1. About This Guide This guide is intended for end users and describes Anker SOLIX X1 Battery Module in terms of product overview, maintenance, emergency handling, customer service, product information, and safety guidelines. Product Name Anker SOLIX X1 Battery Module...
2.4 Battery Capacity The battery module supports power and capacity expansion. Stack no more than one power module and four battery modules per column. Each power module can be installed with up to six battery modules. The following table lists the stacking examples and corresponding energy capacity.
3.1 Power On / Off After commissioning, the owner can only turn off the equipment using the Anker app until grid connection approval is granted. Once approval is complete, the equipment can be turned on and off using the Anker app.
3.2 Routine Maintenance To ensure the energy storage system operates properly for an extended period, it is recommended to perform routine maintenance. Only qualified professionals or trained personnel are allowed to operate and maintain the equipment. Power off the system before cleaning it, connecting cables, and ensuring grounding reliability. Check Item Check Method Maintenance Interval...
· Brief description of the issue For instance, if a ground fault is detected, the Anker app will send a notification, the light bar will turn red, and the power module's screen will show 'EE.' This complies with the Earth Fault alarm requirements of AS/NZS 5033.
· If there is an obvious odor, smoke, or fire, keep away from the equipment immediately and contact professional personnel. · Do not use the battery module if it has been dropped or hit. Please contact your installer. In all cases, once the situation is stable, contact the Anker Customer Service. 5. Customer Service support@anker.com...
Protection Class Class I Ingress Protection IP65 670 x 1080 x 150 670 x 1080 x 150 670 x 1080 x 150 mm Dimensions (W x 670 × 360 × 150 670 × 1080 × 150 670 × 720 × 150 mm mm + 670 x 360 x mm + 670 x 720 x + 670 x 1080 x 150...
f) Determine if the battery is inadvertently grounded. If inadvertently grounded, remove the source from the ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance (applicable to equipment and remote battery supplies not having a grounded supply circuit).
Page 12
7.2 Notice Declaration of Conformity Hereby, Anker Innovations Limited declares that this product is in compliance with the applicable directives/regulations (EU) 2023/1542, 2014/30/EU, and 2011/65/EU. The full text of the EU declaration of conformity is available at the following internet address: https://support.anker.com/s/articleRecommend?otherType=Anker_EN_Extemal_Manual_and_...
Page 13
60°C (140°F), sunshine or like, expose to extremely low air pressure or dispose of in fire or water. Replace only with specified batteries. License Holder: Anker Innovations Limited Anker Innovations Limited I Unit 56, 8th Floor, Tower 2, Admiralty Centre, 18 Harcourt Road, Hong Kong...