،العميل عزيزي Dear Customer, الجهاز لهذا شرائك على نشكرك Thank you very much for buying this appliance. و ي ُرجى للمنتج استخدامك قبل بعناية هذا التشغيل دليل قراءة ي ُرجى Please read through the manual carefully before using the والتشغيل ،المستمر...
Do not modify this appliance. Recommendations Warning Installation and maintenance of the boiler must be carried out by the authorised Baxi Service Network in accordance with local and national regulations Warning Removal and disposal of the boiler must be carried out by a qualified installer in accordance with local and national regulations.
To guarantee optimum operation of the system, you must abide by the following instructions: Read and follow the instructions given in the manuals provided with the appliance. Contact the authorised Baxi Service Network to carry out installation and initial commissioning. Ask your installer to explain your installation to you.
2 USER INSTRUCTIONS Symbols used in the manual This manual uses various danger levels to draw attention to special instructions. We do this to improve user safety, to prevent problems and to guarantee correct operation of the appliance. Danger Risk of dangerous situations that may result in serious personal injury. Danger of electric shock Risk of electric shock.
2 USER INSTRUCTIONS In “heating only” boilers, the heated water is delivered to the heating system or, if present and if requested, to a domestic hot water tank. A temperature sensor sends the heat request signal from the DHW tank to the power circuit board which switches the three-way valve to the DHW position and operates the pump.
2 USER INSTRUCTIONS Chimney sweep function keys Important Press the F1 and F2 keys simultaneously. Menu keys Important Press the F3 and F4 keys simultaneously. Calibration mode keys: Press keys F1 and F4 simultaneously 2.3.3 Meaning of the symbols on the display Tab.48 Symbols on the display Chimney sweep mode is enabled (forced operation at maximum or minimum output for O...
Important The flow temperature is matched automatically when using a: Weather-dependent regulator. OpenTherm regulator. Modulating thermostat BAXI MAGO BO-0000271-6 2.4.3 Changing the domestic hot water (DHW) temperature Fig.59 1. Press the keys F7 - F8 to set the desired temperature.
The boiler does not require complicated maintenance. We nevertheless recommend inspecting it frequently and performing maintenance on it at regular intervals. Boiler maintenance and cleaning must be carried out at least once a year by the authorised Baxi Service Network. Ensure that the appliance is not supplied with voltage.
Maintenance instructions To ensure its safety, functionality and optimum efficiency over time, the appliance must be inspected every year by the authorised Baxi Technical Support Service Careful maintenance is always a source of safety and savings in managing the installation.
2 USER INSTRUCTIONS Fig.65 Purging the installation 1. Open the valves A and B on all radiators connected to the heating system. 2. Set the ambient thermostat to the highest possible temperature. 3. Wait until the radiators are warm. 4. Set the ambient thermostat to the lowest possible temperature. 5.
(2) Fuel 2.8.2 Product fiche - Temperature controls Tab.50 Product fiche for the temperature controls For use with For use with BAXI MAGO modulating heat ON/OFF heating ing systems systems Class Contribution to space heating energy efficiency INSTRUCTIONS FOR THE INSTALLER Technical specifications 3.1.1...
3 INSTRUCTIONS FOR THE INSTALLER Electromagnetic Compatibility Directive 2014/30/EU Low Voltage Directive 2014/35/EU Ecodesign Directive 2009/125/EC Regulation (EU) No. 2017/1369 (for boilers with P<70 kW) Ecodesign Regulation (EU) No. 813/2013 Energy Labelling Regulation (EU) No. 811/2013 (for boilers with P<70 kW) In addition to the provisions and legal directives, also the complementary directives described in these instructions must be observed.
Page 88
3 INSTRUCTIONS FOR THE INSTALLER LUNA COMPACT 1.24 1.28 Useful heat out put at rated heat output and high 24.0 28.0 19.0 20.0 24.0 28.0 temperature set ting Useful heat out put at 30% of rat ed heat output and low tempera ture setting Space heating –...
