Metal Work Pneumatic FLUX IO-Link User Manual

Digital flowmeter and pressure sensor

Advertisement

Available languages

Available languages

Quick Links

FLUX IO-Link
DIGITALER DURCHFLUSSMESSER UND DRUCKSENSOR
BEDIENUNGANLEITUNG
FLUX IO-Link
DIGITAL FLOWMETER AND PRESSURE SENSOR
USER MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLUX IO-Link and is the answer not in the manual?

Questions and answers

Summary of Contents for Metal Work Pneumatic FLUX IO-Link

  • Page 1 FLUX IO-Link DIGITALER DURCHFLUSSMESSER UND DRUCKSENSOR BEDIENUNGANLEITUNG FLUX IO-Link DIGITAL FLOWMETER AND PRESSURE SENSOR USER MANUAL...
  • Page 2: Bestimmungsgemäßer Gebrauch

    FLUX IO-Link ist eine Steuereinheit zur Messung aller relevanten Daten des betreffenden Mediums. Sie entspricht den IO-Link-Spezifikationen, bietet erweiterte Diagnosen und ermöglicht die Verbindung zu einem IO-Link-Master. Sie unterstützt die COM3-Kommunikation gemäß der V1.1-Spezifikation und den Anschluss über einen Port der Klasse A.
  • Page 3: Installation

