Download Print this page

Advertisement

Available languages

Available languages

Quick Links

OCS4-10 / OSD4-1999 / OSA4-10
Contents
Introduction ...................................................2
First time settings .........................................2
CS4
CENTRAL CONTROLLER
TM
General operation .........................................2
Back ...........................................................2
Exit .............................................................2
Operation mode ............................................2
Holiday mode ............................................2
Comfort mode ...........................................3
Frost mode .................................................3
Manual mode .............................................3
Auto mode ..................................................3
Controller setup menus ...............................3
4-event settings ............................................3
Schedule ....................................................3
User settings .................................................3
Time and date ...........................................3
Child lock ..................................................3
Display settings .........................................3
Energy monitor ..........................................4
Engineer settings ..........................................4
Offset temperature .....................................4
Adaptive function .......................................4
Comfort System4
Menu
TM
List
4-event settings
GREEN COMFORT
Máximo conforto com reduzido consumo de energia
Application .................................................4
Temperature scale ......................................4
Frost temperature .......................................4
Backlight ....................................................4
Sensor selection .........................................4
Language....................................................5
Factory reset ...............................................5
Information .................................................5
System settings ............................................5
Add unit ......................................................5
Remove unit ...............................................5
Switch unit ..................................................5
Alarm relay ..................................................5
Readout .........................................................5
Energy monitor ...........................................5
Room status ...............................................5
Back ...........................................................5
Exit .............................................................5
Control signal .............................................5
Factory settings, Master .............................6
CS4
THERMOSTAT
TM
General operation .........................................6
Wireless signal strength ..............................6
16:31
Tue
00: Hall
21.0°C
List
Menu
Menu
User settings
Engineer settings
Time and date
Offset temp.
Child lock
Adaptive function
Display settings
Application
Energy monitor
Temp scale
Back
Backlight
Exit
Sensor
Language
Factory reset
Information
Back
Exit
© 2013 OJ Electronics A/S
U S E R M A N U A L
Comfort System4
Manual temperature setting ........................6
Settings .........................................................6
Max. temperature .......................................6
Min. temperature ........................................6
Max. limit temperature ...............................6
Min. limit temperature ................................6
Measured floor temperature .......................6
Measured room temperature......................6
Application .................................................6
Offset ..........................................................7
Backlight ....................................................7
Address readout .........................................7
Repeater function .......................................7
Software version ........................................7
Child lock (local) ...........................................7
Factory reset .................................................7
CS4
TM
PANEL HEATER CONTROLLER
General operation .........................................7
LED readouts ................................................7
Factory setting ...........................................7
COMFORT System4
Error messages ............................................7
System factory settings ...............................8
Preset schedule ..........................................8
Mode
System settings
Readout
Add unit
Energy monitor
Remove unit
Room status
Switch unit
Back
Alarm relay
Exit
Back
Exit
TM
English
, GENERAL
TM
Mode
Exit
Holiday
Comfort
Frost
Manual
Back
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Comfort System4 MCS4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for OJ Electronics Comfort System4 MCS4

  • Page 1 Display settings Application Switch unit Back Manual Energy monitor Temp scale Alarm relay Exit Back Back Backlight Back Exit Sensor Exit Language Factory reset Information Back Exit © 2013 OJ Electronics A/S GREEN COMFORT Máximo conforto com reduzido consumo de energia...
  • Page 2: Central Controller

    Up to 5 area The comfort system is now in Holiday mode and a suitcase is names can be chosen. displayed. When the specified date and time is reached, the Central © 2013 OJ Electronics A/S...
  • Page 3: User Settings

    3. Use the Up or Down button to choose the days for which you Temp -  want to change the settings: Mon-Fri or Sat-Sun for 5:2; Mon- -Set temp: Shows the current temperature  setting © 2013 OJ Electronics A/S...
  • Page 4: Engineer Settings

    Floor sensors of types other than that sup- Press OK and enter the measured temperature value. Confirm with plied by OJ Electronics (12 kΩ/ 25°C) can Sensor be selected in this menu. The controller is ...
  • Page 5: System Settings

