Daikin Perfera ZETA R32 Service Manual page 74

Table of Contents

Advertisement

4
|
Components
To install the compressor
Service manual
74
INFORMATION
If the pipes that were removed together with the compressor are NOT included in
the spare part compressor, install and solder the reused or new pipes to the spare
part compressor before installing the compressor.
1 Check the state of the dampers. Replace if worn.
2 Install the 3 dampers and springs (if applicable) in the correct location on the
unit.
3 Remove the plugs or caps from the refrigerant piping and make sure they are
clean.
4 Remove the caps from the compressor pipes (of the new compressor).
CAUTION
The oil in the compressor is hygroscopic. Therefore remove the caps from the
compressor pipes as late as possible.
5 Install the compressor on the correct location on the dampers. Properly insert
the refrigerant pipes in the pipe expansions of the compressor pipes.
6 Install and tighten the bolts and nuts to fix the compressor to the dampers.
A
a
c
c
A Class 20~35 unit
a Nut
b Compressor
c Damper
A
a
c
A Class 42~60 units + ARXM71A
b
b
RXM20~71A + RXM25~50A9 + ARXM25~71A + ARXM35+50A9 +
c
a
c
FTXM20~71A + ATXM20~50A + CTXM15A
Split Perfera ZETA R32