    1. INSTALLATION 1.1 PNEUMATISCHER ANSCHLUSS Der pneumatische Anschluss erfolgt über die Gewindebohrungen im Gehäuse. • Installieren Sie das Gerät gemäß dem Pfeil, der die Strömungsrichtung der Luft anzeigt. • Verwenden Sie für den Anschluss der Einlassseite ein gerades Rohr mit einer Mindestlänge gemäß der Tabelle. Ohne Beruhigungstrecke kann die Genauigkeit von den angegebenen Werten abweichen.
  • Page 4 1.2 INTEGRATION MIT KOMPONENTEN DER Syntesi®-PRODUKTREIHE Die FLUX kann mit Syntesi®-Komponenten ergänzt werden: • FLUX 1 mit Syntesi® Größe 1; • FLUX 2 mit Syntesi® Größe 2. Um die angegebene Messgenauigkeit zu gewährleisten und zu verhindern, dass Schmiermittelrückstände den Messsensor beschädigen, muss ein Filter am FLUX-Einlass installiert werden. Wenn das Gerät mit einem Syntesi®-Filter ausgestattet ist, muss im Systemmenü...
  • Page 5 1.3 VERDRAHTUNG Ein 5-poliger M12-Stecker, A-Code, wird für den elektrischen Anschluss verwendet und muss mit einem IO-Link-Master verbunden werden. Die Stromversorgung erfolgt direkt über den Master. Anschluss an das IO-Link-Netzwerk Beschreibung M12-Stecker, A-kodiert Signal Leiterfarbe Port Class A Port Class A +24VDC Stromversorgung Braun 1 = L+...
  • Page 6 3. MENÜZUGRIFF (NUR FÜR MODELLE MIT DISPLAY) Parametereinstellung Drücken Sie die SET-UP-Tasten gleichzeitig für 1 Sekunde, um auf die Parametereinstellungen zuzugreifen. Verwenden Sie die vertikalen Pfeiltasten, um die Funktion auszuwählen. Drücken Sie die rechte Pfeiltaste, um auf die Funktionsparameter zuzugreifen. Verwenden Sie die vertikalen Pfeiltasten, um den Parameter zu ändern.
  • Page 7 DURCHFLUSS / DRUCK DIGITALER AUSGANGSMODUS NORMALLY CLOSED – NC MODUS DIGITALER AUSGANG NORMALLY OPEN – NO Modus Flussmengenschalter mit Hysterese Modus Flussmengenschalter mit Hysterese Modus Bandbreitenschalter Modus Bandbreitenschalter VOLUMENVERBRAUCH MODUS DIGITALER AUSGANG NORMALLY OPEN – NO DIGITALER AUSGANGSMODUS NORMALLY CLOSED – NC Modus Volumenverbrauch Modus Volumenverbrauch MODUS AUSGANG ZYKLISCHER IMPULS...
  • Page 8 3.3. DISPLAY Es ist möglich, das Display um 90°, 180° oder 270° zu drehen, um es an die Montageposition anzupassen, indem die beiden durch das Symbol angegebenen Tasten für 1 Sekunde gedrückt werden. 3.3.1 PARAMETER • Sprache: Italiano, English, Deutsch, Français, Español. •...
  • Page 9 PLANT PLANT SETUP FILTER SYS FILTER SYS PLANT GAS TYPE ARIA GAS TYPE ARIA K ENERGY K ENERGY DISPLAY SERVICE INFO PLANT PLANT FILTER SYS FILTER SYS GAS TYPE ARIA GAS TYPE ARIA K ENERGY K ENERGY HELIUM NITROGEN PLANT PLANT FILTER SYS FILTER SYS...
  • Page 10 SETUP PLANT DISPLAY SERVICE INFO DIGITAL OUTPUT SETTINGS SETTINGS DIGITAL OUTPUT SETTINGS CONTACT TYPE N.O. CONTACT TYPE N.O. THRESHOLD REFERENCE FLOW REFERENCE FLOW N.O. N.C. SETTINGS SETTINGS CONTACT TYPE CONTACT TYPE REFERENCE FLOW REFERENCE FLOW FLOW FLOW PRESSURE VOLUME CONSUMPTION...
  • Page 11 SCHWELLENWERT - DURCHFLUSS DIGITAL OUTPUT THRESHOLD THRESHOLD - DRUCK SETTINGS FUNCTION SWITCH FUNCTION SWITCH THRESHOLD T. SET/HI T. SET/HI T. RES/LO . T. RES/LO . SWITCH LIVELLO LEVEL SWITCH RANGE SWITCH THRESHOLD THRESHOLD FUNCTION SWITCH FUNCTION SWITCH T. SET/HI T. SET/HI T.
  • Page 12 DISPLAY DISPLAY SETUP LANGUAGE LANGUAGE PLANT FLOW UNIT Nl/min FLOW UNIT Nl/min PRESSURE UNIT PRESSURE UNIT DISPLAY SET FL.COL 2000 SET FL.COL 2000 SERVICE RES FL.COL 2000 RES FL.COL 2000 INFO DISPLAY DISPLAY LANGUAGE LANGUAGE FLOW UNIT Nl/min FLOW UNIT Nl/min PRESSURE UNIT PRESSURE UNIT...
  • Page 13 SERVICE SETUP CONSUMPT. RESET CONSUMPT. RESET CONSUMPT. RESET PLANT CHARTS RESET SENSOR CHECK. Reset Done DISPLAY INTERNAL TEMP. consumptions? SERVICE PASSWORD INFO FACTORY RESET SERVICE CONSUMPT. RESET CHARTS RESET CHARTS RESET CHARTS RESET SENSOR CHECK. Reset Done INTERNAL TEMP. charts? PASSWORD FACTORY RESET SERVICE...
  • Page 14 With password disable PASSWORD PASSWORD PASSWORD PASSWORD PASSWORD ENABLE ENABLE DISABLE DISABLE DISABLE SERVICE SET PASSWORD SET PASSWORD SET PASSWORD Enable CONSUMPT. RESET password:000 password? CHARTS RESET SENSOR CHECK. INTERNAL TEMP. With password enable PASSWORD PASSWORD PASSWORD PASSWORD PASSWORD FACTORY RESET CONSUMPT.
  • Page 15 INSTALLATION DER FLUX IO-Link IN EINEM IO-Link-NETZWERK 5.1 IODD-KONFIGURATIONSDATEI Die entsprechende „MetalWork-FLUX-_ _ _ _ _ _ _ _ _-IODD1 1“-Konfigurationsdatei, die auf der Metal Work-Website verfügbar ist, wird mit der FLUX IO-Link geliefert. 5.2 ADRESSIERUNG 5.2.1 Zyklische Daten • 4 Eingangsbytes für den gemessenen Durchfluss [Nl/h] •...
  • Page 16 5.2.3 Konfiguration der Parameter vom IO-Link Master Parameter Index Subindex Beschreibung Datentyp 0 = Nl_min R/W 1 byte Anzeige - Maßeinheit der Durchflussrate 1 = Nl_h 2 = Nm _min 3 = Nm 4 = ft /min 5 = ft Art des MEDIUMS 0 = Air R/W 1 byte...
  • Page 17 6. DIAGNOSE DES IO-Link KNOTENS LED STATE BEDEUTUNG Keine Stromversorgung, Gerät ausgeschaltet ON (grün) Gerät wird ordnungsgemäß mit Strom versorgt Blinkend Gerätestörung. Stromversorgung außerhalb des zulässigen (grün) Bereichs; defekter Sensor. LED DIAG BEDEUTUNG ON (grün) Betriebszustand Blinkend Vorbetriebszustand (grün) ON (rot) IO-Link Kommunikationsfehler Blinkend Stromversorgungsfehler IO-Link...
  • Page 18 8. TECHNISCHE DATEN FLUX 1 FLUX 2 FLUX 3 FLUX 4 Nl/min 0 bis 2000 0 bis 4000 0 bis 8000 0 bis 15000 Durchflussmessbereich Druckluft (ölfrei) und neutrale Gase Medium °C Medientemperatur 0 bis 50 Durchflussrichtung unidirektional Messverfahren thermisch Arbeitsdruckbereich 0 bis 10 0 bis 1...
  • Page 19 s WICHTIG! Eine Spannung von mehr als 32VDC beschädigt das System irreversibel n In der Ausführung mit Druckmessumformer ● Genauigkeit bezogen auf Druckluft, bei einem Druck von 5 bar und einer Medientemperatur von 25°±10°C ✱ Um die angegebene Messgenauigkeit zu gewährleisten und um zu verhindern, dass Schmiermittelrückstande die Sensorik beschädigen, muss versorgungseitig ein Filter montiert werden.
  • Page 20: Intended Use

