS T-BUS T-BUS Figure 2: RS485 dynamic bus termination Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 10: Status Leds

    DATA LOGGING – DATA ACQUISITION The QA-POWER-M is able to provide a series of information regarding the module operation, alarm status, input type, output type, measured data reading, totalization, period and frequency measurement and module output value on a local USB PENDRIVE type memory (USB KEY) connected to the module via the microUSB port. The module is equipped with an RTC Real Time Clock powered by a backup battery, allowing the recording of data with year-month-day-hour-min-sec.
  • Page 11: Product Features

    AND/OR logic that can be set via register [40141]. Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 12: Device Configuration

    In addition to the configuration of various parameters, inputs and outputs, the Q-WIZARD also allows real-time monitoring of device variables. Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 13: Third-Party Modbus Master

    Exception code 1 byte 01, 02, 03, 04 (see note) 03: Illegal data value 2 bytes 04: Slave device failure Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 14: Function 06 Hexadecimal (Write Single Holding Register)

    Exception code 1 byte 01, 02, 03, 04 (see note) 03: Illegal data value 2 bytes 04: Slave device failure Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 15: Function 10 Hexadecimal (Write Multiple Registers)

    Exception code 1 byte 01, 02, 03, 04 (see note) 03: Illegal data value 2 bytes 04: Slave device failure Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 16: Firmware Update

    Partial serial number (format: mm-ss) UInt [16b] 40073 Serial Number (day, hour) Partial serial number (format: dd-hh) UInt [16b] 40074 Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 17 Address, parity, stopbits UInt [16b] 40119 2 → Even LSB: bit[2] = stop bits 0 → 1 1 → 2" Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 18 Positive Energy (Wh) Float [32b-LSW] 40219 Negative Energy SW Negative Energy (Wh) Float [32b-LSW] 40221 Vpeak SW Vpk (V) Float [32b-LSW] 40223 Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 19 RTC: second (0-59) UInt [16b] 41006 1=Reboot 2=Flash settings save Command 3=Set factory configuration UInt [16b] 42001 4=Reset Totalizer 5=Load Totalizer Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...
  • Page 20 UInt [32b-MSW] = Unsigned Integer (32 bit - MSW First Register) Int [64b-LSW] = Signed Long Long (64 bit - LSW First Register) Product Manual QA-POWER-M | QA-POWER-M-LV - Rev. A.1 issued 10.01.2025 GL 1.3 - QA-Power-M - v1.3.6.3 - ENG - 10.01.2025...

This manual is also suitable for:

Qa-power-m-lv

Table of Contents