Page 89
3 INSTRUCTIONS FOR THE INSTALLER Tab.53 General LUNA COMPACT 1.24 1.28 Rated heat input (Qn) for 28.9 28.9 19.6 24.7 28.9 32.0 domestic hot water Rated heat input (Qn) with 28.9 32.0 domestic hot water tank Rated heat input (Qn) for 24.7 28.9 19.6...
Page 90
3 INSTRUCTIONS FOR THE INSTALLER Tab.56 Combustion characteristics LUNA COMPACT 1.24 1.28 G20 gas consumption 2.61 3.06 2.07 2.61 3.06 3.38 (Qmax) G20 gas consumption (Qmax) with domestic hot 3.06 3.06 – – water tank G20 gas consumption 0.31 0.34 0.26 0.26 0.31...
3 INSTRUCTIONS FOR THE INSTALLER 3.1.6 Features of the temperature sensors Tab.59 Temperature sensor outdoor sensor (NTC1000 Beta 3419 1 kOhm @ 25 °C) Temperature [°C] Resistance [Ω] 7578 5861 4574 3600 2857 2284 1840 1492 1218 1000 Tab.60 Temperature flow/heating circuit return sensors, DW tank and DW sensor (NTC10K Beta 3977 10 KOhm @ 25 °C) Temperature [°C] Resistance [Ω] 32505...
Page 92
3 INSTRUCTIONS FOR THE INSTALLER Fig.67 Paper template Heating + Domestic Hot Water combi model Ø 116 min Ø 116 min 5 mm 5 mm 0÷ 15 mm 0 ÷ 15 mm 3/4” 1/2” 3/4” 3/4”-1/2” 3/4” Ø 21.8 BO-7745516 LUNA COMPACT 7873052 - 01 - 07062024...
A paper template An installation, user and service manual Dowel/screw kit for fastening the boiler to a wall 3.2.5 Accessories & options All accessories and options are available by consulting the Baxi price list. LUNA COMPACT 7873052 - 01 - 07062024...
3 INSTRUCTIONS FOR THE INSTALLER Before installation 3.3.1 Installation requirements Warning The following technical instruction notes are intended for installers. Important Information on an additional pump:In case of installation of an external pump, make sure that its flow rate-head data are compatible with the characteristics of the system. This ensures correct operation of the appliance. Important Information on solar systems: If an appliance without a domestic hot water (DHW) tank is connected to a solar energy system, the maximum domestic water temperature must not exceed 60 °C.
3 INSTRUCTIONS FOR THE INSTALLER Circulating pump The system uses a high-head, modulating pump that is suitable for use on any type of one- or two-pipe heating installation. The automatic air vent valve built into the pump body enables fast venting of the heating installation. Operation of the pump in DHW mode —>...
3 INSTRUCTIONS FOR THE INSTALLER 3.3.3 Choice of the location Fig.73 Dimensions BO-0000227 Important In order to make it easier to install and remove the boiler's flue gas adapter, it is recommended to respect the dimensions indicated in the figure (expressed in mm) based on the type of adapter used (A, B). Before installing the boiler, identify the ideal position for its assembly, taking into account: Standards in force;...
3 INSTRUCTIONS FOR THE INSTALLER Fig.75 Data plate Tab.65 Description of the data plate "BRAND" Commercial brand. “Code” “Comm.Code” “BRAND” "Code" Product code. “Product name” "Comm.Code" Product commercial code. Qn Hi xx - xx xx - xx Pn 80/60°C xx - xx xx - xx "Product name"...
3 INSTRUCTIONS FOR THE INSTALLER Install the product, starting from the position of the hydraulic and gas connections. Make sure that the rear part of the boiler (back) is as parallel to the wall as possible (otherwise, increase the thickness of the smaller area). In the case of pre-existing systems and if replacing them, in addition to the aforementioned, it is recommended to provide a magnetic filter, on the boiler return, to collect any deposits and debris, even those that may be present after washing the system and that over time could be put into circulation.