    FLUX IO-Link is a control unit for measuring all significant data of the gas concerned. Compliant with IO-Link specifications, it offers advanced diagnostics and provides connection to an IO-Link Master. It supports COM3 communication, in accordance with V1.1 specification and Class A Port connection.
  • Page 21: Installation

    1. INSTALLATION 1.1 PNEUMATIC CONNECTION Pneumatic connection is via the threaded holes in the body. • Install the device following the arrow indicating the direction of the air flow. • To connect the inlet side, use a straight pipe with a minimum length as per the table. If straight piping is not installed, the accuracy may vary from what is stated.
  • Page 22 1.2 INTEGRATION WITH COMPONENTS IN THE Syntesi PRODUCT RANGE ® FLUX can be supplemented with Syntesi component parts: ® • FLUX 1 with Syntesi size 1; ® • FLUX 2 with Syntesi size 2. ® In order to guarantee the stated measurement accuracy and to prevent lubricant residues from damaging the measurement sensor, a filter has to be mounted at the FLUX inlet.
  • Page 23: Electrical Connection

    1.3 ELECTRICAL CONNECTION A 5-pin M12 Code A connector is used for the electrical connection and must be connected to an IO-Link Master. Power is supplied directly via the Master. Connection to the IO-Link network Description of M12 male connector, A encoding Signal Lead colour Port Class A...
  • Page 24 3. MENU ACCESS (ONLY FOR MODELS WITH DISPLAY) Parameter setting Press the SET UP buttons simultaneously for 1 second to access the parameter settings. Use the vertical arrow keys to select the function. Press the right arrow key to access the function parameters. Use the vertical arrow keys to change the parameter.
  • Page 25: Flow / Pressure

