ASAIR AFM07 Series Instruction Manual

Gas mass flow meters

Advertisement

Quick Links

AFM07 Series Instruction Manual
AFM07 Series Instruction Manual
Gas Mass Flow Meters
Integrated Mass Flow and Temperature Measurement
Good repeatability
Supports multiple gas measurements
Standard Modbus RTU communication
2 NPN open collector outputs (for upper and lower limit alarms)
1~5V linear voltage output
LCD screen display
9~24V DC power supply
Scope of Application
AFM07 series is suitable for air, nitrogen, argon, carbon dioxide, oxygen and other dry and clean non-
corrosive gases (except flammable and explosive gases) mass flow monitoring, has been widely used in
universities and colleges of scientific research, fire protection, environmental monitoring, tobacco, intelligent
agriculture, food, medicine and other industries.
1. Appearance structure and interface definition
1.1 Appearance Structure
Figure 2 shows the external structure of the AFM07 series, including the sensor duct and the working
interface. The working interface includes LCD display and operation keys, and the LCD displays the
flowmeter Modbus communication address, gas temperature, cumulative flow rate and instantaneous flow rate.
The buttons include three keys: up key, down key and set key, and lights 1 and 2 are the upper limit alarm
light and lower limit alarm light respectively. The sensor duct is below the working interface and includes the
air inlet and outlet.
www.aosong.com
Figure 1. AFM07 series product appearance
November 2023
1 / 12

Advertisement

loading
Need help?

Need help?

Do you have a question about the AFM07 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ASAIR AFM07 Series

  • Page 1 9~24V DC power supply Scope of Application AFM07 series is suitable for air, nitrogen, argon, carbon dioxide, oxygen and other dry and clean non- corrosive gases (except flammable and explosive gases) mass flow monitoring, has been widely used in universities and colleges of scientific research, fire protection, environmental monitoring, tobacco, intelligent agriculture, food, medicine and other industries.
  • Page 2 Figure 2. AFM07 Series Structure Schematic Diagram Exterior Structural Equipment Holder Definition The model number of the product holder for the AFM07 series is PHB-2*4AW, and the pin schematic and pin definitions are shown in Figure 3 and Table 1.
  • Page 3 1.3 AFM07 Series Lead Wire Definition The lead wire of AFM07 series is PHB2.0 double-row terminal wire (2*4) with buckle, the length of the lead wire is 30cm, the material is UL2464, and there are 8 wires in total, which are defined as in Table 2, and the physical drawing is shown in Figure 4.
  • Page 4 Product weight Enclosure Material Duct Material RS485, NPN open collector output, 1~5V linear voltage output 3. Dimensional drawings and piping methods 3.1 AFM07 Series Dimensions AFM07 series dimensional drawings are shown in Figure 5. www.aosong.com November 2023 4 / 12...
  • Page 5 2% F.S. or more. 4. Product communication protocols and outputs 4.1 RS485 communication The digital output communication method of AFM07 series gas mass flow meter is RS485 communication, and the communication parameters are shown in Table 4. www.aosong.com November 2023...
  • Page 6 The communication protocol is standard Modbus RTU. the host can be a computer, RS485 receiver and MCU controller, etc. AFM07 series as a slave, the default address is 0x01, the default baud rate is 9600, support to modify the address and baud rate, can access multiple slaves to the bus.
  • Page 7 AFM07 Series Instruction Manual Table 5.Modbus RTU Communication Register Definitions Read and functi register range of register Write factor note address values information Properties code Instantaneous Example: 21.8L/min 0x0000 0~65535 read-only flow rate 0x00da Cumulative 0x0001 0~65535 read-only Example: 123456789.5L...
  • Page 8 When the host reads the value of the instantaneous flow rate of the AFM07 series (the default slave address of the device is 0x01), the host sends the command 01 03 00 00 00 00 01 84 0A to the AFM07 series, and the data format is shown in Table 6.
  • Page 9 1 and external output 2 respectively, external output 1 controls the upper limit alarm and external output 2 controls the lower limit alarm. If the AFM07 series lead wires are purchased, external output 1 (NPN1) corresponds to the gray wire, external output 2 (NPN2) corresponds to the brown wire, and GND corresponds to the black and orange wires, the wiring diagram is shown in Figure 7.
  • Page 10 Voltage (V) = 1 + instantaneous flow rate (L/min) × voltage coefficient. The AFM07 series has two ranges, 25L/min and 50L/min, as shown in Table 3, and the voltage coefficients corresponding to the two ranges are 0.16 and 0.08, respectively.
  • Page 11 AFM07 Series Instruction Manual Table 9.Function Introduction Level 1 Level 2 Level 3 menu Level 4 menu Functions menu menu Select the type of gas to be Gas select measured Alarm switch Alarm function on or off Set the upper flow limit value,...
  • Page 12: Packing List

    Back to previous menu Exit Back to previous menu 6. Packing List Table 10.Packing List name (of a thing) quantities AFM07 Series Gas Mass Flow Meter 1 unit AFM07 series lead wire 1 strip Certificate of Conformity 1 sheet www.aosong.com...
  • Page 13: Quality Assurance

    Company will provide free repair or replacement services. Warranty Description Product category Warranty period AFM07 Series Gas Mass Flow Meter 12 months Wire or Gas Parts 6 months Our company is only responsible for products that are defective when used in applications that meet the technical conditions of the product.

This manual is also suitable for:

Afm0710Afm0725Afm0750Afm0711