3 INSTRUCTIONS FOR THE INSTALLER Fig.78 Recommended locations A 1/2 Z 1/2 H (min. 2,5 m) MW-8800N001-3 1/2 H (min. 2,5 m) Optimum location Possible position Inhabited height controlled by the sensor Inhabited area controlled by the sensor Recommended locations (A): On a façade of the area to be heated, facing north.
Page 103
3 INSTRUCTIONS FOR THE INSTALLER Notice Before connecting the pipes, remove all the protective plugs. Warning The heating pipes must be installed in accordance with prevailing provisions. The drain pipe of the safety valve must not be soldered. Carry out any welding work required at a safe distance from the boiler or before the boiler is installed.
3 INSTRUCTIONS FOR THE INSTALLER Tab.67 Volume of the expansion vessel in relation to the volume of the heating circuit Volume of the installation (litres) Initial pressure of the ex pansion vessel > 300 0.5 bar (50 kPa) 12.0 14.4 Volume of the system x 0.048 1 bar (100 kPa) 7.0 *...
3 INSTRUCTIONS FOR THE INSTALLER 3.4.7 Air inlet/flue gas outlet connections Classification Fig.81 Installation examples BO-0000053 Appliance used for connection to a chimney for the evacuation of the products of combustion outside of the room in which it is installed. The combustion air is taken directly from the room. Appliance B is used for connection to an exhaust system designed to operate with positive pressure.
Page 106
3 INSTRUCTIONS FOR THE INSTALLER Important The chimney must be swept before installing the flue gas exhaust pipe. To avoid transmitting noise into the home while the boiler is operating, do not wall up the pipes of the flue gas exhaust system but use a sleeve.
Page 107
3 INSTRUCTIONS FOR THE INSTALLER 18 mm BO-0000280 Flue gas tower and coaxial pipes fastened using screws Fasten the intake pipes with two galvanised Ø 4.2 mm screws with a maximum length of 16 mm. Important If you purchase products not produced by the manufacturer, we recommend purchasing screws of a similar length and size.
Page 108
3 INSTRUCTIONS FOR THE INSTALLER Coaxial pipe installation examples Fig.85 Coaxial pipe installation examples BO-0000054 Table of exhaust types C(10)3 COLLECTIVE CHIMNEY OPERATIONAL WITH POSITIVE PRESSURE FOR SEALED CHAMBER BOILERS The sizing of the collective chimney is determined by the supplier, pursuant to regulation EN 13384-2.
Page 109
3 INSTRUCTIONS FOR THE INSTALLER Tab.69 Type of flue gas connection: C and C (natural gas) (10)3 (12)3 1.24 1.28 LUNA COMPACT Minimum Maximum Maximum Minimum Maximum Maximum Fan speed correction Par. GP067 – – GP067 – – – – –...
Page 110
3 INSTRUCTIONS FOR THE INSTALLER Max. DHW flue gas temperature °C Flue duct minimum length 60/100 Flue duct maximum length 60/100 Important In the case of maintenance/disassembly of the boiler combustion circuit installed on a collective flue in positive pressure, take the necessary precautions to prevent the fumes from other boilers installed on the collective flue from entering the room where the boiler is installed.
Page 111
3 INSTRUCTIONS FOR THE INSTALLER Caution Make sure to correctly fasten the splitter fitting by turning it from position “0” to position “1” as shown in the figure. Caution Guarantee a minimum slope of the flue gas evacuation pipe towards the boiler of at least 5 cm per metre. Fig.87 Pipe installation for separate pipes 77,5...
3 INSTRUCTIONS FOR THE INSTALLER Tab.72 Maximum flue gas pipe lengths 1.24 - 1.28 - 20 - 24 - 28 - 32 Fitting type Ø [mm] L [m] 80/80 80/50 * 80/60 ** 60/100 80/125 – * 50 mm diameter flue gas exhaust with a rigid and flexible pipe. ** 60 mm diameter flue gas exhaust with a rigid pipe.