    FLOW / PRESSURE DIGITAL OUT MODE NORMALLY OPEN – NO DIGITAL OUT MODE NORMALLY CLOSED - NC Level switch mode with hysteresis Level switch mode with hysteresis Band switch mode Band switch mode VOLUME CONSUMPTION DIGITAL OUT MODE NORMALLY OPEN – NO DIGITAL OUT MODE NORMALLY CLOSED - NC Volume consumption mode Volume consumption mode...
  • Page 26 3.3. DISPLAY Is possible to rotate the display by 90°, 180° or 270° to adapt it to the mounting position, by pressing the two keys indicated by the icon for 1 second. 3.3.1 PARAMETERS • Language: Italiano, English, Deutsch, Français, Español. •...
  • Page 27 PLANT PLANT SETUP FILTER SYS FILTER SYS PLANT GAS TYPE ARIA GAS TYPE ARIA K ENERGY K ENERGY DISPLAY SERVICE INFO PLANT PLANT FILTER SYS FILTER SYS GAS TYPE ARIA GAS TYPE ARIA K ENERGY K ENERGY HELIUM NITROGEN PLANT PLANT FILTER SYS FILTER SYS...
  • Page 28 SETUP PLANT DISPLAY SERVICE INFO DIGITAL OUTPUT SETTINGS SETTINGS DIGITAL OUTPUT SETTINGS CONTACT TYPE N.O. CONTACT TYPE N.O. THRESHOLD REFERENCE FLOW REFERENCE FLOW N.O. N.C. SETTINGS SETTINGS CONTACT TYPE CONTACT TYPE REFERENCE FLOW REFERENCE FLOW FLOW FLOW PRESSURE VOLUME CONSUMPTION...
  • Page 29 THRESHOLD DIGITAL OUTPUT THRESHOLD THRESHOLD - FLOW SETTINGS FUNCTION SWITCH FUNCTION SWITCH - PRESSURE THRESHOLD T. SET/HI P. T. SET/HI P. T. RES/LO P. T. RES/LO P. SWITCH LIVELLO LEVEL SWITCH RANGE SWITCH THRESHOLD THRESHOLD FUNCTION SWITCH FUNCTION SWITCH T. SET/HI P. T.
  • Page 30 DISPLAY DISPLAY SETUP LANGUAGE LANGUAGE PLANT FLOW UNIT Nl/min FLOW UNIT Nl/min PRESSURE UNIT PRESSURE UNIT DISPLAY SET FL.COL 2000 SET FL.COL 2000 SERVICE RES FL.COL 2000 RES FL.COL 2000 INFO DISPLAY DISPLAY LANGUAGE LANGUAGE FLOW UNIT Nl/min FLOW UNIT Nl/min PRESSURE UNIT PRESSURE UNIT...
  • Page 31 SERVICE SETUP CONSUMPT. RESET CONSUMPT. RESET CONSUMPT. RESET PLANT CHARTS RESET SENSOR CHECK. Reset Done DISPLAY INTERNAL TEMP. consumptions? SERVICE PASSWORD INFO FACTORY RESET SERVICE CONSUMPT. RESET CHARTS RESET CHARTS RESET CHARTS RESET SENSOR CHECK. Reset Done INTERNAL TEMP. charts? PASSWORD FACTORY RESET SERVICE...
  • Page 32 With password disable PASSWORD PASSWORD PASSWORD PASSWORD PASSWORD ENABLE ENABLE DISABLE DISABLE DISABLE SERVICE SET PASSWORD SET PASSWORD SET PASSWORD Enable CONSUMPT. RESET password:000 password? CHARTS RESET SENSOR CHECK. INTERNAL TEMP. With password enable PASSWORD PASSWORD PASSWORD PASSWORD PASSWORD FACTORY RESET CONSUMPT.
  • Page 33 5. COMMISSIONING INSTALLING THE FLUX IO-Link in an IO-Link NETWORK 5.1 IODD CONFIGURATION FILE The corresponding “MetalWork-FLUX-_ _ _ _ _ _ _ _ _-IODD1 1” IODD configuration file available on the Metal Work website is supplied with the FLUX IO-Link.
  • Page 34 5.2.3 Configuration of parameters from Master IO-Link Parameter Index Subindex Description Data type Display - Flow rate unit of measurement 0 = Nl_min R/W 1 byte 1 = Nl_h 2 = Nm _min 3 = Nm 4 = ft /min 5 = ft GAS type 0 = Air...
  • Page 35: Diagnostics And Troubleshooting

