Page 2
Welcome Thank you for selecting MOISWELL as your trusted dehumidifier provider! At MOISWELL, we take pride in offering premium commercial and industrial dehumidifiers, available in both vertical and horizontal orientations. Our dehumidifiers are designed to swiftly reduce humidity levels, making them ideal for a wide range of applications, including excess water removal, rapid construction drying, and water damage restoration.
BEFORE FIRST USE: Please leave the dehumidifier standing upright and outside the box for 24 HOURS before plugging it in. The dehumidifiers may have been tilted or placed upside down during shipping. Leave the dehumidifier to stand upright for 24 hours so the oil in the compressor can settle from the move, not doing so can affect the performance or lifespan of the dehumidifier.
CONTENTS Warning For Using R32 Refrigerant ..................1 Parts Identification ........................12 Operation Instructions ......................13 1. Install the Handle ..................................13 2. Position Your Dehumidifier ............................... 14 3. Set Up the Drainage System ..............................14 4. Plug in Electrical Cord .................................. 15 5.
WARNING for Using R32 Refrigerant: Transportation, marking and storage for units that employ flammable refrigerants 1. General The following information is provided for units that employ FLAMMABLE REFRIGERANTS. 2. Transport of equipment containing flammable refrigerants Attention is drawn to the fact that additional transportation regulations may exist with respect to equipment containing flammable gas.
Page 6
Qualification of workers The manual shall contain specific information about the required qualification of the working personnel for maintenance, service and repair operations. Every working procedure that affects safety means shall only be carried out by competent persons. Examples for such working procedures are: •...
Page 7
2.7) Information about the correct working procedures: a) Commissioning • Ensure that the floor area is sufficient for the REFRIGERANT CHARGE or that the ventilation duct is assembled in a correct manner. • Connect the pipes and carry out a leak test before charging with refrigerant. •...
Page 8
• Remove the refrigerant. If the recovery is not required by national regulations, drain the refrigerant to the outside. Take care that the drained refrigerant will not cause any danger. In doubt, one person should guard the outlet. Take special care that drained refrigerant will not float back into the building.
Page 9
• Ensure sufficient ventilation at the repair place. • Be aware that malfunction of the equipment may be caused by refrigerant loss and a refrigerant leak is possible. • Discharge capacitors in a way that won’t cause any spark. The standard procedure to short circuit the capacitor terminals usually creates sparks.
Page 10
Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall be displayed. 8. Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work.
Page 11
11. Repairs to sealed components 1) During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is absolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
Page 12
15. Removal and evacuation When breaking into the refrigerant circuit to make repairs -or for any other purpose -conventional procedures shall be used. However, for flammable refrigerants it is important that best practice be followed, since flammability is a consideration. The following procedure shall be adhered to: Safely remove refrigerant following local and national regulations;...
Page 13
17. Decommissioning Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recovered refrigerant.
Page 14
Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of the flammable refrigerant.
Page 15
Recycling This mark indicates that this product should not be disposed of with other household wastes. To prevent possible environmental or human health harm from uncontrolled waste disposal, please recycle it responsibly to promote the sustainable reuse of material resources. P.11...
Parts Identification Handle Control Panel Air Inlet Air Outlet Pump Drain Outlet Gravity Drain Outlet Cord Winder Caster Power Cord Note: Do not obstruct the air inlet and/or outlet. P.12...
Operation Instructions 1. Install the Handle 1) Get the handle from the bottom packing foam. 2) Install the handle as illustrated below, please note to align the holes on the handle with the holes on the dehumidifier. 3) Tighten the screws with the included screwdriver until the handle is firmly attached. P.13...
2. Position Your Dehumidifier ●For optimal outcomes, use your dehumidifier in a confined space. ●Shut all entryways and windows. ●Position it clear of obstructions and avoid anything that could obstruct airflow in or out of the dehumidifier. Note: Place the dehumidifier on a flat surface to minimize vibration or noise. 3.
(2) Drain by Gravity The collected condensation water can be drained by gravity. When using gravity to drain: Connect the gravity drain hose through the outlet (Check the Pull out the drain hose inserted Remove the front covers. picture for reference). to the pump.
5. Understand the Control Panel The control panel of the dehumidifier features a user-friendly interface with 4 buttons and an LED screen. Press the POWER Button to turn the dehumidifier on. After turning on the Power/Purge dehumidifier, the LED screen will display the readouts. LED Display Timing Down...
Note: The humidity set-point is between 10% and 90%. A humidity setting between 40% and 60% is recommended for optimal comfort. Last, after selecting your target value, wait for 5 seconds for the setting to register automatically. This will ensure that your desired humidity level is set and maintained.
8. Smart Functions (1) 3 Minutes Compressor Protection Mechanism It prevents the dehumidifier from starting immediately after a complete cycle to avoid any potential damage. The compressor will start automatically after a 3-minute delay. During this time, the Fan icon is illuminating continuously on the LED screen and until the compressor kicks in, the water droplets icon illuminates.
Maintenance ! Ensure the dehumidifier is turned OFF and the plug is removed from the power socket before cleaning or maintenance is carried out. (1) Cleaning the Dehumidifier To clean the dehumidifier body, use a soft damp cloth. Do not submerge or pour water on the dehumidifier or control panel, as water can damage the electronic components.
Below chart will help you solve common problems may occur. If the problem coming across can not be fixed after troubleshooting or not being listed in the below trouble shooting chart, please contact MOISWELL customer service to get professional support service@moiswell.com...
Page 26
Solution Problem Possible Cause Set the target humidity percentage value at 10RH%, the dehumidifier works Humidity reading normally, which means this remains at 10RH%, Humidity sensor failure failure does not affect the ( far from the actual function of this dehumidifier. room humidity) Repair and replace the humidity sensor.