3 INSTRUCTIONS FOR THE INSTALLER Flue gas pres Flue gas pres GP068 [%] GP088 [%] GP068 [%] GP088 [%] sure [Pa] sure [Pa] L2 [m] – 28 kW 24 kW – 32 kW 28 kW 11-20 21-30 * Factory setting 3.4.9 Electrical connections The electrical safety of the equipment is only ensured when it is correctly connected to an effective earthing system in...
3 INSTRUCTIONS FOR THE INSTALLER To add one or more wires to the boiler wiring, proceed as follows: undo the screw (1) on the multiple cable feed-through (A) located on the lower right-hand side of the boiler (the screw serves a cable gland);...
3 INSTRUCTIONS FOR THE INSTALLER Connecting the domestic hot water tank sensor Fig.93 Connecting the DHW tank sensor Connect the sensor of the external storage tank to terminal 3-4 (Tdhw/TS) of terminal block M2 as shown in the figure to the side. ENABLE Tdhw Tout...
Proceed as follows to drain the installation: Flush the installation. Clean the installation with products recommended by BAXI to eliminate debris from the system (copper, hemp, flux). Thoroughly flush the installation until the water runs clear and shows no impurities Installing the boiler in pre-existing installations: Remove sludge from the installation.
3.5.4 Gas settings Only the authorized Baxi Service Network can carry out the commissioning of the product and, if necessary, the gas change. Gas valve Proceed as described below to commission the boiler:...
3 INSTRUCTIONS FOR THE INSTALLER Fig.98 Gas valve 1. Open the main gas cock. 2. Open the gas cock on the boiler. 3. Open the front panel. 4. Check the gas supply pressure at pressure test point Pi on the gas valve (figure opposite).
3 INSTRUCTIONS FOR THE INSTALLER Fig.100 Examples of combustion checks Important On this appliance, it is not necessary to make any mechanical adjustment to the valve. The gas valve adjusts itself automatically Caution To analyse the products of combustion, ensure adequate heat exchange in the system in heating mode or in domestic water mode (by opening one or more domestic hot water cocks) to avoid the boiler shutting down as a result of overheating.
3 INSTRUCTIONS FOR THE INSTALLER 2. Press the F3 button When the letter h appears on the display (followed by the flow temperature) the boiler is working at maximum power in HEATING MODE. BO-0000272-13 3. Press the F3 button When the letter H appears on the display (followed by the flow temperature) the boiler is working at maximum power in DOMESTIC WATER MODE.
3 INSTRUCTIONS FOR THE INSTALLER Fig.103 Disabling operation in domestic To disable the boiler operation in domestic hot water mode: water (DHW) mode Press the F2 key to select the domestic hot water temperature. Press the F2 key repeatedly until OFF is displayed. To confirm, press the F4 key.
3 INSTRUCTIONS FOR THE INSTALLER 3.9.2 List of settings Tab.80 Table of settings Name Description Factory value Minimum Maximum Level Manual heating request enabled based on imple mentation of setting AP026 AP002 – – Installer 0: Disabled 1: Enabled Minimum water pressure in the system. If the water pressure is lower than this value, the appliance sig...
Page 125
3 INSTRUCTIONS FOR THE INSTALLER Name Description Factory value Minimum Maximum Level Maximum time required to completely fill the sys AP071 3600 Installer tem [seconds] Summer-winter heating on/off (with outside sensor connected). When the outside temperature is above this threshold, the appliance is in summer AP073 User mode and will not start for central heating.
Page 126
3 INSTRUCTIONS FOR THE INSTALLER Name Description Factory value Minimum Maximum Level Type of reduced night mode: CP340 0: Stop heat request – – Installer 1: Continue heat request Temporary room temperature value set for the zone CP510 User [°C] Fireplace mode CP550 0: Disabled...