    6. IO-Link NODE DIAGNOSTIC MODE LED STATE MEANING No power supply, device switched off ON (green) Device powered correctly Flashing Device malfunction. (green) Power supply out of range, faulty sensor. LED DIAG MEANING ON (green) Operating status Flashing Pre-operating status (green) ON (red) IO-Link communication error...
  • Page 36 8. TECHNICAL DATA FLUX 1 FLUX 2 FLUX 3 FLUX 4 Measured flow range Nl/min 0 to 2000 0 to 4000 0 to 8000 0 to 15000 Fluid Compressed air free of any lubricants and inert gases Fluid temperature °C 0 to 50 Direction of flow Unidirectional...
  • Page 37 s IMPORTANT! Voltage greater than 32VDC will damage the system irreparably. n In versions with pressure transducer. ● Accuracy referred to compressed air gas, at a pressure of 5 bar and a fluid temperature of 25°C ±10°C. ✱ In order to guarantee the stated measurement accuracy and to prevent lubricant residues from damaging the measurement sensor, a filter has to be mounted at the FLUX inlet.
  • Page 38 NOTES...
  • Page 39 NOTES...
  • Page 40 NOTES...
  • Page 41 Metal Work FluxUp BEDIENUNGSANLEITUNG Metal Work FluxUp USER MANUAL...
  • Page 42: Installation

    Die Metal Work FluxUp App kann für die Verbindung über Bluetooth zu den Metal Work Durchflussmessgeräten der FLUX 1-4-Serie mit drahtloser Schnittstelle verwendet werden, von Android-Smartphones und iOS. Mit der Metal Work FluxUp App können alle von der FLUX aufgezeichneten Daten angezeigt und alle Betriebseinstellungen in Echtzeit angepasst werden.
  • Page 43 2.2 NUTZUNG Starten Sie die App und scannen Sie nach Geräten beim ersten Start. Danach wird die App bei jedem Start versuchen, sich mit dem zuletzt verbundenen Gerät erneut zu verbinden. Wenn das Gerät verfügbar ist, drücken Sie bei einem Fehler die Schaltfläche "Wiederholen", um die Verbindung erneut herzustellen.
  • Page 44 2.3 DASHBOARD Die Dashboard-Seite zeigt die Messdaten in Echtzeit an. Die Maßeinheiten können im Einstellungsmenü eingegeben werden, unabhängig von den auf der FLUX eingestellten Einheiten. Die obere Leiste zeigt den Namen des verbundenen Geräts an. Die untere Leiste zeigt das Funktionsmenü an. 2.4 ZÄHLER Die Zähler-Seite zeigt die Werte von Volumen, Energie und Masse an, die seit dem letzten Zurücksetzen auf der FLUX gemessen wurden.
  • Page 45 2.5 DIAGRAMME Die Diagramm-Seite zeigt die Graphen der gespeicherten Durchfluss- und Druckwerte an. Jedes Mal wenn eine Verbindung hergestellt wird, werden die Druck- und Durchflussdaten, die von der FLUX gespeichert wurden, abgefragt. Durch Klicken auf die Schaltfläche „Neu laden“ wird das Diagramm aktualisiert. Die Auswahl der Visualisierungszeit ist möglich.
  • Page 46 2.6.1 WERK(-MEDIUM) Wird verwendet, um den Typ des verwendeten Mediums und den Koeffizienten für die Berechnung der verbrauchten Energie festzulegen. 2.6.2 I/O Wird verwendet, um die Betriebsparameter des digitalen Eingangs und Ausgangs festzulegen. IO-Link-Version...
  • Page 47 Analoge Version 2.6.3 DISPLAY Ermöglicht die Einstellung folgender Parameter: - Anzeigeausrichtung; - Sprache; - Maßeinheit der Durchflussrate; - Maßeinheit des Drucks; - Farbwechselwerte der Durchflussanzeige...
  • Page 48 2.6.4 DRAHTLOS(-Einstellungen) Kann verwendet werden, um die Parameter der drahtlosen Netzwerkverbindung festzulegen: - Aktivierung über die Serverselektion Für den METALWORK-Server sind die Parameter bereits eingestellt. Für den benutzerdefinierten Server müssen die folgenden Parameter festgelegt werden: SSID IP-Adresse MQTT 2.6.4.1 SSID - Name: Geben Sie den Namen des Netzwerks ein, mit dem Sie sich verbinden möchten.
  • Page 49 2.6.4.2 IP - DHCP: Die IP-Adresse wird vom DHCP-Server zugewiesen. - STATISCH: Die IP-Adresse wird dauerhaft zugewiesen. IP-Adresse: Setzen Sie die IP-Adresse des Geräts in derselben Netzwerkumgebung wie das Gateway. Adressmaske: Setzen Sie die Maske gemäß dem IP-Adressbereich im angegebenen Subnetz.
  • Page 50 2.6.4.4 INFO - MAC WIR: MAC-Adresse für das drahtlose Protokoll - MAC BLU: MAC-Adresse für die Verbindung über FluxUp - SW VER: Softwareversion der Funkkommunikationssoftware - Standort: Kann verwendet werden, um den Gerätenamen festzulegen, es sind 11 Zeichen erlaubt. 2.6.5 PASSWORT Die Passwort-Seite ermöglicht es, einen dreiziffrigen Entsperrcode festzulegen.
  • Page 51: Wartung

