Empire DV20E-6 Installation Instructions And Owner's Manual

Fan type direct-vent wall furnace

Advertisement

Available languages

Available languages

Quick Links

INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING
FIRE OR EXPLOSION HAZARD
If the information in these instructions is
not followed exactly, a fire or explosion
may result causing property damage,
personal injury or loss of life.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
This appliance may be installed as an OEM
installation in a manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280, in the United States, or the
Mobile Home Standard, CAN/CSA Z240 MH
Series, in Canada.
This appliance is only for use with the
type(s) of gas indicated on the rating plate. A
conversion kit is supplied with the appliance.
NOTICE: Contact your dealer for installation, service, repair, or warranty claim
Empire Comfort Systems does not sell, service, or provide warranty directly to consumers. The consumer must contact the dealer where the
product was purchased for a warranty claim. If a non-qualified installer or consumer installs or services this product, the product warranty is
voided. Most dealers will only service products they sold so it is important for the consumer to choose a qualified dealer for installation and
warranty service. In order to maintain the warranty, service must be performed annually and documentation reviewed during the warranty request.
INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
FAN TYPE DIRECT - VENT
WALL FURNACE
FOR INSTALLATION IN
MANUFACTURED ( MOBILE HOME ) ,
MODULAR OR RESIDENTIAL HOMES
MODELS:
DV20E - 6 | DV40E - 6
WARNING
If not installed, operated and maintained in
accordance with the manufacturer's instructions,
this product could expose you to substances in
fuel or from fuel combustion which can cause
death or serious illness.
Patent # 5.664.555

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DV20E-6 and is the answer not in the manual?

Questions and answers

Summary of Contents for Empire DV20E-6

  • Page 1 NOTICE: Contact your dealer for installation, service, repair, or warranty claim Empire Comfort Systems does not sell, service, or provide warranty directly to consumers. The consumer must contact the dealer where the product was purchased for a warranty claim. If a non-qualified installer or consumer installs or services this product, the product warranty is voided.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS SECTION PAGE Important Safety Information ............................. 3 Safety Information for Users of Propane Gas ......................4 Requirements for Massachusetts ..........................5 Introduction ................................6-7 Specifications ................................7 Gas Supply ................................8 Gas Conversion Instructions ............................. 9 Clearances ................................10 Furnace Installation ............................
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION THIS IS A HEATING APPLIANCE DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED. • Due to high temperatures the appliance should be located • Installation and repair should be done by a QUALIFIED out of traffic and away from furniture and draperies. SERVICE PERSON.
  • Page 4: Safety Information For Users Of Propane Gas

    SAFETY INFORMATION FOR USERS OF PROPANE GAS Propane is a flammable gas which can cause fires and Someday when there may not be a minute to lose, everyone's explosions. In its natural state, propane is odorless and safety will depend on knowing exactly what to do. If, after colorless.
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS 4. INSPECTION. The state or local gas inspector of the For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole side wall horizontally vented gas fueled equipment shall or in part for residential purposes, including those owned or not approve the installation unless, upon inspection, operated by the Commonwealth and where the side wall...
  • Page 6: Introduction

    INTRODUCTION Introduction Qualified Installing Agency Always consult your local Building Department regarding regulations, Installation and replacement of gas piping, gas utilization equipment codes or ordinances which apply to the installation of a direct vent or accessories and repair and servicing of equipment shall be wall furnace.
  • Page 7: Specifications

    INTRODUCTION (CONT'D) When an existing Category 1 heater is removed or replaced, the improperly sized venting system (formation of condensate, leakage, original venting system may no longer be sized to properly vent the spillage, etc.) and shall specify the following test procedure: attached appliances.
  • Page 8: Gas Supply

    GAS SUPPLY Consult the current National Fuel Gas Code, ANSI Z223.1 Installing a New Main Gas Shut-Off CAN/CGA-B149 (.1 or .2) installation code. Each appliance should have its own manual gas shut-off. A manual main gas shut-off should be located in the vicinity of the RECOMMENDED GAS PIPE DIAMETER unit.
  • Page 9: Gas Conversion Instructions

