  • Page 1 Heat Pump monobloc SUNSYSTEM MONO PLUS for heating and cooling (with Wi-Fi control) TECHNICAL PASPORT INSTALLATION AND OPERATION MANUAL...
  • Page 2: Table Of Contents

    INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ CONTENT BASIC INSTRUCTIONS AND WARNINGS ................4 HEAT PUMP ENERGY SAVING TIPS ..................5 HEAT PUMP INSTALLATION ....................5 INSTALLATION OF THE HEAT PUMP ..................7 ELECTRICAL CONNECTIONS ....................19 WIRE CONTROLLER ......................
  • Page 3: General Features

    5. A digital controller is incorporated to SUNSYSTEM MONO PLUS is a new generation maintain the desired water temperature. heat pump, specially developed with the new R32 freon with a greener future in mind.
  • Page 4: Basic Instructions And Warnings

    INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 1. BASIC INSTRUCTIONS The power cable has a standard tip, which must be connected to a AND WARNINGS standard outlet (16A; 230V). The  outlet must have a separate power Before starting installation...
  • Page 5: Heat Pump Energy Saving Tips

    INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 2. HEAT PUMP ENERGY SAVING TIPS on the inlet and outlet water connections for If you do not plan to use hot water for a ease of serviceability.
  • Page 6 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 3.2.5. The heat pump must be mounted with shock-resistant bushings to prevent vibration and/or imbalance. 3.2.6. Although the controller is waterproof, care should be taken to avoid direct sunlight and high temperature.
  • Page 7: Installation Of The Heat Pump

    ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 4. INSTALLATION OF THE HEAT PUMP 4.1. Dimensions of the heat pump. SUNSYSTEM MONO PLUS 60 - SUNSYSTEM MONO PLUS 90 SUNSYSTEM MONO PLUS 130 - SUNSYSTEM MONO PLUS 185 - SUNSYSTEM MONO PLUS 230...
  • Page 8 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 4.2. Heat pump components. SUNSYSTEM MONO PLUS 60 № SPARE PARTS № SPARE PARTS 1. Top Cover Water Pump 2. Fixed Frame 18. Right Plate 3. Electrical Box 19. Handle 4.
  • Page 9 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ SUNSYSTEM MONO PLUS 90 - SUNSYSTEM MONO PLUS 130 № SPARE PARTS № SPARE PARTS 1. Top Cover Compressor 2. Fixed Frame 18. Four-way Valve Assembly 3.
  • Page 10 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ SUNSYSTEM MONO PLUS 185 - SUNSYSTEM MONO PLUS 230 № SPARE PARTS № SPARE PARTS 1. Top Cover Right Plate 2. Back Net 18. Water Pump 3. Electrical Box 19.
  • Page 11 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 4.3. Main Parts of the Unit Electrical Box MONO PLUS 60 Electrical Box Cover External Main Board Terminal Block Relay Driver Board Internal Main Board...
  • Page 12 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 4.4. Installation location. 4.5. Minimum distances during installation. 4.5.1. Minimum distances in mm for 1 Choose a place with good air outdoor unit with 1 and 2 fans:  circulation so that the cooled air can flow in and the warm air can flow out.
  • Page 13 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ c) Arrangement in a row: Air inlet Air inlet Air inlet Air inlet Air inlet > 500 > 500 > 500 > 500 > 500 >...
  • Page 14 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ G/ Brackets for floor mounting; G/ Designer cover with console; H/ Strip foundation; H/ Strip foundation; K/ Frost protection for the foundation K/ Frost protection for the foundation (compacted gravel, e.g. 0 to 32/56 mm), layer (compacted gravel, e.g.
  • Page 15 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ Do not close the openings.; G/ Designer cover with console; G/ Brackets for floor mounting; H/ Strip foundation; H/ Strip foundation; K/ Frost protection for the foundation (compacted gravel, e.g.
  • Page 16 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 4.6.2. Wall mounting. b) Wall mount with wall mount а) Wall mounting with a set of wall bracket kit and designer trim. mounting brackets. A/ Gravel layer for percolation of condensate; A/ Gravel layer for percolation of condensate; B/ Vibration isolation;...
  • Page 17 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ charge valve, Three-way valve. Temperature 4.7. Drainage and Condensation sensor should be added in the storage water Condensation will occur from the evaporator tank. An additional electric heater can be when the unit is running and drain at a steady installed in the DHW tank or the buffer tank rate, depending upon ambient air temp.
  • Page 18 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ Sheme 2. Scheme of installation 2 Safety valve Hot water outlet Hot Water Tank EXTERNAL MODULE Cool water inlet Safety valve Fan convectors Hot water outlet 3-way valve Radiators Cool water inlet Floor pipe Water Tank...
  • Page 19: Electrical Connections

    INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 5. ELECTRICAL CONNECTIONS 5.3. Electrical binding of details from the heat pump. Risk of electrical shock or electrocution. Ensure that all high voltage circuits are disconnected before commencing heat 5.3.1.
  • Page 20 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 5.3.3. Binding the elements to the terminal block. № CONNECT TO: № CONNECT TO: N Null Line 13-N External Heat Source 1-2 Thermostat (H Signal) 14-15 External Heat Source 1-3 Thermostat (C Signal) 16-N Anti-freeze Electric Heater Belts...
  • Page 21 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ c) 3# Electromagnetic three-way valve wiring 5.3.5. For Water Pump The 3# electromagnetic three-way valve is used to control whether the water in the balance water tank enters the floor heating waterway in area B.
  • Page 22 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 5.3.6. Electric heater for water tank 5.3.7. For Thermostat "Power input" provides the voltage of "thermostat", and does not directly supply power to the motherboard interface. Port "L1" supplies 220V to the RT connector. Port "L1"...
  • Page 23 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ Method 3. 5.3.7. For Wire Control Switch When "thermostat control" is set to "dual zone switch": When the C signal is closed, the A area is opened;...
  • Page 24: Wire Controller

    INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 6. WIRE CONTROLLER 7. WIRE CONTROLLER - OPERATION GUIDANCE 6.1. The Appearance of The Wired Controller 7.1. Definition of Buttons. ❶ 7.1.1. Single/Double Zone. ❷ In the OFF state, Slide left on the main page - click "General"...
  • Page 25 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 7.1.4. No Hot Water in Double Zone 7.1.6. Lock/Unlock Function a) When the unit is in the off state (both zone At the main interface, press “ ”...
  • Page 26 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 7.1.8. Setting Target Temperature. 7.1.11. Check Parameter Status According to the main page display mode At the main interface, swipe from left to right status setting, click on the target temperature to view the current operating status.
  • Page 27 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 7.2.2. Information Interface At the system parameter interface, press “ ” to enter the information interface. *User parameter Press “User Para” to set the user parameter. *Status Press "Status"...
  • Page 28 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 1) Mute Level :Indicates that the unit is currently in the first level of silence. :Indicates that the unit is currently in secondary silence. 2) Mute Mode :Indicates that the unit is not currently muted.
  • Page 29 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 7.2.7. Timed Function 3) Timed Turn-on Lower Return 1) Timed ON/OFF Setting Pump At the setting interface, click " " and At the setting interface, press " "...
  • Page 30 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 7.2.8. Heating Function Operating conditions: The unit underfloor heating inlet temperature 1) Force Start Water Tank Electric Heater sensor on, otherwise the underfloor heating At the setting interface enter the electric drying function cannot be switched on.
  • Page 31 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 7.2.11. Climate Curve Ambient -10≤TA<15 15≤TA<22 22≤TA<30 30≤TA At the system parameter interface, press Temp. “ ” and input the password “168” to enter the customer management interface. Setting Temp.1 parameters M10-M21.
  • Page 32 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ ≤-20 Ambient Temp. Temp.1 Temp.2 Temp.3 Temp.4 Temp.5 Temp.6 Temp.7 Temp.8 High Temp.1 High Temp.2 High Temp.3 High Temp.4 High Temp.5 High Temp.6 High Temp.7 High Temp.8 Ambient Temp. Temp.1 Temp.2 Temp.3...
  • Page 33 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ Temp.8 High Temp.1 High Temp.2 High Temp.3 High Temp.4 High Temp.5 High Temp.6 High Temp.7 High Temp.8 Ambient ≥20 Temp. Temp.1 Temp.2 Temp.3 Temp.4 Temp.5 Temp.6 Temp.7 Temp.8...
  • Page 34: Appendix

    INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 8. APPENDIX 8.1. Parameters Note: Parameters can only be modified when the unit is powered off, otherwise the parameters cannot be modified successfully. Code Parameter Unit Range Power Mode 0 Standard/1 Powerful/2 Eco/3 Auto Heating &...
  • Page 35 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ A Zone Heating Curve 0 Disable/ 1 Low Temp. Curve 1/ 2 Low Temp. Curve 2/ 3 Low Temp. Curve 3/4 Low Temp. Curve 4/ 5 Low Temp.
  • Page 36 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ Underfloor Heating Preheating 25~35 Temp. Underfloor Heating Preheating 10~40 Interval Underfloor Heating Preheating 48~96 Time Underfloor Heating Water Temp. 0~10 Return Difference Underfloor Heating Room Temp. 0~10 Return Difference Underfloor Heating Before Drying 4~15 Underfloor Heating During Drying...
  • Page 37 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 8.2. Error Code Code Description Causes Solutions 1.The connection between wire 1. Reconnect the wire controller cable. controller and main board is poor. 2. Replace the wire controller. 2.
  • Page 38 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 1.Whether the wiring is loose/ 1.Rewiring/replacement of wires damaged 2. Replace the temperature sensor Hot water tank temperature 2.Temperature sensor fault 3. Replace the main board fault 3.Main board fault 1.Whether the wiring is loose/ 1.Rewiring/replacement of wires damaged...
  • Page 39 INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 1.Whether the wiring is loose/ 1.Rewiring/replacement of wires damaged 0#Suction temperature fault 2. Replace the temperature sensor 2.Temperature sensor fault 3. Replace the main board 3.Main board fault 1.Whether the wiring is loose/ 1.Rewiring/replacement of wires...
  • Page 40 INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 1.Whether the wiring is loose/ 1.Rewiring/replacement of wires damaged 0# Refrigerant gas side 2. Replace the temperature sensor Temp. fault 2.Temperature sensor fault 3. Replace the main board 3.Main board fault 1.Whether the wiring is loose/ 1.Rewiring/replacement of wires damaged...
  • Page 41: Wi-Fi Function

    INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ 9. Wi-Fi FUNCTION 9.5. Modify Device Name / Delete Device Click in the following order to enter device details, and click "Device Name" to rename 9.1.
  • Page 42: Technical Parameters Of The Heating And Cooling Mono Plus

    INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ Model: SUNSYSTEM MONO PLUS MONO PLUS MONO PLUS 60 - 1PH 90 - 1PH 130- 1PH Power supply 230V/1Ph/50-60Hz Refrigerant Type [Space Heating] Ambient Temp. (DB/WB): 7°C/6°C, Water Temp. (Inlet/Outlet): 30°C/35°C.
  • Page 43 Model: SUNSYSTEM MONO PLUS MONO PLUS MONO PLUS MONO PLUS 90 - 3PH 130- 3PH 185 - 3PH 230- 3PH INSTALLATION and OPERATION MANUAL INSTALLATION and OPERATION MANUAL ТЕХНИЧЕСКИ ПАСПОРТ. ИНСТРУКЦИЯ за МОНТАЖ и ЕКСПЛОАТАЦИЯ Power supply 400V/3Ph/50-60Hz Refrigerant Type [Space Heating] Ambient Temp.
  • Page 44 tel.: +359 700 17 343 www.burnit.bg...