Dell PowerEdge R210 Hardware Owner's Manual page 23

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R210:
Table of Contents

Advertisement

Message
Maximum rank
count exceeded.
The following
DIMM has been
disabled: x
Memory address
line failure at
address, read
value expecting
value.
Memory double
word logic
failure at
address, read
value expecting
value.
Memory
Initialization
Warning: Memory
size may be
reduced.
Memory odd/even
logic failure at
address, read
value expecting
value.
Memory
write/read
failure at
address, read
value expecting
value.
Causes
Invalid memory
configuration. The system
will run but with the
specified memory module
disabled.
Faulty or improperly
installed memory modules.
Faulty or improperly
installed memory modules.
Invalid memory
configuration. The system
will run but with less
memory than is physically
available.
Faulty or improperly
installed memory modules.
Faulty or improperly
installed memory modules.
Corrective Actions
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 79.
See "Troubleshooting System
Memory" on page 116.
See "Troubleshooting System
Memory" on page 116.
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 79.
See "Troubleshooting System
Memory" on page 116.
See "Troubleshooting System
Memory" on page 116.
About Your System
25

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PowerEdge R210 and is the answer not in the manual?

This manual is also suitable for:

External oemr r210

Table of Contents

Save PDF