Page 127
3 INSTRUCTIONS FOR THE INSTALLER Name Description Factory value Minimum Maximum Level Enabling the tank sensor/thermostat DP150 0: DHW (Domestic Hot Water) sensor Installer 1: DHW (Domestic Hot Water) thermostat Set value for anti-legionella in DHW (with external DP160 Installer boiler) [°C] DP170 Save start of holiday period...
Page 128
[minutes] PP016 Maximum pump speed in heating mode (%) Installer PP018 Minimum speed for the boiler pump [%] Installer Tab.81 Parameter table with BAXI MAGO Factory Name Description Minimum Maximum Level value Required ambient temperature (°C) in the zone in...
3 INSTRUCTIONS FOR THE INSTALLER Factory Name Description Minimum Maximum Level value Zone operating mode 0: Programming CP320 User 1: Manual 2: Off Type of reduced night mode CP340 0: Stop heat request Installer 1: Continue heat request Temporary room temperature value set for the zone CP510 User [°C]...
3 INSTRUCTIONS FOR THE INSTALLER To modify the value of CN1 and/or CN2 press the keys F7-F8 then press the F4 key to confirm. 3.9.4 Setting the heating curve Connect the outside sensor to terminals 5-6 and connect the "On/Off" type room thermostat or the "Open Therm" type room unit to terminal 7-8 of the M2 terminal board after having removed the jumper.
3 INSTRUCTIONS FOR THE INSTALLER Press the F1 key to exit Tab.82 Read-only parameter list (not editable) Setting Description Value (read only) AM001 DHW (Domestic Hot Water) mode enabled (0: Disabled, 1: Enabled) AM010 Pump speed (0 ÷ 100%) AM011 Service required (0: Disabled, 1: Enabled) AM012 Status of appliance...
3 INSTRUCTIONS FOR THE INSTALLER SUB-STATUS Operation at set temperature setpoint Operation at limited temperature setpoint Operation at required output Level 1 gradient detected Level 2 gradient detected Level 3 gradient detected Flame protection active Stabilisation time Boiler start at minimum output Operation in heating mode has been interrupted by a domestic hot water request.
The boiler does not require complicated maintenance. We nevertheless recommend inspecting it frequently and performing maintenance on it at regular intervals. Boiler maintenance and cleaning must be carried out at least once a year by the authorised Baxi Service Network. Ensure that the appliance is not supplied with voltage.
2. Check the condition and correct position of the flame detection and ignition electrode; 3. Check the condition of the burner and that it is correctly fastened; 4. Check for any impurities located inside the combustion chamber. To do so, use a vacuum cleaner or the Baxi cleaning kit available as an accessory;...
3 INSTRUCTIONS FOR THE INSTALLER Checking combustion Measure the content of CO and the flue gas discharge temperature at the dedicated measuring point. Checking the automatic air vent valve To access the boiler pump, remove the front panel and lower the control panel. Check that the pump air vent valve is working. In the event of a leak, replace the valve.
Repeat the process. Wait another 8 minutes and then brush again. If the result is not satisfactory, repeat the operation (these products are available as BAXI accessories). 19. Rinse with water to remove any dirt particles. The water will flow out of the heat exchanger through the condensate drain siphon.
Page 138
6. Fit the filter back inside the cartridge and reinsert it into its seat, securing it with its clip; Notice If the O-rings in the water unit need to be replaced and/or cleaned, do not use oil or grease as a lubricant, but only additives recommended by BAXI. Fig.107 Heating + DHW combi boiler water unit parts...
3 INSTRUCTIONS FOR THE INSTALLER Fig.108 Heating only boiler water unit parts BO-0000309 3.10.5 Specific maintenance operations Detection/ignition electrode replacement To remove the electrode: Disconnect the power supply to the boiler. Cut off the gas supply to the boiler. Remove the front panel on the boiler (case) and remove the electrode pin and the earthing cable. Unscrew the 2 screws on the ignition electrode and remove it.
