Fondital MELORIA 100 Installation & Owner's Manual
Fondital MELORIA 100 Installation & Owner's Manual

Fondital MELORIA 100 Installation & Owner's Manual

Wall hung domestic hot water heat pump heater

Advertisement

Quick Links

HOT WATER HEAT PUMP HEATER
INSTALLATION & OWNER'S MANUAL
EN
Original instructions
Thank you very much for purchasing our product.
Before using your unit , please read this manual carefully and keep it for future reference.
WALL HUNG DOMESTIC
MELORIA 100
MELORIA 150
EN
Translation of the original
instructions (in Italian)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MELORIA 100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Fondital MELORIA 100

  • Page 1 MELORIA 100 MELORIA 150 WALL HUNG DOMESTIC HOT WATER HEAT PUMP HEATER INSTALLATION & OWNER'S MANUAL Translation of the original instructions (in Italian) Original instructions Thank you very much for purchasing our product. Before using your unit , please read this manual carefully and keep it for future reference.
  • Page 2 WARNING This unit is required reliable earthing before usage, otherwise might cause death or injury. If you can't make sure that your house power supply is earthed well, please don't install the unit. Please have a qualified person perform the reliable earthing connection and the installation of the unit. Examples of a qualified person include: licensed plumbers, authorized electric company personnel, and authorized service personnel.
  • Page 3 • Do not leave ammable materials in contact with or in the vicinity of the appliance. • lf the unit has an auxiliary electric heater, it must be installed at least 1 meter (40in) away from any combustible materials. • How to fixed the appliance to its support please refer to detail information of installation. •...
  • Page 4: Table Of Contents

    PRODUCT DATA PLATE ........... . SAFETY INFORMATION .
  • Page 5: Product Data Plate

    1. PRODUCT DATA PLATE Specific and main product data can be found on the label attached to the appliance. SCALDACQUA POMPA DI CALORE HEAT PUMP WATER HEATER Modello Model Alimentazione Power Supply Potenza termica Hea�ng capacity Potenza nominale in ingresso Rated input Potenza nominale ingresso resistenza ele�rica Electric heater rated input...
  • Page 6: Safety Information

    2. SAFETY INFORMATION Please read thoroughly all of the instrucitons before installing or operating the unit. Following safety symbol is very important, always read and obey all safety symbol: CAUTION: You may be injured if you don't obey instructions. WARNING: You may be killed or seriously injured if you don't obey instructions. DANGER: You may be killed or seriously injured immediately if you don't obey instructions.
  • Page 7 • Fill the water heater tank with water and then drain it completely to remove any impurities. Perform this operation at the time of first use or following maintenance work. • It is mandatory to comply with all the installation requirements of the appliance and the system stipulated by the applicable laws, regulations, local and national standards.
  • Page 8: Basic Operation Principle

    3. BASIC OPERATION PRINCIPLE • The water inlet temperature of the equipment shall not be lower than 4°C, and the Maximum water temperature of the equipment can be set as 65°C (by changing the Settings, it can be raised to 70). •...
  • Page 9 CAUTION • The earthing pole of socket must be grounded well, make sure that power supply socket and plug are dry enough and connected tightly. • How to check the power supply socket and plug are qualified? Turn on the power supply and keep the unit running for a half hour, then turn off the power supply and plug out, check whether the socket and plug are hot.
  • Page 10: Before Installation

    4. BEFORE INSTALLATION Unpacking 4.1.1 Accessories Accessory Name Qty. Sharp Purpose Owner’s & Installation Manual Installation and use instruction this manual Prevent tank overpressure, prevent flowing Safety Valve (0.75MPa) backwards Expansion screw Fixed unit 4.1.2 How to transport • In order to avoid scratch or deformation of the unit surface, apply guard boards to the contacting surface.
  • Page 11 • Inside a car or cabin. • The place with direct sunlight and other heat supplies. If there’s no way to avoid these, please install a covering. • Place like kitchen where oil permeates. • Place where strong electromagnetic waves exist. •...
  • Page 12: Installation

    5. INSTALLATION WARNING • The installation of the equipment must be carried out by qualified personnel; the installation must be carried out in accordance with national regulations and to all additional requirements of local authorities. • Do not use means to accelerate the defrosting process or for cleaning other than those recommended by the manufacturer.(IEC 60335-2-40 ANNEX DD.2) •...
  • Page 13: Mounting Dimension

    Mounting dimension installation holes Fig. 1 Mounting dimension Model MELORIA 100 1328 MELORIA 150 1675 • Place the water heater in a room protected from frost. • Place it as close as possible to important points of use. • Make sure that the support element is sufficient to receive the weight of the water heater full of water.
  • Page 14 It is mandatory to install the water heater on a support . Place the water heater If the wall is not load-bearing : on the bracket to mark the fixing points. Make the holes and then reinstall the water heater in its place. The anti-tilting fixing by the upper bracket is obligatory (fixing Ø...
  • Page 15: Air Duct Connection

