Narvi Heat
ASENNUS- JA KÄYTTÖOHJE
FI
10,2 KW 11,9 KW 15,3 KW 20,4 KW 25,5 KW 30,6 KW 40,8 KW
INSTALLATION AND INSTRUCTION MANUAL
EN
10,2 kW 11,9 kW 15,3 kW 20,4 kW 25,5 kW 30,6 kW 40,8 kW
VERSIO 04/2025

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Heat and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NARVI Heat

  • Page 1 Narvi Heat ASENNUS- JA KÄYTTÖOHJE 10,2 KW 11,9 KW 15,3 KW 20,4 KW 25,5 KW 30,6 KW 40,8 KW INSTALLATION AND INSTRUCTION MANUAL 10,2 kW 11,9 kW 15,3 kW 20,4 kW 25,5 kW 30,6 kW 40,8 kW VERSIO 04/2025...
  • Page 2: Table Of Contents

    FI Sisällysluettelo 1. TEKNISET TIEDOT 2. ENNEN ASENNUSTA 3. SUOJAETÄISYYDET 4. ASENNUS 4.1 KIUKAAN ASENNUS 4.2 OHJAUSKESKUKSEN JA ANTURIEN ASENNUS 8 5. KIVIEN LADONTA 6. SAUNAN ILMANVAIHTO 7. SAUNAN RAKENNE 7.1 SUOJAKAIDE 8. TÄRKEÄT LISÄOHJEET 9. HUOLTO-OHJEET 10. VARAOSAT 11. KYTKENTÄKAAVIOT JA VIRRANSYÖTTÖ EN Content 1.
  • Page 4: Tekniset Tiedot

    1375 mm 815 mm 105,5 kg 160 kg 36 – 46 m³ Narvi Heat -kiukaiden materiaalit ovat pääosin asetetut standardit ja määräykset. Ohjaus- HST-terästä (AISI 316) ja lämmitysvastukset keskuksen on oltava varustettu ulkopuolisella (Incoloy) tulenkestävää terästä. lämpötila-anturilla (ts. termostaatilla) ja turvalait- teilla (ts.
  • Page 5: Ennen Asennusta

    0,8 kW / 1 m³. tilausta. – Kiuasta ei saa asentaa syvennykseen, eikä kiu- – Tarkista taulukosta 1, että Narvi Heat -laitos- kaan ympärille saa tehdä umpinaista suojausta. sähkökiukaan ja Narvi Logi -ohjauskeskuksen – Varmista, että löylyhuoneen korkeus on suu- ja -lisäohjauskeskuksen koko (A) on oikea ja...
  • Page 6 Löylyhuone Teho Kiukaan minimisuojaetäisyydet Kaapelit kiukaiden Tilavuus Korkeus Sivulle Edessä Edessä Kattoon välissä A**) B**) C**) D**) E**) m³ m³ 2300 1490 10,2 2300 1490 2300 1490 11,9 2300 1490 2300 1490 15,3 2300 1490 20,4 2300 1490 25,5 2300 1490 30,6 2300...
  • Page 7: Suojaetäisyydet

    +98–138 – Kiukaan liittämisen sähköverkkoon saa suorittaa vain asennusoikeudet omaava sähköasentaja - Narvi Heat -asennusalustan korkeus säädettä- voimassa olevien määräysten mukaan. vissä säätöjaloilla 40 mm. – Kytkentäkaaviot ovat esitetty tämän ohjeen –...
  • Page 8: Ohjauskeskuksen Ja Anturien Asennus

    Näin suojarasvat saadaan poltetuksi pois kiukaasta. Varmista riittävä tuuletus mahdollis- ten käryjen poistamiseksi. – Anna kiukaan jäähtyä ennen kivien ladontaa. Kuva 2. – Käytä aina Kerkes-kiuaskiviä Narvi Heat -laitos- sähkökiukaissa (katso erilliset takuuehdot). Kerkes kiuaskivien ladonta: – Kerkes-kiuaskiviä ei tarvitse pestä ensi ladonnassa.
  • Page 9: Saunan Ilmanvaihto

    Teho kiukaaseen lähetettvä (mm) määrä (kg) määrä (kg) määrä (kg) (kg) määrä (kg) Narvi Heat 10,2 kW 10,2 kW 60 mm 30 (40) *) Narvi Heat 11,9 kW 11,9 kW 60 mm Narvi Heat 15,3 kW 15,3 kW 60 mm...
  • Page 10: Huolto-Ohjeet

    Narvi Heatien Incoloy-vastuksien vaihto-ohjeet saa tilaamalla ne Narvilta (myynti@narvi.fi). 9. HUOLTO-OHJEET – Narvi Heat -laitossähkökiukaille on tehty ensi- huolto tehtaalla jo ennen toimitusta asiakkaalle. 10. VARAOSAT – Takuun voimassa olon edellytys on, että huol- –...
  • Page 12: Technical Data

    Narvi Heat sauna heaters. 60335-2-53. In case other controller than Narvi Logi is used, If the Narvi Heat electrical heater is used in a the controller must meet the current general public sauna with a controller that does not have a standards and regulations and those specifically timer;...
  • Page 13: Before Installation

    – Make sure that the height of the sauna room is correct size (A). greater than the minimum height specified in – Ensure from table 2 that the power of the Narvi Table 2 and that the specified minimum safety Heat sauna heater is suitable for the sauna in distances are met.
  • Page 14 Sauna room Effect Minimal safety clearances to the heater Cables between Volume Height on the sides at the front at the front to the ceiling heaters A**) B**) C**) D**) E**) m³ m³ 2300 1490 10,2 2300 1490 2300 1490 11,9 2300 1490...
  • Page 15: Safety Distances

    120 mm from the heater. A guardrail made of non-combustible – For Narvi Heat electrical heaters, it is recom- material must also be open in structure and mended to always install two supply cables from maintain a safety distance of 50 mm.
  • Page 16: Installation Of The Controller And Sensors

    – Wear protective gloves when placing stones. regulations and the manufacturer’s installation instructions. – Note. It is recommended to heat up the device until the heating elements are glowing, in order – Leakage may occur during the insulation to burn off the protective grease. Ensure suffi- resistance measurement of the heater due to cient ventilation to remove any fumes.
  • Page 17 Effect stones to Ø (mm) quantities (kg) quantity (kg) quantity (kg) quantity (kg) heater (kg) Narvi Heat 10,2 kW 10,2 kW 60 mm 30 (40) *) Narvi Heat 11,9 kW 11,9 kW 60 mm Narvi Heat 15,3 kW 15,3 kW...
  • Page 18: Ventilation Of The Steam Room

    – Outer casing made of acid-resistant steel may – The protective barrier must be open in change its color because of the heat, which is structure. normal behavior for the material. Color changes are not covered by the warranty.
  • Page 19: Maintenance Instructions

    – The warranty is valid only if the maintenance according to the maintenance program is carried out properly and on time. – For Narvi Heat electrical heaters, the mainte- nance tasks are as follows: - Swimming halls every 6 kk months...
  • Page 20: Kytkentäkaaviot Ja Virransyöttö

    11. KYTKENTÄKAAVIOT JA VIRRANSYÖTTÖ/ CONNECTION SCHEMES AND POWER SUPPLY...
  • Page 28 Narvi Oy Yrittäjäntie 1 27230 Lappi, Finland Tel. +358 207 416 740 www.narvi.fi...