    2.6.6 WARTUNG Durch das Klicken auf die Schaltfläche „Verbrauch zurücksetzen“ werden die gespeicherten Werte von Volumen, Energie und Masse auf null zurückgesetzt. Durch das Klicken auf die Schaltfläche „Diagramme zurücksetzen“ werden die Diagramme zurückgesetzt. 2.7 INFO Die Info-Seite zeigt Geräteinformationen an: - Netzwerkstatus, Netzwerparameter (IP-Adresse, GATEWAY, DNS1, DNS2);...
  • Page 52: Drahtlose Verbindung

    3. DRAHTLOSE VERBINDUNG Mit der Wireless-Version der FLUX 1-4 können Sie eine Verbindung zu einem Wi-Fi-Netzwerk über einen Access Point oder Gateway herstellen, um alle gemessenen Medienwerte zu überwachen und zu sammeln. LINK-STRUKTUR MIT DEM METAL WORK GATEWAY Das Metal Work Gateway übernimmt die Sammlung, Formatierung und Analyse der Daten und zeigt sie auf einer im Browser anzeigbaren Webseite an.
  • Page 53 MERKMALE DER DRAHTLOSEN VERBINDUNG Gateway SSID_SECURITY keine oder WPA/WPA2/WPA3 SSID_NAME max 31 Zeichen SSID_KEY max 62 Zeichen IP statisch / DHCP Broker MQTT Verschlüsselung: keine, TLS 1.0, 1.1, 1.2 (require_certificate = false) BROKER IP ADDRESS BROKER IP PORT 1883,8883 Benutzerauthentifizierung (optional): AUTH_NAME max 8 Zeichen AUTH_KEY max 8 Zeichen Datenstruktur im MQTT-Format (JSON-Datenpaketstruktur)
  • Page 54 Beispiel-Dashboard...
  • Page 55 4. ZERTIFIZIERUNGEN Dieses Gerät enthält: FCC ID: XPYNINAW106 IC: 8595A-NINAW106 Die NINA-W15-Modulserie ist für die Verwendung in den folgenden Ländern/Regionen zertifiziert: • Europe (RED) • USA (FCC) • Canada (IC) • Japan (MIC) • Taiwan (NCC) • South Korea (KCC) •...
  • Page 56 NOTIZEN:...
  • Page 57 NOTIZEN:...
  • Page 58: Android Devices

    The Metal Work FluxUp App can be used for connection via Bluetooth to Metal Work flow meters in the FLUX 1 and 2 series with a wireless interface, from Android smartphone and iOS. With the Metal Work FluxUp App, you can view all data recorded by the FLUX and set all operating parameters in real time.
  • Page 59: Operation