    • The drainage pipe should be well insulated in order to prevent water inside pipe from freezing in cold weather. Unit outline dimension (unit: mm) Model Dimension MELORIA 100 500 (L) × 1360 (H) MELORIA 150 500 (L) × 1708 (H) NOTE: Use tools to disassemble the filter for cleaning.
  • Page 16: Typical Installation

    NOTE • The pressure drop in the duct will decrease the air flow rate, which will reduce the capacity of the unit. • Condensation may form on the outer surface of the ducts, harder in the exhaust air one. Be aware of this condition. We strongly recommend using thermally insulated ducts or thermally insulating the installed ducts.
  • Page 17 NOTE • The resistance of duct will decrease air-flow-rate, which will lead to capacity of unit decreased. • For the case of unit with duct, the duct total length should be no more than 5m , and the quantity of bending should be no more than 3.
  • Page 18: Electrical Connection

    • After wire connection, check it again and make sure the correctness before power on. • Products for indoor use only. 5.4.1 Specifications of Power Supply Model Name MELORIA 100 MELORIA 150 Power Supply 220-240V~50Hz Min. Diameter of Power Supply Cord (mm ≥1.5...
  • Page 19: Cold Water Connection

    Cold water connection Before connection check that the piping is clean without any particles from installation. The installation has to include a new safety valve set to 7 bar ( 0,75 MPa ), compliant to EN 1487 and connected directly on the cold water inlet.
  • Page 20: Installation Checklist

    Depending on the degree of humidity in the air you can get up to 0,25l/h of condensation. The evacuation of condensate should not been made directly to sew water because of possible corrosive gasses damaging the exchanger fins and water heater parts. WARNING Do not block off the safety valve drainage pipe.
  • Page 21: Electrical Connections

    5.8.2 Water System Piping Check Description All piping properly installed and free of leaks. □ Unit completely filled with water. □ Water temperature limit valve or mixer tap(recommanded) installed per manufacturer’s instructions. □ 5.8.3 Condensate Drain Line Installation Check Description Must be located with access to an adequate drain or condensate pump.
  • Page 22: Trial-Running

    6. TRIAL-RUNNING Water affusion before operation Before using this unit, please follow the steps below. Water Affusion: If the unit is used for the first time or used again after emptying the tank, please make sure that the tank is full of water before turning on the power.
  • Page 23: About Running

    6.2.2 About running 1. System Structure Figure. Unit has two kinds of heat sources: heat pump(compressor) and electric heater. Unit will automatically select heat sources to heat water to the target temperature. Temperature sensor(T5U) Temperature sensor(T5L) Water outlet Water inlet 2.
  • Page 24: Vacation Function

    Time (h) Ambient temperature (°C) • Defrosting During Water-heating: in heat pump running period, if the evaporator frosted in lower ambient temperature, the system will defrost automatically to keep effective performance(about 3~10min). At defrosting time(when the ambient temperature is below 5°C), the fan motor will stop, but compressor will still run.
  • Page 25 parameters unit Explenation Temp. Temp. Temp. Temp. Heat pump stop water temp Temp. Temp. Temp. Temp. Temp. Disinfect temp. Current Compressor and electric heating current Ac Fan 0: OFF 1: LOW 2: MID 3: HIGH Dc Fan Real speed/10 Machine parameters 0~255 Electronic expansion valve opening Compression mechanism hot water demand...
  • Page 26: Operation

    7. OPERATION Control panel explanation Display Operation 7.1.1 Display explanation OPERATION...
  • Page 27 Number Description will be lightened if screen is unlocked. It shows water temperature on normal. It shows remaining vacation days on vacation. It shows setting temperature on setting. It shows unit setting/running parameters, error/protection code on querying. Time and clock setting shows the clock.
  • Page 28 Number Description When any key is invalid, this icon will flash 3 sec. The icon lights up when the water temperature is being set. The icon lights up when the clock is being set. Wireless: will be lightened when Wireless is connected; will be extinguished when Wireless is not connected;...
  • Page 29 Icon Description Checking function 1) In the main interface, press and hold the search key for 1 second to enter the spot check function, and use the up and down keys to switch the spot check channel, and the attribute value of the channel will be displayed when switch- ing to the channel, and the specific channel can be found in the function book.
  • Page 30: Combination Button

    Combination button Icon Description 1) In the main interface, press and hold the timer button for 3 seconds to enter the date setting, press the up/down button to select the date, press the confirmation button to enter the clock setting, press the up/down button to modify the time, and press and hold to accelerate the increase/decrease of the time.
  • Page 31 To turn on /off the electrical heater. NOTE • In order to avoid to affect the effectiveness of the hot water heating process, we recommend users not to turn off the electrical heater. Long press for 3 seconds to enter engineering Press the up and down keys to operate mode and select F6 channel.
  • Page 32: Use Your Appliance With The Nethome Plus App

    Use Your Appliance with the NetHome Plus App NOTE • Ensure that your mobile phone is connected to the home wireless network, the 2.4GHz band wireless signal is enabled on your wireless router and you know the network password. • Turn on Bluetooth on your phone and the device must also be powered up. Step 1: Download NetHome Plus App.
  • Page 33 Step 4: Choose Air Source Heat Pump Water Heater. Step 5: Connected to the network. Follow the instructions in the app to set up the Wireless connection. If the network connection fails,please refer to the App tips for operation. OPERATION...
  • Page 34: Auto-Restart

