ASAIR AMS3 Series Instructions Manual

Gas mass flow meter

Advertisement

AMS3 Series Gas Mass Flowmeter
AMS3 Series Instructions
Gas mass flow meter
Integrated mass flow and temperature measurement
Good repeatability
Supports multiple gas measurements
Standard Modbus RTU communication
2 NPN open collector outputs (for upper and lower limit alarms)
TFT screen display (supports four display direction settings: up, down, left, and right)
9~28V DC power supply
Summary
AMS3 series gas mass flowmeter is based on the principle of thermal measurement, combined with the self-
developed MEMS flow sensor chip, to create an excellent performance, stable and reliable gas mass
flowmeter. The product calculates the mass flow rate of the measured gas by measuring the change of
resistance. It has the advantages of accuracy, stability, high and low temperature resistance, good linearity
and fast response. The alarm function is set inside the product, equipped with TFT display for reading display,
and the detection status is clear briefly; With RS485, NPN collector open circuit, 1 ~ 5V linear voltage and 4 ~
20mA linear current and other output modes, can meet the individual needs of different users.
The series has a variety of models, covering a variety of ranges, suitable for a wide range of scenarios.
Application
AMS3 series is suitable for mass flow monitoring of dry, clean, non-corrosive gases such as air and nitrogen
(except flammable and explosive gases). It has been widely used in university scientific research, fire
protection, environmental monitoring, tobacco, smart agriculture, food, medicine and other industries.
www.aosong.com
Figure 1. Appearance of AMS3 series products
August 2024
1 / 14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMS3 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ASAIR AMS3 Series

  • Page 1 The series has a variety of models, covering a variety of ranges, suitable for a wide range of scenarios. Application AMS3 series is suitable for mass flow monitoring of dry, clean, non-corrosive gases such as air and nitrogen (except flammable and explosive gases). It has been widely used in university scientific research, fire protection, environmental monitoring, tobacco, smart agriculture, food, medicine and other industries.
  • Page 2 Figure 2. AMS3 series structure diagram 1.2 DB9 male connector definition of the product The interface of the AMS3 series is a standard DB9 male connector . The DB9 connector pin diagram and pin definition are shown in Figure 3 and Table 1.
  • Page 3 1.3 AMS3 series pinout definition The AMS3 series is a DB9 female lead-out wire with a length of about 430 mm. The material is UL2464. There are 10 wires in total. The definitions are shown in Table 2. The actual picture is shown in Figure 4.
  • Page 4 AMS3 Series Gas Mass Flowmeter 2. AMS3 series technical indicators and basic information Table 3. AMS3 series model and range comparison table Mechanical Model Range Accuracy Output method connection ± 3 % FS AMS3001H00 10~1000L/min 2-RC 1/2 (100~1000L / min) ±...
  • Page 5 AMS3 Series Gas Mass Flowmeter 3. Main product dimensions and piping method 3.1 Main dimensions of AMS3 series Figure 5. AMS3001 Dimensions (Unit: mm) Figure 6. AMS3002 Dimensions (Unit: mm) www.aosong.com August 2024 5 / 14...
  • Page 6 AMS3 Series Gas Mass Flowmeter Figure 7. AMS3003 dimensions (unit: mm) Figure 8. AMS3006 Dimensions (Unit: mm) www.aosong.com August 2024 6 / 14...
  • Page 7 Figure 9. Piping diagram (1) For the air pipe connected to the air inlet port of the AMS3 series products, please reserve a straight pipe section that is greater than or equal to 10 times the inner diameter of the air inlet port, and the inner diameter of the straight pipe must be greater than or equal to the inner diameter of the air inlet port.
  • Page 8 The communication protocol is standard Modbus RTU. The host can be a computer, RS485 receiver, MCU controller, etc. The AMS3 series is a slave, the default address is 0x01, supports address modification, and can be connected to the bus of multiple slaves.
  • Page 9 AMS3 Series Gas Mass Flowmeter Take the operation of AMS3006H00 as an example, as follows. The host reads the instantaneous flow value of AMS3006H00 (the default slave address of the device is 0x01), the host sends a command to AMS300 6H00, and the data is 01 03 00 00 00 01 84 0A. The format is shown in Table 7.
  • Page 10 2 respectively. External output 1 controls the upper limit alarm, and external output 2 controls the lower limit alarm. If you purchase the AMS3 series lead wire, external output 1 ( NPN1 ) corresponds to orange, external output 2 ( NPN2 ) corresponds to gray, GND corresponds to black, blue or purple, and the wiring diagram is shown in Figure 10.
  • Page 11: Voltage Output

    5−1 5. Introduction to the main screen interface and setting menu functions The icons on the main screen interface of the AMS3 series are shown in Figure 11. Figure 11. Screen icon description ①: Lock screen icon; ②: 485 communication logo; ③: Flow alarm status; ④: Instantaneous flow;...
  • Page 12 AMS3 Series Gas Mass Flowmeter Table 10. Function description First level Secondary Level 3 menu Four-level menu Function menu menu Fluid AIR and N2 Select the gas type to be selection available measured Alarm switch On or Off Alarm function on or off...
  • Page 13: Packing List

    AMS3 Series Gas Mass Flowmeter 6. Packing list Table 11. Packing List Item Quantity AMS3 Series Gas Mass Flow Meter 1 unit AMS3 Series Lead Wire 1 unit Certificate 1 piece 7. Exception handling Table 12. Exception handling Fault phenomenon...
  • Page 14: Quality Assurance

    Warranty period description Product Categories Warranty AMS3 Series Gas Mass Flow Meter 12 months Cables or accessories 6 months The company is only responsible for defective products that are used in situations that meet the technical requirements of the product.

Table of Contents