Maytag MGC6430BDB - 30" Gas Cooktop Installation Manual

Maytag MGC6430BDB - 30" Gas Cooktop Installation Manual

Sealed gas cooktop
Hide thumbs Also See for MGC6430BDB - 30" Gas Cooktop:

Advertisement

SEALEDGAS COOKTOPS
Models: MGC6430 & MGC6536
IMPORTANT:
Dimensions
Shown in Both Inches and Centimeters.
IMPORTANT:
Be sure the appliance being installed is equipped for the gas to be supplied. Refer to serial plate on
underside of burner box for this information. Do not attempt to convert this appliance for use with a gas other than the type
specified.
DIMENSIONS
inches
cm
A
28 1/2
+ 1/16
72.4
+ 0.2
B
19 15/16 + 1/16
50.6
+ 0.2
C
21/8
+ 1/16
5.4
+ 0.2
D
51/4
+ 1/16
13.3
+ 0.2
E
30
+ 1/16
76.2
+ 0.2
F
21 1/2
+ 1/16
54.6
+ 0.2
G
313/16
+ 1/16
9.7
+ 0.2
H
12 1/4
+ 1/16
31.1
+ 0.2
DIMENSIONS
inches
cm
A
34 1/2
+ 1/16
87.6
+ 0.2
B
19 15/16 + 1/16
50.6
+ 0.2
C
21/8
+ 1/16
5.4
+ 0.2
D
51/4
+ 1/16
13.3
+ 0.2
E
36
+ 1/16
91.4
+ 0.2
F
21
+ 1/16
53.3
+ 0.2
G
313/16
+ 1/16
9.7
+ 0.2
H
151/4
+ 1/16
38.7
+ 0.2
CUTOUT
DIMENSIONS
ARE CRITICAL
SPECIAL WARNING:
IMPROPER
INSTALLATION,
ADJUSTMENT,
ALTERATION,
SERVICE,
MAINTENANCE
OR USE OF RANGE
CAN RESULT
IN SERIOUS
INJURY
OR PROPERTY
DAMAGE.
NOTICE
TO INSTALLER:
Leave
these
instructions
with the appliance.
NOTICE
TO CONSUMER:
Retain these
instructions
for future
reference.
8101 P524-60
(01-03-00)

Advertisement

Table of Contents
loading

Summary of Contents for Maytag MGC6430BDB - 30" Gas Cooktop

  • Page 1 SEALEDGAS COOKTOPS Models: MGC6430 & MGC6536 IMPORTANT: Dimensions Shown in Both Inches and Centimeters. IMPORTANT: Be sure the appliance being installed is equipped for the gas to be supplied. Refer to serial plate on underside of burner box for this information. Do not attempt to convert this appliance for use with a gas other than the type specified.
  • Page 2: Important Preparation Suggestions

    Location Of Your Maytag Important Preparation Appliance Suggestions Locate this appliance away from combustible materials 1. Chamfer all exposed edges of decorative laminate to such as window curtains and combustible wall prevent damage from chipping. decorations. 2. Radius corners of cutout and file to insure smooth edges and prevent corner cracking.
  • Page 3: Mobile Homes

    No. 70-Latest Edition, or, in Canada, current 1, page 4. CSA Standard C22.1 Canadian Electrical Code, Part 1. • If this unit is to be installed over a Maytag Model In The Commonwealth Of Massachusetts MEW6500 or MEW5500 Series Electric Wall Oven This product must be installed by a licensed plumber or proceed as instructed under paragraph 2, page 5.
  • Page 4: Burner Box

    Connecting Appliance To Gas Supply Apply a non-corrosive leak detection fluid to all joints and A QUALIFIED SERVICE TECHNICIAN OR GAS fittings in the gas connection between the supply line APPLIANCE INSTALLER MUST MAKE THE GAS shut-off valve and the cooktop. Include gas fittings and joints in the cooktop if connections were disturbed...
  • Page 5 2. IF THIS UNIT WILL HAVE A MAYTAG MODEL ILLUSTRATIVE GAS SUPPLY PIPING MEW6500 or MEW5500 SERIES ELECTRIC WALL (WALL OVEN INSTALLED BELOW 30" COOKTOP) OVEN INSTALLED BELOW THIS COOKTOP. NOTE 1 : This appliance and its gas and electrical supply •...
  • Page 6: Pressure Testing

    Pressure Testing Alternative Piping Methods To The appliance must be isolated from the gas supply Connect Appliance To Gas Supply piping system by closing its individual manual shut-off A TRAINED SERVICE TECHNICIAN OR GAS valve during any pressure testing of the gas supply piping APPLIANCE INSTALLER MUST MAKE THE GAS...
  • Page 7: Electrical Wiring Information

    Electrical Wiring Information can be located as is convenient in this left wall or in the This appliance is equipped with a grounded type power cord. A grounded outlet must be provided. It is corresponding right wall. recommended, for convenience, the outlet be located In planning any installation, note that the free length of (with reference to figure 6) as in A or B, below: this appliance's power cord, extending beyond a point...
  • Page 8: Converting Appliance For Use With Lp Gas

    Converting Appliance For Use Installation Of LP Orifice Spud With LP Gas 0' 91CZJ_ 1 WARNING Propane conversion is to be performed by a MAYTAG AUTHORIZED SERVICER (or other qualified agency) in accordance with the manufacturer's instructions and all © codes...
  • Page 9: Flame Appearance

    B. INVERT CAP IN APPLIANCE PRESSURE REGULATOR (See figure 11) With the appliance installed, the appliance regulator After adjusting the screw the burner should produce a should be located as shown in figure 3, 4 or 5. stable, steady blue flame of minimum size. The setting should be checked by turning knob from high to low CONVERSION OF APPLIANCE...
  • Page 10 To Convert Appliance For Use 4 BURNER MODEL (30" WIDE) With Natural Gas Electrical power and gas must be turned WARNING prior to conversion. If this appliance has been converted for use with LP gas, each of the following modifications must be performed to convert the unit back to natural gas.
  • Page 11: Burner Performance

    4 BURNER MODEL (30" Wide) f/ II '% 9215"2e7"_ ARTB ARTff 9215-213-0 FIGURE15 FIGURE17 MAYTAG36" MAYTAG 30" INPUT RATES - NATURALGAS / LP GAS (BTU/HR) INPUT RATES- NATURALGAS / LP GAS (BTU/HR) BURNERLOCATION BURNERLOCATION Right Front 12,500 / 10,500 1300/ 1300 Right Front...

This manual is also suitable for:

Mgc6430Mgc6536

Table of Contents