    7.3.1 Compliance We, hereby declare that this device is in compliance with the relevant provisions of RE Directive 2014/53/EU. Wireless module models: EU-SK110, US-SK110: FCC ID: 2ADQOMDNA23 IC: 12575A-MDNA23 BLE:2402-2480MHz, TX Power:<10dBm Wi-Fi:2400-2483.5MHz, TX Power:<20dBm This device complies with Part 15 of the FCC Rules and it contains licence exempt transmitter(s) / receiver(s) that comply with Inno- vation, Science and Economic Development Canada’s licence-exempt RSS(s).Operation is subject to the following two conditions: (1)This device may not cause harmful interference;...
  • Page 35: Wiring Diagrams

    Wiring diagrams Fig. 2 Wiring diagram OPERATION...
  • Page 36 Code Description Current transformer Zero sequence current transformer Evaporator temperature sensor Ambient temperature sensor Tank temperature sensor (upper) Tank temperature sensor (lower) Discharge temperature sensor Suction temperature sensor Electronic expansion valve Mid terminal base Tank temperature sensor (middle) E-Mg Electronic magnesium rod SMART GRID Operating behavior EVU/PV...
  • Page 37: Trouble Shooting

    8. TROUBLE SHOOTING Non-error tips Q: Why can’t compressor start immediately after setting? A: The unit will wait for 3 minutes to balance the pressure of system before starting compressor again. It's a self protection logic of unit. Q: Why dose the temperature shown on the display panel decreased sometimes while unit is running? A: When the upper tank temperature is much higher than the bottom part, upper part hot water will be mixed by the bottom cold water which is continually flow from inlet pipe so that will decrease the upper part temperature.
  • Page 38: Error Code Shooting Table

    Error phenomenon Possible reason Solution Check and reseal all joints. Hydraulic pipeline joints are not sealed Water leakage well. A pipe or fitting is broken. Check piping. Error code shooting table Display Malfunction Description Corrective Action Maybe the connection between LCD panel and PCB has EH0b Tank and LCD panel communication error.
  • Page 39: Maintenance

    Display Malfunction Description Corrective Action Maybe because of system blocked, air or water or High TP protection. Tp > 110°C (185L). Tp > 105°C less refrigerant(leakage) in system( after repair), water PC06 (275L). Protection active; Tp < 90°C Protection inactive. temperature sensor malfunction, etc.
  • Page 40 • Sealed electrical components shall not be repaired.(IEC 60335-2-40 ANNEX DD.4.10) • Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environ- mental effects. The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.(IEC 60335-2-40 ANNEX DD.7) •...
  • Page 41: Maintenance

    • Label the system when charging is complete (if not already labelled).(IEC 60335-2-40 ANNEX DD.10) • Extreme care should be taken not to overfill the refrigeration system.(IEC 60335-2-40 ANNEX DD.10) • Prior to recharging the system, it shall be pressure-tested with the appropriate purging gas. The system shall be leak-tested on completion of charging but prior to commissioning.
  • Page 42: Recommended Regular Maintenance Table

    • Checking of protective anodes.For more details, please contact the supplier or the after-sale service. E-heater Anode Rod Nuts Undercoat Screws » Empty the product. » Loosen the screws on the undercoat. » Remove the undercoat. » Remove the cable from the electrical immersion resistance. »...
  • Page 43: Specifications

    SPECIFICATIONS Model MELORIA 100 MELORIA 150 Water-heating cap.(a) 980W 1300W Rated power/AMPS 1950W/9A 2250W/10.5A Power supply 220-240V~ 50Hz Operation control Auto/Manual startup, error alarm, timer Over-load Protector, Temp Controller&Protector, Electric Leak- Protection age Protector E-heater power 1500W Refrigerant R290/0.15kg Outlet water temp.(b) Default 50°C,(38-65°C adjustable)
  • Page 44: Disposal And Recycling

    DISPOSAL AND RECYCLING WARNING • Decommissioning and disposal operations must be carried out by qualified personnel in accordance with local and national regu- lations. • Good practice for safely recovering all refrigerants is recommended. • Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recov- ered refrigerant.
  • Page 45 Important instructions for environment(European Disposal Guidelines) Compliance with the WEEE Directive and Disposing of the Waster Product: This product complies with EU WEEE Directive (2012/19/EU). This product bears a classification symbol for waster electrical and electronic equipment (WEEE). This symbol indicates that this product shall not be disposed with other household wastes at the end of its service life.
  • Page 46 Page left intentionally blank...
  • Page 47 Page left intentionally blank...
  • Page 48 Fax +39 0365 878 304 e-mail: info@fondital.it www.fondital.com The manufacturer reserves the right to modify his/her products as deemed necessary, without altering the basic characteristics of the products themselves. Uff. Pubblicità Fondital IST 03 J 113 - 02 | Marzo 2025 (03/2025)

This manual is also suitable for:

Meloria 150

Table of Contents