    GAS CONVERSION INSTRUCTIONS WARNING Conversion must be done by a qualified service technician. Main burner orifice(s) and new gas conversion label are provided in conversion kit attached to manifold pipe. CONVERSION INSTRUCTIONS FROM PROPANE GAS TO NATURAL GAS Make sure gas supply to furnace is off prior to conversion and GAS VALVE SWITCH disconnect electrical power to unit.
  • Page 10: Clearances

    CLEARANCES 1. Pick a location on a wall with a clear space of 36" (91.4cm) The vent terminal of a direct vent appliance, with an input of 50,000 high by 43" (109cm) wide in the room. In selecting a location BTU (14.6KW) per hour or less shall be located at least 9"...
  • Page 11 FURNACE INSTALLATION (CONT'D) Installing Wall Bracket (See Figures 5 and 6) After finding a location for the furnace, gas supply and vent, the wall bracket must be positioned and installed. The bracket should be mounted to the wall studs, if possible, or anchored solidly to the EXHAUST AIR EXHAUST AIR ORANGE SILICONE...
  • Page 12 FURNACE INSTALLATION (CONT'D) Be sure to deburr the ends with a file after cutting. Installation is It is also necessary to adequately support both the exhaust and easy after cutting the wall opening secure the vent terminal box intake and to center the exhaust pipe in the wall. in place using the (4) 10 x 1"...
  • Page 13 FURNACE INSTALLATION (CONT'D) If local codes prohibit condensate from draining to the outside and VENT TERMINAL VENT TERMINAL the appliance produces condensate you must purchase condensate drain kit, part number DV-1108. INTAKE INTAKE EXHAUST EXHAUST SLOPE THE VENT TERMINAL SLOPE THE VENT TERMINAL HORIZONTAL RUN DOWNWARD HORIZONTAL RUN DOWNWARD THE OUTSIDE TO DRAIN OUT...
  • Page 14: Lighting Instructions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped •...
  • Page 15: Wiring

    WIRING GV = GAS VALVE LS = LIMIT SWITCH FS = FLAME SENSOR XFMR = TRANSFORMER PS = PRESSURE SWITCH IGN = HOT SURFACE IGNITOR ROS = ROLLOUT LIMIT SWITCH OPTIONAL WALL MOUNT THERMOSTAT DISCONNECT INTEGRAL THERMOSTAT "R", "W", AND "C" LEADS AND ATTACH WALL THERMOSTAT AS SHOWN CORDSET 115 VAC XFMR BLACK HOT...
  • Page 16: Maintenance

    MAINTENANCE Proper Main Burner Flame Removing Gas Valve The proper main burner flame will be a blue primary (inner) 1. Remove front grill assembly. flame with a larger, lighter blue secondary (outer) blue flame. 2. Disconnect manifold union assembly at gas valve. 3.
  • Page 17: Furnace Control Board Diagnostics

    Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Shipments contingent upon strikes, fires and all causes beyond our control. Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, IL 62222-0529 45354-0-1023 Page 17...
  • Page 18: Parts List

    PARTS LIST PLEASE NOTE: When ordering parts, it is very important that part number and description of part coincide. INDEX PART INDEX PART DESCRIPTION DESCRIPTION DV1378 SHROUD TOP DV1038 BURNER COMPARTMENT ACCESS PANEL DV1376 SHROUD SIDE RIGHT DV1039 BURNER COMPARTMENT R2521 AIR FILTER R13543...
  • Page 19: Parts View

    PARTS VIEW 11 11 11 11 45354-0-1023 Page 19...
  • Page 20: Appliance Service History

    APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes Page 20 45354-0-1023...
  • Page 21 APPLIANCE SERVICE HISTORY Date Dealer Name Service Technician Name Service Performed/Notes 45354-0-1023 Page 21...
  • Page 22: Master Parts Distributor List

    MASTER PARTS DISTRIBUTOR LIST To Order Parts Under Warranty, please contact your local Empire dealer. See the dealer locator at www.empirecomfort.com. To provide warranty service, your dealer will need your name and address, purchase date and serial number, and the nature of the problem with the unit.
  • Page 23: Warranty