    2.2 OPERATION Run the App and scan the devices the first time it is started. Afterwards, each time it is started, the App will attempt to reconnect to the last connected device. If the device is available, in case of an error, press the Retry button to connect again. To rescan, open the top left menu and select ‘Devices’, All previously associated devices will be displayed.
  • Page 60 2.3 DASHBOARD The dashboard page displays measurement data in real time. The units of measurement can be entered in the Setting menu, irrespective of the units set on the FLUX. The top bar displays the name of the device being connected. The bottom bar displays the function menu.
  • Page 61 2.5 CHARTS The Charts page displays the graphs of saved flow rate and pressure values. Each time a connection is made, the pressure and flow rate data saved by the FLUX are requested. By clicking on the Reload button, the chart will be updated. The selection of the visualization time is possible.
  • Page 62 2.6.1 PLANT Used to set the type of gas used and the coefficient for calculating the energy consumed. 2.6.2 I/O Used to set the operating parameters of the digital input and output. IO-Link version...
  • Page 63 Analogue version 2.6.3 DISPLAY Can be used to set: - display orientation; - language; - flow rate measuring unit; - pressure measuring unit; - flow rate display colour change values.
  • Page 64 2.6.4 WIRELESS Can be used to set wireless network connection parameters: - Enable via server selection For the METALWORK server, the parameters are already set. For the Custom server, the following parameters must be set: SSID IP address MQTT 2.6.4.1 SSID - Name: enter the name of the network you wish to connect to - By clicking on the icon to the right of the Name field, the available networks are displayed...
  • Page 65 2.6.4.2 IP - DHCP: the IP address is assigned by the DHCP server - STATIC: the IP address is assigned permanently IP address, set the IP address of the device in the same network class as the link Gateway. Address mask, Set the mask according to the IP address range in the given subnetwork. IP DNS 1 and 2, Set the DNS server address, visible in the properties of the Wi-Fi network in use.
  • Page 66 2.6.4.4 INFO - MAC WIR: MAC address for the Wireless protocol - MAC BLU: MAC address for connection via the FluxUp - SW VER: software version of the radio communication software - Location: can be used to set the device name, 11 characters are allowed. 2.6.5 PASSWORD The Password page allows you to set a three-digit unlock code.
  • Page 67 2.6.6 SERVICE By clicking on the Reset consumption button, the stored values of Volume, Energy and Mass are reset to zero. By clicking on the Reset graphs button, the graphs are reset. 2.7 INFO The info page displays device information: - network status, network parameters (IP address, GATEWAY, DNS1, DNS2);...
  • Page 68: Wireless Connection

    3. WIRELESS CONNECTION With the Wireless version of FLUX 1 and 2, you can establish a connection to a Wi-Fi network via an access point or gateway to monitor and collect all the measured gas values. LINK STRUCTURE WITH THE METAL WORK GATEWAY The Metal Work Gateway handles the collection, formatting and analysis of data, displaying them in a browser-viewable web page.
  • Page 69 WIRELESS CONNECTION FEATURES Gateway SSID_SECURITY nessuna o WPA/WPA2/WPA3 SSID_NAME max. 31 characters SSID_KEY max. 62 characters IP static / DHCP Broker MQTT ENCRYPTION none, TLS 1.0, 1.1, 1.2 (require certificate = false) BROKER IP ADDRESS BROKER IP PORT 1883,8883 User authentication (optional): AUTH_NAME max.
  • Page 70 Example: Dashboard...
  • Page 71: Qualification And Approvals

    4. QUALIFICATION AND APPROVALS This device contains FCC ID: XPYNINAW106 IC: 8595A-NINAW106 The NINA-W15 module series is certified for use in the following countries/regions: • Europe (RED) • USA (FCC) • Canada (IC) • Japan (MIC) • Taiwan (NCC) • South Korea (KCC) •...
  • Page 72 NOTES...

This manual is also suitable for:

Flux 1Flux 2Flux 3Flux 4

Table of Contents