    Use Back to return to the previous step.   select the required zone. Exit Confirm with OK. Exit Returns to the initial display. Control signal OCS4 is equipped with a control signal input, the terminal for © 2013 OJ Electronics A/S...
  • Page 6 Central Controller has been lost. Go to System settings / Add unit on the Central Controller to reconnect the thermostat. Application setup for the thermostat. Allows the type of control to be set. There are 4 options: © 2013 OJ Electronics A/S...
  • Page 7 E0: Internal failure. The thermostat is defective. Replace unit. Power interrupter E1: Internal sensor defective or short-circuited. E2: External sensor defective or short-circuited. E5: Internal overheating. Inspect the installation. E6: Communication error. No connection to Central Controller. Green LED Red LED © 2013 OJ Electronics A/S...
  • Page 8 OJ ELECTRONICS A/S Stenager 13B · DK-6400 Sønderborg Tel.: +45 73 12 13 14 · Fax +45 73 12 13 13 oj@ojelectronics.com · www.ojelectronics.com The OJ trademark is a registered trademark belonging to OJ Electronics A/S · © 2013 OJ Electronics A/S...
  • Page 9 Application Switch unit Back Manual Energy monitor Temp scale Alarm relay Exit Back Back Backlight Back Exit Sensor Exit Language Factory reset Information Back Exit GREEN COMFORT © 2013 OJ Electronics A/S Máximo confort con un bajo consumo de energía...
  • Page 10: Ajustes Iniciales

    • Las unidades conectadas ya pueden agruparse en un nombre presione OK. Seleccione la temperatura de vacaciones y confirme de área o número de zona en el controlador. Pueden elegirse con OK. hasta 5 nombres de área. © 2013 OJ Electronics A/S...
  • Page 11  bajo Factory settings (Ajustes de fábrica).  los ajustes. Hay cuatro ajustes alternativos de bloqueo para niños: El programa se puede cambiar fácilmente de Central : Bloquea solamente el controlador. la manera siguiente: © 2013 OJ Electronics A/S...
  • Page 12 Readout (Lectura). de estos límites en los modos automático, confort y manual. Pulse OK para resaltar la temperatura Mín. Use el botón de flecha Arriba o Abajo para seleccionar la temperatura mínima permisible. © 2013 OJ Electronics A/S...
  • Page 13 Para retirar un Termostato o Controlador de Remove unit sensores de suelo de tipos distintos de los Panel Calefactor del Sistema de Confort, pulse  suministrados por OJ Electronics (12 kΩ/  OK. Seleccione la unidad que desea retirar y  ...
  • Page 14: Funcionamiento General

    El ajuste manual se aplicará hasta el próximo evento programado. Establezca la temperatura deseada usando los botones izquierdo y derecho. El ajuste de temperatura destellará en la pantalla. 5 segun- © 2013 OJ Electronics A/S...
  • Page 15 Indicación de la temperatura real del suelo (si está conectado un sensor de suelo). Temperatura de habitación Indicación de la temperatura de habitación real actual. Aplicación Configuración de la aplicación para el termostato. Permite definir el tipo de control. Existen 4 opciones: © 2013 OJ Electronics A/S...
  • Page 16 Retire la tapa insertando un pequeño destornillador en el orificio a un lado del termostato. Presione la almohadilla de presión central bajo los LEDs con el destornillador. Ambos LEDs destellarán dos veces. El punto del relé ha sido restablecido. © 2013 OJ Electronics A/S...
  • Page 17 OJ ELECTRONICS A/S Stenager 13B · DK-6400 Sønderborg Tel.: +45 73 12 13 14 · Fax +45 73 12 13 13 oj@ojelectronics.com · www.ojelectronics.com La marca es una marca comercial registrada de OJ Electronics A/S · © 2013 OJ Electronics A/S...
  • Page 18 © 2013 OJ Electronics A/S...
  • Page 19 © 2013 OJ Electronics A/S...
  • Page 20 OJ ELECTRONICS A/S Stenager 13B · DK-6400 Sønderborg Tel.: +45 73 12 13 14 · Fax +45 73 12 13 13 oj@ojelectronics.com · www.ojelectronics.com The OJ trademark is a registered trademark belonging to OJ Electronics A/S · © 2013 OJ Electronics A/S...