    WARRANTY Empire Comfort Systems Inc. warranties this space heating product to be free from defects at the time of purchase and for the periods specified below. Space heating products must be installed by a qualified technician and must be maintained and operated safely, in accordance with the instructions in the owner’s manual.
  • Page 24 Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 24 45354-0-1023...
  • Page 25 REMARQUER : Contactez votre revendeur pour l’installation, l’entretien, la réparation ou la réclamation au titre de la garantie. Empire Comfort Systems ne vend, n’entretient pas et ne fournit pas de garantie directement aux consommateurs. Le consommateur doit communiquer avec le détaillant où le produit a été...
  • Page 26 LA TABLE DES MATIÈRES SECTION PAGE Information Importante de Sécurité ......................3 Information de Sécurité pour les Utilisateurs de Propane ................4 Introduction .............................5-6 Spécifications ............................. 6 Alimentation en Gaz ........................... 8 Les Instructions Pour La Conversion des Gaz ................... 9 Espaces Libres ............................
  • Page 27: Information Importante De Sécurité

    INFORMATION IMPORTANTE DE SÉCURITÉ CECI EST UN APPAREIL DE CHAUFFAGE NE PAS FAIRE FONCTIONNER CET APPAREIL SANS QUE LE PANNEAU DU DEVANT SOIT INSTALLÉ. • A cause des hautes températures, cet appareil doit être situé • L'installation et la réparation doivent être faites par une dans un endroit non achalandé...
  • Page 28: Information De Sécurité Pour Les Utilisateurs De Propane

    INFORMATION DE SÉCURITÉ POUR LES UTILISATEURS DE PROPANE Le propane est un gaz inflammable qui peut causer des incendies et Un jour, quand il n’y aura peut-être pas une minute à perdre, la sécurité de tout le monde dépendra de savoir exactement quoi faire. des explosions.
  • Page 29: Introduction

    INTRODUCTION AGENCE D'INSTALLATION QUALIFIÉE NTRODUCTION Toujours consulter le département de construction de votre région en ce L'installation et le remplacement des tuyaux à gaz, des équipements ou qui regarde les règlements, les codes ou les ordonnances qui s'appliquent accessoires, la réparation et l'entretien de l'équipement doivent être faits seulement par une agence qualifiée.
  • Page 30: Spécifications

    INTRODUCTION (SUITE) Lorsqu'un radiateur de catégorie 1 existant est retiré ou remplacé, le également indiquer les effets d'un système de ventilation de taille système de ventilation d'origine peut ne plus être dimensionné pour inadéquate (formation de condensat, fuite, déversement, etc.) et doivent ventiler correctement les appareils raccordés.
  • Page 31 Cette page a été intentionnellement laissée vierge. 45354-0-1023 Page 7...
  • Page 32: Alimentation En Gaz

    ALIMENTATION EN GAZ Emplacement de l’Alimentation de Gaz Installation d’un Nouveau Robinet Principal pour le Gaz La ligne de gaz peut entrer dans l'appareil soit en venant du plancher ou du Chaque appareil doit avoir son propre robinet manuel de gaz. Dans l'État mur extérieur.
  • Page 33 INSTRUCTIONS DE CONVERSION DE GAZ AVERTISSEMENT Conversion doit être faite par un technicien d’entretien qualifié. Les orifices du brûleur principal et la nouvelle étiquette pour le changement des gaz sont fournis dans l’ensemble de conversion qui est attaché au tuyau de gaz. LES INSTRUCTIONS POUR LA CONVERSION DU GAZ PROPANE AU GAZ NATUREL Assurez-vous que l’alimentation en gaz de la fournaise est éteinte avant INTERRUPTEUR DE SOUPAPE DE GAZ...
  • Page 34: Espaces Libres

    ESPACES LIBRES Choisissez un endroit sur un mur qui aura un espace libre de 36” AVERTISSEMENT (91.4cm) de haut par 43” (109cm) de large. En choisissant un em- placement, il est nécessaire de fournir l'espace libre adéquat pour Le point le plus près du capuchon de l'évent doit être éloigné l'accès à...
  • Page 35 Installation du Support Mural (Figures 5 and 6) Après avoir trouver l'emplacement du radiateur, l'alimentation de gaz et l'évent, le support mural doit être placé et installé. Le support doit être attaché aux montants du mur, si possible, ou accroché solidement au mur. CONNECTEUR COUDÉ...
  • Page 36: Installation Du Four