PERMANENT FAULT (E.x.x) A permanent fault is shown on the display by the letter "E" followed by a number (group). Press the RESET key for 1 second. If faults are shown frequently, contact the authorised Baxi Service Network. E: Stoppage, RESET required.
Page 141
3 INSTRUCTIONS FOR THE INSTALLER DISPLAY WARNING DESCRIPTION CAUSE – Check/Solution Check the pressure switch wiring Check the water filling valve A02.33 Maximum top-up duration exceeded error Check/replace the PCB Check for boiler/installation leaks Check the pressure switch wiring For automatic filling, the minimum time interval be Check the water filling valve A02.34 tween two requests has not been reached...
Page 142
3 INSTRUCTIONS FOR THE INSTALLER CAUSE – Check/Solution DISPLAY DESCRIPTION OF TEMPORARY FAULTS An installer is required for most checks and solutions. INSUFFICIENT CIRCULATION Check the boiler/installation circulation Activate a manual venting cycle Check the installation pressure H01.08 Flow temperature increase in heating system too fast OTHER CAUSES Check the cleanliness of the exchanger Check the operation of the temperature sensors...
Page 143
3 INSTRUCTIONS FOR THE INSTALLER CAUSE – Check/Solution DISPLAY DESCRIPTION OF TEMPORARY FAULTS An installer is required for most checks and solutions. BOILER / SYSTEM AUTOMATIC FILLING ERROR The maximum number of autofills allowed has been H02.38 Maximum number of automatic filling cycles reached reached Check for boiler/installation leaks Contact the Service Network...
Page 144
3 INSTRUCTIONS FOR THE INSTALLER CAUSE – Check/Solution DISPLAY DESCRIPTION OF TEMPORARY FAULTS An installer is required for most checks and solutions. ELECTRODE PROBLEM Check the electrode electrical connections Check the electrode condition GAS SUPPLY Check the gas supply pressure Check the setting FLUE GAS EXHAUST PIPE H20.36 Manual calibration failed...
Page 145
3 INSTRUCTIONS FOR THE INSTALLER PERMANENT ANOMALIES DESCRIPTION (RE CAUSE – Check/Solution DISPLAY An installer is required for most checks and solutions. SET REQUIRED) SENSOR/CONNECTION PROBLEM Check the sensor/PCB connection E00.44 DHW sensor open Check the operation of the temperature sensor Measurement of the ohmic value SENSOR/CONNECTION PROBLEM Check the sensor/PCB connection...
Page 146
3 INSTRUCTIONS FOR THE INSTALLER PERMANENT ANOMALIES DESCRIPTION (RE CAUSE – Check/Solution DISPLAY An installer is required for most checks and solutions. SET REQUIRED) FLUE GAS SENSOR MALFUNCTION E04.04 Flue gas sensor short circuited Check the operation of the flue gas sensor Check the sensor/PCB connection SENSOR/CONNECTION PROBLEM E04.05...
Page 147
3 INSTRUCTIONS FOR THE INSTALLER PERMANENT ANOMALIES DESCRIPTION (RE CAUSE – Check/Solution DISPLAY An installer is required for most checks and solutions. SET REQUIRED) GAS VALVE Check/replace the gas valve wiring Check/replace the gas valve E04.23 Communication internal stoppage PCB ERROR Replace the PCB Switch the power supply off and on again and then RESET ELECTRODE PROBLEM...
3 INSTRUCTIONS FOR THE INSTALLER PERMANENT ANOMALIES DESCRIPTION (RE CAUSE – Check/Solution DISPLAY An installer is required for most checks and solutions. SET REQUIRED) GAS VALVE Check/replace the PCB E04.250 Gas valve fault Check/replace the gas valve Check/replace the gas valve wiring PCB ERROR E04.254 Unknown error...