This document provides the installation practice for the Calix GigaSpire BLAST GM1028H (u4hm) outdoor satellite system. Note that there are two separate models: 1. GM1028H GigaSpire BLAST u4hm outdoor ONU. This item is marketed in North America. 2. GM1028H-2 GigaSpire BLAST u4hm-2 outdoor ONU. This item is marketed in International markets.
Chapter 1 GigaSpire BLAST u4hm (GM1028H) Product Overview This chapter introduces the Calix GigaSpire BLAST u4hm (GM1028H) and BLAST u4hm-2 outdoor mesh Wi-Fi satellite system and provides an overview of installation considerations. Topics Covered This chapter covers the following topics: Introducing the GigaSpire BLAST u4hm (on page 9) ...
Coupled with the Calix GigaPro GPR8802x, the GigaSpire BLAST u4hm can be powered via an ethernet cable. In addition, the GigaSpire BLAST u4hm can also be powered locally (with a traditional power adapter), offering the ultimate outdoor location flexibility.
Additional Mounting Considerations From a best practice’s standpoint, keep the following in mind: Calix recommends mounting the BLAST u4hm as high as practical for Wi-Fi performance reasons. However, this deployment scenario still mandates that an AC power outlet is located within the power cord distance of the Wi-Fi source.
Powering Options The GigaSpire u4hm system supports two options for power: Local AC power: You can power the system via a standard AC power outlet using a Calix power adapter cable. PoE: You can line-power the system via the ethernet uplink data cable using a PoE injector ...
Page 15
Note: As a standards-based solution, the GigaSpire u4hm system can accept PoE power from any IEEE 802.3at compliant PSE. Performance may vary by manufacturer. To ensure the best possible performance, Calix recommends using the Calix PoE injector (100-06005) because it has been thoroughly tested for all supported use cases.
Note: The GigaSpire BLAST u4hm Wi-Fi AP system operates in satellite mode only. The GigaSpire BLAST u4hm Wi-Fi AP system can connect to the RG system via a wired or wireless connection. You can arrange satellites in a star or daisy-chain topology, adhering to the following...
Unpacking the GigaSpire BLAST GM1028H Each device is shipped individually in its own carton and contains the following: Part Number 100-05839 GigaSpire Blast u4hm (GM1028H) hardened dual band 2x2 Wi-Fi 6, GE WAN includes the following additional parts and supplies: The u4hm main device with interface cover pre-installed.
Identifying the Installation Location Calix recommends mounting the u4hm as high as practical for Wi-Fi performance reasons. However, this deployment scenario still mandates that an AC power outlet is located within the power cord distance of the Wi-Fi source (optional 16' power cord is available for outdoor installations).
Note: The GM1028H must be wall or pole mounted using the appropriate mounting bracket. Wall Mount Dimensions - GM1028H Satellite The Calix satellite GM1028H can be wall mounted. Keep the following information in mind when considering wall mounting: In a wall mount environment, the minimum distance between the u4hm and the ground is 3.3 ...
Page 28
2. Using the illustrations below, mark the two screw locations on the wall, making sure the device will remain level after mounting. Note: If attaching to sheet rock or gypsum board, Calix recommends using a wall anchoring system to ensure the bracket is securely attached.
Installing the System on a Pole The GigaSpire u4hm (GM1028H) can be pole mounted using an optional pole mount kit from Calix (100-05967). The kit consists of the following components: Pole Mount Bracket Bracket Hose Clamp (2) Ground Lug Cable assembly ...
Use a 20 AWG wire (not provided) for grounding. Connect the ground wire to the u4hm chassis using Calix supplied hardware (ring lug and Phillips pan-head screw with pawl washer) as described below. ALERT! Beware of electrostatic discharge. Follow standard ESD precautions.
After you have installed cables, the GigaSpire u4hm (GM1028H) system is ready to power up and connect to the network. Use one of the following procedures to apply power to the system. If you installed a Calix power adapter cable* to use a local AC power supply, follow the first procedure below.
Verify that the system LED shows as "in service". Refer to "System LED Behavior" for expected behavior. Verify with your back office that the system checked in to Calix Cloud as needed. Replacing Removed Covers Covers must be replaced before finalizing the installation. Perform the following steps: 1.