Contents Parts Included……………………………………………………………………………..3 Set Up……………………………………………………………………………………...4-6 Operating Instructions: Connecting to a vessel…………………………………………………………….6 Switching on power………………………………………………………………...7 Setting target pressure…………………………………………………………….7 Starting a fill…………………………………………………………………………8 Pausing a fill………………………………………………………………………...9 Auto Cooling………………………………………………………………………...9 Auto Cut-Off & Depressurisation…………………………………………………. Lubrication check timeout…………………………………………………………10 Setting units of pressure…………………………………………………………..11 Trimming calibration……………………………………………………………….12 Troubleshooting…………………………………………………………………………..13 Closedown………………………………………………………………………………...13 Storage…………………………………………………………………………………….13 Maintenance………………………………………………………………………………13 Rev 1: Jun 2023...
Parts Included 1x EC-3000 evo Compressor 1x Power Cable 1x High Pressure Filling Hose 1/8” and male Quick Release Coupling 1x Hill A73 Crank Oil 1x Hill A72 Silicone Oil Rev 1: Jun 2023...
SET UP CAUTION - Please read and understand the following instructions before use. CAUTION - Once the compressor has been correctly filled with lubricants, the compressor must be kept upright at all times. Ensure the compressor is used on an anti-slip floor, preferably placed on anti-slip matting.
Page 5
2) Silicone Oil Level Top up the silicone oil reservoir as per the following procedure: — Ensure the correct oil type is used. — Remove silicone oil reservoir blue cap by unscrewing (anti-clockwise). — Slowly squeeze the Hill A72 silicone oil into the exposed hole until the lubricant level meets the blue max level line indicated on the reservoir.
3) Power connection Insert the C13 power cable into the C14 socket on the left hand side of the compressor. Please avoid using any electrical extension leads if possible. However, if you must use a third-party extension lead, this must be as short as possible and must be rated to minimum of 110V / 16A or 230 V / 13 A depending on your local power supply.
Operating Instructions Switching on power Power up the compressor using the red switch on the left hand side. The display will briefly show the Hill logo, the firmware version and the running time. Next, the compressor will request the user to confirm the lubricant levels have been checked and are correct.
Starting a fill First navigate to the start display by rotating the rotary control knob clockwise while in the main menu. The start display shows the current cylinder block temperature and the selected target pressure. If the compressor detects that there is high pressure (roughly greater than 20 BAR / 290 PSI) in the system, this pressure will be displayed on the lower left of the start display.
Pausing a fill A fill can be paused at any time by pressing the rotary control knob once. After pausing a fill, rotating the rotary control knob in either direction will cycle between the option to resume or abort the current fill. Auto Cooling The compressor is designed to operate within a specific temperature range.
Auto Cut-Off & Depressurisation When the target pressure has been reached, the display will show “Fill Complete”. It is normal for the achieved pressure to reduce by up to 5% after the fill has completed, particularly in smaller vessels. This is due to the effect of cooling and flow losses.
Setting units of pressure The unit of indicated pressure used throughout the operation of the compressor is user selectable as BAR, PSI or MPa. The unit of indicated pressure can be selected on the first page of the settings menu. The settings menu is accessible from the second page of the main menu.
Trimming Calibration The compressor is factory calibrated and should accurately sense its internal pressure out of the box. It is however possible that over many hours of use, some pressure sensor drift could occur. To compensate for the occurrence of slight pressure sensor drift, the compressor features a trim calibration setting.
Troubleshooting - Compressor will not turn on: Make sure that the power cable is inserted correctly and that the fuses in the power cable plug and next to the compressor switch are present and functional. - Pressure does not exceed 50 BAR and/or air escapes from the Pressure Relief Valve (PRV): With the bleed screw open, run the compressor for 5 mins and then attempt another fill.
Page 14
DO NOT LEAVE THE COMPRESSOR UNATTENDED WHEN IN USE! IN THE UNLIKELY EVENT OF MALFUNCION, PLEASE CONTACT THE DISTRIBUTOR FOR AD- VISE BEFORE ATEMPTING REPAIRS. PLEASE RETAIN THE ORIGINAL RECEIPT OF PURCHASE, AND ANY RECIEPTS FOR SERVICE KITS PURCHASED. The most up to date version of this manual will be available at: www.airiflepump.com Please check this website regularly.