Elkay Pro Filtration Installation & Use Manual
Elkay Pro Filtration Installation & Use Manual

Elkay Pro Filtration Installation & Use Manual

Bottle filling stations & coolers

Advertisement

Quick Links

LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV
INSTALLATION & USE MANUAL
Pro Filtration
Bottle Filling Stations & Coolers
Patent zurn-elkay.com/patents
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
Page 1
2000002266 (Rev. A - 03/25)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pro Filtration and is the answer not in the manual?

Questions and answers

Summary of Contents for Elkay Pro Filtration

  • Page 1 LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV INSTALLATION & USE MANUAL Pro Filtration Bottle Filling Stations & Coolers ™ Patent zurn-elkay.com/patents WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov Page 1 2000002266 (Rev.
  • Page 2: Table Of Contents

    Elkay assumes no responsibility for results obtained or damage incurred from the use of this material either in whole or in part by the buyer.
  • Page 3: Serial Number Location

    The following key words call the reader’s attention to potential hazards. This product is covered by a Limited Warranty and Elkay will not be held responsible for damage of any kind in Hazards are identified by the “Safety Alert Symbol”...
  • Page 4: Personal Safety

    LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV 2.3 Personal Safety Shock and Electrocution Hazards Failure to follow these instructions could WARNING result in severe burns, significant injuries, and even death. These warnings indicate a potentially hazardous situation which, if not avoided, could result in serious in Water will conduct electric current to jury or death.
  • Page 5: Property Damage

    LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV 3. Tools and Supplies Use Proper Tools 3.1 Tools Required Always use proper tools which are in good working condition during the installation of the product. Using tools other than those listed could Tool Used For adversely affect the product and could result in Tape Measure Locating mounting brackets...
  • Page 6: Preparation

    LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV 4. Preparation NOTICE Connect shut-off valve to water inlet. Do not use a piercing-type 4.1 General Information saddle valve for supply water which will reduces water flow and clogs easier. 1. This water cooler is designed for indoor use only and should not be installed outdoors or in a humid Note: This water cooler has been designed and built environment.
  • Page 7 LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV Fig. 1 Page 7 2000002266 (Rev. A - 03/25)
  • Page 8: Installation

    LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV 5. Installation 5.1 Instructions For Removing Wrapper Fig. B(ii) Fig. B(i) 1. Remove the two security screws (size T25) from the front panel. (see Fig B(i)) NOTE: SCREW THREADS INTO BUSHING WHILE ANGLED. DO NOT ATTEMPT TO THREAD SCREW INTO BUSHING HORIZONTALLY. 2.
  • Page 9: Instructions For Removing Wrapper

    LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV NOTE: Ensure that there are no plumbing or external objects below the wrapper in the specified dimension. The specified (3.27’’) minimum distance is required for the wrapper to swing out (see Fig B(iv)). 2. Removing the wrapper from the pivoting bracket when servicing the unit is recommended. The wrapper may be left in place for quick serviceability (see Fig B(iii)).
  • Page 10 LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV 3. Hang the unit on the two partially installed fasteners from step 2 using the mounting holes in row B on the unit. The unit should now be 9.31” above the cooler basin. Power Note: This is an intermediate step to aid in routing Supply Port the plumbing lines to the cooler and connecting the wiring harnesses;...
  • Page 11 LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV 10. Connect electrical power by plugging in unit’s power 7. Attach the tethers that are hanging from the control cord. board mounting bracket and the filter bracket to the corresponding PEM studs on the inside face of the 11.
  • Page 12 LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV 16. Verify proper dispensing from the bottle filler by placing a cup under the water dispenser spout and verify the bubbler operation by pressing the push bar on the front panel. Note: The first initial dispenses might have air in the line which may cause a sputter.
  • Page 13: Reference Figures

    LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV Reference Figures FIG. 2 FIG. 3 Secure cooler frame to wall by installing (2) screws and washers (not supplied). Fig. 4 Connect the bottle filler electrical harness. (Gasket removed from bottle filler for clarity) Fig. 5 OPERATION OF QUICK CONNECT FITTINGS OPERATION OF QUICK CONNECT FITTINGS SIMPLY PUSH IN...
  • Page 14 Mounting Bolt Holes (6) Tethers Wall Mounting Plate Tethers Fig. 7 BOTTLE FILLING UNIT 115V Refrigerated Wiring Diagram with Alpha/Numeric Display Connected-Ready - Enhanced Bottle Filler Programming Pro Filtration Bottle Button Alcove LEDs (2) Filling Station Electrical Diagram Module LZS8WSBPRO LZS8WSBPROUV RS232...
  • Page 15 Blue indicates normal operation, no immediate attention needed. Red indicates immediate attention required to maintain proper function. Scan for trouble shooting and to sign up for auto replenishment of authentic Elkay filters. Page 15 2000002266 (Rev. A - 03/25)
  • Page 16: Service Instructions

    LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV Note: Danger! Electrical shock hazard. Disconnect power before servicing unit. 7. Service Instructions Lower and Upper Shroud To access the refrigeration system and plumbing connections, Remove two (2) screws from front of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
  • Page 17: Programming Instruction

    LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV Programming Instruction Depress Button for 5 seconds to activate main menu, then release Display will cycle through all menu options for 2 seconds each for 2 cycles, then return to bottle count display if no user input is detected Display will cycle through all sub-menu options for 2 seconds each for 2 cycles, then return to main menu if no user input is detected Selections are saved upon exit from each sub-menu.
  • Page 18 IR sensor and clean sensor lens. • Close water shutoff valve, power cycle unit, and re-open valve. If error pesists, replace solenoid. • System could not detect genuine Elkay PRO filter in lower filter position. Lower filter BF04 Communication error - filter tag •...
  • Page 19 LZS8WSBPRO, LZS8WSBPRO-FSR5, LZS8WSBPRO-FLP4, LZS8WSBPRO-UV Pictured is unit only without bottle filler. Note: Danger! Electrical shock hazard. Disconnect power before servicing unit. Uses HFC-134A refrigerant See Fig. 9 12 or 13 See Fig. 11 21, 23 Fig. 13 Page 19 2000002266 (Rev. A - 03/25)
  • Page 20: Frequently Asked Questions (Faq)

    FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 PRINTED IN U.S.A. • ELKAY MANUFACTURING COMPANY • 1333 BUTTERFIELD ROAD SUITE 200 • DOWNERS GROVE, IL 60515 • 630.574.8484 www.elkay.com 2000002266 (Rev. A - 03/25) Page 20...