qfix RT-5100-04 User Manual

Symphony bos headframe transfer device

Advertisement

Quick Links

PRODUCT GUIDE
& USER MANUAL
RT-5100-04
Symphony® BoS™ Headframe Transfer
Device
Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA |
+1 484-720-6053 |
+1 610-268-0588 | www.Qfix.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RT-5100-04 and is the answer not in the manual?

Questions and answers

Summary of Contents for qfix RT-5100-04

  • Page 1 PRODUCT GUIDE & USER MANUAL RT-5100-04 Symphony® BoS™ Headframe Transfer Device Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 2 BoS, IntegraBite and Aquaplast RT are trademarks of Qfix. MOLDCARE® is a registered trademark of Alcare Co. Ltd. PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 3: Table Of Contents

    CLEANING THE SYSTEM .............................21 DISINFECTING THE SYSTEM ..........................21 SPECIFICATIONS .................................22 SETUP SHEET ..................................23 PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 4: General Precautions

    • Temperature: 0°C to 50°C (32°F to 122°F) • Humidity: 0% to 95% • Atmospheric: 700–1060 hPa PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 5: Mri Safety Information

    Symphony interferes with other electronic devices, move the trolley away from affected device(s). PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 6: Additional Precautions

    It is recommended to perform imaging studies on all transfer devices to characterize the physics properties and relative patient positioning, if necessary prior to clinical use. PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 7: Warning Labels & Descriptions

    GENERAL PRECAUTIONS WARNING LABELS & DESCRIPTIONS Refer to Qfix.com for a listing of symbols and their definitions. LOAD RATING The maximum safe working load for the BoS Transfer Device is 159 kg 159 kg < (350 lbs). Refer to the Instructions for Use of Receiving Systems and (350 lb) the Symphony®...
  • Page 8 If cantilevering the device, Symphony Locating Bars must be used. PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 9: Intended Use

    INTENDED USE The Qfix® Symphony® BoS Transfer Device is indicated to aid in the support, positioning, and transfer of a patient for head and neck procedures involving imaging, including MRI; and external beam radiation therapy treatment with electrons, photons or protons; and other general procedures requiring transfer of a patient. The Symphony BoS Transfer Device is designed to interface with other positioning devices, such as couchtops, inserts, thermoplastic masks and positioning pads.
  • Page 10: Symphony® Patient Transport System

    SYMPHONY® PATIENT TRANSPORT SYSTEM DESCRIPTION The Qfix Symphony Patient Transport System (the Symphony) is designed to maximize workflow efficiency and throughput. The Symphony is a fully integrated transport system consisting of a trolley system and interchangeable patient transfer devices designed for ease of use. Patient positioning and immobilization can be performed on a Symphony Transfer Device, enabling users to transport patients seamlessly to multiple imaging modalities and treatment systems.
  • Page 11: Getting To Know Your Symphony® Transfer Device

    3. Air Inlet 4. Symphony Transfer Handle (accessory) 5. Symphony Locating Bar (accessory) PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 12: Symphony® Transfer Device

    These markers are located on either side of the device and are intended to help guide the device to the alignment stops on the Symphony Locating Bar. (Fig. 4) PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 13 GETTING TO KNOW YOUR SYMPHONY® TRANSFER DEVICE SYMPHONY® TRANSFER DEVICE Fig. 4 PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 14: Air Inlet

    Hose, lift the cover to expose the air inlet. Push the hose into the air inlet. Fig. 6 PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 15: Symphony® Transfer Handle

    The releases are used to detach the Symphony Transfer Handle from the Symphony Transfer Device after use. PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 |...
  • Page 16 While squeezing the bottom portion of both red releases, pull the transfer handle away from the transfer device. (Fig. 9) Fig. 8 – Attach Fig. 9 – Detach PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 17: Symphony® Locating Bar

    Loosen the locking lever by rotating the handle counter-clockwise and remove the Symphony Locating Bar from the Receiving System. PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 18: Symphony® Bos™ Headframe Transfer Device

    Place the BoS foam head/neck support onto the neck area of the device. • MOLDCARE® may be used instead of the foam head/neck support. Qfix recommends RT-4492U for use with the BoS Headframe (refer to the MOLDCARE® Instructions for Use).
  • Page 19: Moving & Transferring With The Symphony System

    Ensure Symphony Transfer Handles are installed and all other accessories are removed from the transfer device. PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 |...
  • Page 20: Maintenance

    Fig. 11 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 21: Cleaning The System

    • Soap and Water To disinfect the Symphony Patient Transport System, refer to the specific instructions from the cleaning agent manufacturer. Qfix recommends spraying the cleaning solution onto a clean cloth, then using the cloth to wipe the device clean.
  • Page 22: Specifications

    6 kg (12.5 lb) 196 cm [77 in] 52 cm [22 in] PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 23: Setup Sheet

    Patient Name: Patient ID #: Setup by: Physician: Date: Comments: Notes: PRODUCT GUIDE AND USER MANUAL – 2007614_IFU, Symphony BoS Transfer Device_EN Qfix | 440 Church Road | Avondale, Pennsylvania 19311 USA | +1 484-720-6053 | +1 610-268-0588 | www.Qfix.com...
  • Page 24 440 Church Road Avondale, PA 19311 USA www.Qfix.com +1 484.720.6053 +1 610.268.0588 / 800.831.8174 2007614_EN_D sales@Qfix.com 2020-11...

Table of Contents