Summary of Contents for MAER IDROPULITRICI SITEMASTER 12/100

  • Page 1 High Pressure Cleaner SITEMASTER Instructions Manual Instructions for installation and use Manufactured by: MAER IDROPULITRICI SRL Via Torre 65/2 24050 Torre Pallavicina BG Tel 0039 0363 996579 Fax 0039 0363 996688 maer@maeridropulitrici.com www.maeridropulitrici.com ITALY...
  • Page 2: Table Of Contents

    Contents 1. Field of employment 2. Characteristics of the personnel employed to use the cleaner 3. Accidents prevention 4. Characteristics of the high pressure cleaner 5. Instruments of the high pressure cleaner 6. Transport and unpacking 7. Installation 8. Connection to the electricity supply 9.
  • Page 3: Field Of Employment

    INSTRUCTIONS MANUAL INSTRUCTIONS FOR INSTALLATION AND USE Congratulations! By purchasing a MAER high pressure cleaner, you have purchased a high technology machine that will allow you to realize, for a long time, washing operations with care, versatility and safety. The customer and buyer must verify that the operators have read and know the content of the manual and that, therefore, attentively and meticulously follow all the indications.
  • Page 4: Accidents Prevention

    3. Accidents prevention 3.1. The instructions furnished in this manual don’t replace in any way the norms related to the safety, to the installation and the use, to the technical data or the norms in force in the nation of installation or use or the norms dictated of the common sense.
  • Page 5: Characteristics Of The High Pressure Cleaner

    -Water float -Electric controls 24V -Frost protection -Timed total stop system DSS 3.18. The high pressure cleaner SITEMASTER is provided with a timed total stop system. If the pistol remains closed for more than 10 sec., the motor will stop. The motor will start again by opening the pistol. In addition the machine will stop after 10 false starts (due to micro-leaks) or after 60 minutes without use.
  • Page 6: Instruments Of The High Pressure Cleaner

    5. Instruments of the high pressure cleaner Q1: Burner switch Q2: ON/OFF switch H1: Green light (power supply on) H2: Red light (alarms) H3: Orange light (burner) K1: Boiler thermostat K4: Frost protection thermostat MA: Pressure gauge RD: Detergent adjustment tap FD: Detergent suction hose SG: Gasoil tank H1 H2...
  • Page 7: Transport And Unpacking

    6. Transport and unpacking 6.1. Submit lifting and transport to specialized personnel. Protect the machine, especially during transports on road, from bumps, damps or from vibrations, etc…; to underline the dangerousness in the moving of the suspended loads, operators must be warned about risks of collisions. 6.2.
  • Page 8: Connection To The Water Supply

    9. Connection to the water supply 9.1. The pressure of the water supply must be at least 2 bar. 9.2. The water supply must provide a flow of water of at least of the 10% of the course of the high pressure cleaner (compare the chart with technical characteristics).
  • Page 9: Maintenance

    13. Maintenance 13.1. It is absolutely forbidden to effect controls or operations of maintenance with the machine operating or under tension: always remove the electricity supply!!! Don’t even effect reparations of fortune or precarious, and never use not-original spare parts. 13.2.
  • Page 10: Electrodes

    II of the legislative decree 22/97. 18.3. ATTENTION: MAER IDROPULITRICI society does not assume any responsibility for damages to things, personal or animals, consequential and consequent to the re-use of the single parts or the single components of the machine for function or situation of the assemblage different from the original for which the high pressure cleaner has been conceived.
  • Page 11: Problems During The Operation

    19. Problems during the operation Problem Cause Solution The inlet hoses vibrate Foreign piece in a valve Disassemble the valve and remove the foreign piece Air suction. Identify the source of the air suction and eliminate it The burner does not switch on thermostat Insert adjust...
  • Page 12: Hydraulic Plan

    20. Hydraulic plan Water tank with float Water inlet hose Flow adjustment tap Delivery hose Burner pressure switch Pump Motor Detergent tap Detergent inlet hose 10) Tank 11) Filter 12) Nozzle 13) Microswitch 14) By-pass valve 15) By pass hose 16) Pressure gauge 17) Fuel return hose 18) Fuel inlet hose...
  • Page 13: Warranty

    21. Warranty 21.1 The High pressure cleaner has a twelve-month warranty from the date of delivery. Defects and vices connected or consequent to not compliance with the indications contained in this manual ARE EXCLUDED FROM THE WARRANTY. 21.2 MAER Guarantees the mechanical parts of the machine, under normal conditions of use and service; this warranty does not include accessories and usage materials.
  • Page 14: Safety Rules / Residual Risks

    The machine you purchased is a technologically advanced product which uses a high pressure pump. The machine must be used by people with a specific education and competences on high pressure cleaners. To obtain more safety, read this booklet carefully and follow the instructions each time you use the machine.
  • Page 15 1.2 SAFETY “MUSTS” 1.2.1. All electrical conductors MUST BE PROTECTED against the water jet. SHORT CIRCUIT HAZARD. 1.2.2. The machine MUST ONLY BE CONNECTED to an adequate power supply in compliance with all applicable regulations (IEC 60364-1). The machine may cause network noise during startup. Use of a safety residual current circuit-breaker (R.C.C.B.) will provide additional protection for the operator (30 mA).
  • Page 16: Declaration Of Conformity

    - EN 292-1 / EN 292-2 / EN 60204-1 / EN 60335-2-79 / EN 60335-10 as described in the technical dossier, in the instructions manual for the use and the maintenance. The technical dossier is filed at MAER IDROPULITRICI company. Torre Pallavicina,...