    INSTALLATION DU FOUR Soyez certain d'ébarber l'extrémité coupée avec une lime. ABS-DWV et F628 pour SCH.40 ABS. Le ciment pour tuyau et L'installation sera facile àprès avoir coupé l'ouverture murale. la couche d'apprêt doivent être utilisés conformément avec ASTM Fixer en place la boîte de l'évent terminal en utilisant les (4) vis à Standard D2564 pour PVC ou D2235 pour ABS.
  • Page 37 PLAT DE SUPPORT BORNE DE PASSAGE COURSE HORIZONTALE DE PENTE BORNE DE PASSAGE DE HAUT EN BAS VERS L'EXTÉRIEUR AU DRAIN HORS DU CONDENSAT COLLIERS DE LA CONDUITE PRISE ÉCHAPPEMENT MUR EXTÉRIEUR ACCOUPLEMENT EN CAOUTCHOUC AVEC DES COLLIERS DE LA CONDUITE SUPPORT DE SUPPORT DE MUR DE PIPE DE PASSAGE POUR DES COURSES VERTICALES DE 6FT.
  • Page 38: Instructions D'allumage

    INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LIRE AVANT D'ALLUMER AVERTISSEMENT Si vous ne suivez pas exactement ces instructions, un feu ou une explosion peut se produire causant des dommages à la propriété, des blessures corporelles ou la mort. A. Cet appareil n'a pas de veilleuse. Il est muni d'un dispositif C.
  • Page 39: D'installation Électrique

    D’INSTALLATION ÉLECTRIQUE SCHÉMA DE CÂBLAGE AVERTISSEMENT: DÉBRANCHER L'ALIMENTATION ÉLECTRIQUE AVANT TOUTE INTERVENTION GV = ROBINET DE GAZ LS = CONTACT FIN DE COURSE FS = CAPTEUR DE FLAMME XFMR = TRANSFORMATEUR THERMOSTAT MURAL EN OPTION PS = MANOCONTACT IGN = ALLUMEUR SURFACE CHAUDE DÉBRANCHER LES FILS “R”, “W”...
  • Page 40: Maintenance

    MAINTENANCE Aspect Convenable de la Flamme du Brûleur Principal Enlever la Valve de Gaz 1. Enlever l'assemblage du grillage avant. La flamme convenable pour le brûleur principal consistera 2. De la valve de gaz, débrancher le raccord du tuyau de gaz. d'une flamme (intérieure) primaire bleue avec une flamme 3.
  • Page 41 DIAGNOSTIC DU CIRCUIT DE COMMANDE DE CHAUDIÈRE CODE D’ERREUR SÉQUENTIEL — GUIDE DE DÉPANNAGE Clignotements État d’erreur Correction de l’erreur Allumé Commande OK en continu 1 clignotement Le rupteur thermique est ouvert -Vérifier l’absence d’obstruction de l’admission ou la grille de refoulement de soufflante d’air de chauffage, conduite de soufflante d’induction/air de chauffage vers échangeur et rupteur -Voir s’il y a un retour de flamme causant l’ouverture du limiteur de...
  • Page 42: Façon De Commander Les Pièces De Réparations

    Ne pas commander les boulons, les vis, les rondelles ou les écrous. Ce sont des pièces standard que vous pouvez acheter dans les quincailleries. L'expédition des marchandises se fera sans délai, excepté en cas de grèves, de feux ou toutes autres circonstances indépendantes de notre volonté. Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, IL 62222-0529 LISTE DES PIÈCES S'IL VOUS PLAÎT NOTER: LORSQUE VOUS COMMANDEZ LES PIÈCES, IL EST TRÈS IMPORTANT QUE LE NUMÉRO DE LA PIÈCE ET LA DESCRIPTION COÏNCIDENT.
  • Page 43: Vue Des Pièces

    VUE DES PIÈCES 11 11 11 11 45354-0-1023 Page 19...
  • Page 44: Garantie

    Garantie Limitée De Dix Ans Sur Les Pièces - Chambre De Combustion Empire promet au propriétaire que si la chambre de combustion (voir la liste des pièces) tombe en panne à cause d’un navire ou d’un matériel de fabrication défectueux et qu’il a dix ans à compter de la date d’achat, Empire réparera ou remplacera à sa convenance.

This manual is also suitable for:

Dv40e-6

Table of Contents