QUICK INSTALLATION GUIDE
SMILE-G3-T12-INV / SMILE-G3-T15-INV / SMILE-G3-T20-INV
01
Product Overview
(1) Grounding Points
(2) Communication Ports
(3) Wi-Fi Port
(4) Battery Circuit Breaker
(5) BAT - Connector
(6) BAT + Connector
(7) PV + Connectors / PV - Connectors
(8) PV Switch
(9) Backup Connector
(10) Grid Connector
(11) Parallel Communication Ports (Reserve)
(12) LED/LCD Display
02
Accessories and Installation Tools
2.1 Scope of Delivery
Positioning
Inverter (×1)
Wall Bracket (×1)
Plate (×1)
Grid Connector
Backup
PV+&PV-
Connector (×1)
Connectors (×3)
(×1)
COM Connection
AUX Terminal
Grounding Cable
Cover (×1)
Block (×2)
(×1)
Grounding Cable
Communication
Power Cable
between two
Cable between two
between
Column Series
Column Series
two Column Series
Batteries * (×1)
Batteries * (×1)
Batteries * (×1)
* : optional, suitable for series batteries.
4.2 AC Connection
Select a suitable circuit breaker and consider the factors influencing the ampacity of the cable: type of
cable used, ambient temperature around the cable, type of cable routing, bundling of cables. Other
influences on dimensioning: loop impedance, mutual heating of circuit breakers, ambient temperature
at the circuit breaker, selectivity, type of connected device. If these factors are ignored, it increases
the danger of the circuit breaker tripping under normal operating conditions.
AC connection recommendation for SMILE-G3-T12-INV
Description
Max. Current
Recommended AC Circuit Breaker Type
24.6A
40A
Grid Side
Backup Side
21.7A
32A
AC connection recommendation for SMILE-G3-T15-INV
Recommended AC Circuit Breaker Type
Description
Max. Current
29A
Grid Side
50A
Backup Side
27.2A
40A
AC connection recommendation for SMILE-G3-T20-INV
Description
Max. Current
Recommended AC Circuit Breaker Type
36.2A
Grid Side
50A
36.2A
50A
Backup Side
Grid and Backup Connection
1
2
4~10mm²
Φ11~26mm
12mm
75~80mm
4
5
1.3Nm
(1)
(11)
(10)
(2)
(9)
(3)
(4)
(5)
(6)
(7)
(8)
(1)
Right Cover (×1)
Cable Cover (×1)
Hexagon Head
Wi-Fi Module
Large Washer
(×1)
Screw M5*12 (×3)
Communication
Cable between
Series Battery
Inverter and
Main Negative
1st Series Battery *
Power Cable * (×1)
(×1)
System Wiring
Quick Installation
Diagram (×1)
Guide (×1)
Recommend cable cross section
6~10mm²
6~10mm²
Recommend cable cross section
6~10mm²
6~10mm²
Recommend cable cross section
6~10mm²
6~10mm²
3
Φ19~26mm
6
7
PH2
V01
2.2 Installation Tools
T20×150mm
T20 Screwdriver
Crimping Pliers
(Model:PV-CZM-22100)
03
Mounting the Inverter
Before installing the inverter, please ensure that the battery has been installed properly.
1
Position and mark the
drilling location
(12)
04
Electrical Connection
You must protect each inverter with an individual grid/backup circuit breaker in order to ensure that the inverter
Top Cover (×1)
can be disconnected safely.
Before doing electrical connection, please ensure the PV switch & all AC and DC circuit breakers are switched
OFF and cannot be reactivated.
Wall Anchor
(×6)
Please refer to System Wiring Diagram for detailed wiring.
4.1 Grounding Connection
Series Battery Main
Positive Power
Cable * (×1)
T20×150mm
2.5Nm
8-10mm
6-10mm²
01
02
8
Disassembling
1
/
1.2/PH2
≤1.5Nm
4.3 PV Connection
1
7mm
7mm
4-6mm2
4
If there are unused PV terminals, please
seal them with the caps.
4.4 BAT Power Connection
Danger to life due to burns caused by electric arcs through short-circuit currents.
Short-circuit currents in the battery can cause heat build-up and electric arcs. Heat build-up and electric arcs
may result in lethal injuries due to burns.
•Disconnect the battery from all voltages sources prior to performing any work on the battery.
•Disconnect the inverter from all voltages sources prior to performing any work on the inverter.
•DO NOT short-circuit the battery terminals. First, complete the main negative terminal connection between
battery and inverter, and then complete the main positive terminal connection between battery and inverter.
•Observe battery safety information provided in the Installation&Operation&Maintenance Manual.
03
04
Blade width:1.2/2.5
SW8
PH2×150mm
PH2 Screwdriver
Flat-Head Screwdriver
Socket Wrench
Cord End Terminal
Current Clamp
Spirit Level
Crimper
2
Secure the wall bracket
(X6)
②
①
SW8
Additional grounding
Grounding for
battery
9
2
2
Click
2.6-2.9Nm
Click
5
Click
Click
Network Plug
Wire Stripper
Clamp
Hammer Drill,
Multimeter
Bit φ10
3
Hang the inverter onto the
wall bracket
①
②
②
T20×150mm
2.5Nm
10
3
/
1.2/PH2
≤0.5Nm
3
Check the polarity of the PV strings
Check the open-circuit voltage of the PV
strings which should be less than 950V
6
+
-
+
-
+
-
Need help?
Do you have a question about the SMILE-G3-T12-INV and is the answer not in the manual?
Questions and answers