Page 1
HRS-255 Continuous Band Sealer Instruction Manual Distributed By: Version 2.5...
Page 2
Preface Thank you for buying the Continuous Band Sealer of HRS-225. This instruction manual has following content: Instruction on the product Precaution on safety Transportation and storage Installation and commissioning Instruction for use Troubleshooting Spare parts ...
Page 3
1.Instructions on products 1.1 Application fields HRS-255 series continuous paper/plastic sealers are designed to heat seal paper/ plastic bags, paper/plastic cubic bags and paper/ paper bags etc. It adopts continuous sealing type without restriction of bag width. 1.2 Heat-sealable materials Bags and bag rolls that comply with guidelines of EN868-5 and YY/T0698-5 ...
Page 4
1.5 Parameters of products Speed:10m/min Distance from sealing center to bag top:0~60mm Adjustable Seal width:12mm Operation temperature:60~220℃Adjustable Temperature Accuracy:≤1% Working environment:5~30℃ Voltage:AC 220V 50HZ or AC110V 60HZ Motor power:25W Heater Power:200W Fuse:5AX2 ...
2.Safety 1. Preparation: This instruction is a detailed description of the Carrying, Storage, Installation, Startup, Operating condition, Maintenance, troubles & solutions and Repairing. The installation of machine is suggested to be operated by trained person. Pls follow the the maintenance instructions Before operating the machine, pls be sure to read the operation manual carefully ...
Page 6
3. Equipment movements and storage 1. With Carton Packing If the machine is packed by carton with expanded gasket, Remove the expanded gasket from the carton. If the machine is packed by carton with foam material, Remove the foam material from the carton. ...
4. Installation Before installation and operation, please read this manual carefully. You can get the information of the installation, starting, maintenance and operation of the machine. Supplier is not responsible for the problem caused by the operation against this manual. Supplier wants all client use this machine without any problem.
Page 8
Check whether the voltage of power supply in accordance with nameplate of machine. Assure the machine connect with grounding receptacle in case of fire or electric shock (ground wire color is yellow green). Power line must be ok to move freely. Avoid any squeezing on power line. ...
5.Starting and operating TAKE CARE! SCALD! The sealing blade can reach to the high temperature of more than 200℃ when it is heating sealing. Even after cooling, it is still in a high temperature. If you have any questions about the operation and the function that not offered in this ...
Page 10
Warning: the product inside of the bag must not cross this line, otherwise the equipment will be seriously damaged. Note: the part entered in the equipment must be kept flat and no paste. 图 3 Picture 3...
Page 11
Replacement for the fuse DANGER!ELECTRIC SHOCK! Please cut down the power before replacing the fuse. TAKE CARE!MACHINE DAMAGED! Different voltage or machine type equip with different fuse. To avoid the machine damage, please replace the fuse with same specifications and types. The main circuit fuse is located in the power socket.
Page 12
Adjustment for Embossing wheel pressure Inner Hexagon Spanner Compression Pin Protective Cover Remove the upper machine hull and protective cover. Loosen the nut with inner hexagon spanner. Adjust the compression pin with inner hexagon spanner. Lock nut after adjusting after the adjustment. ...
Page 13
Circlip for Holeφ26 Deep Groove Ball Bearing 6000 Rubber Space Ring of Embossing Wheel Loosen the set screw with inner hexagon spanner. Pull out the rubber wheel pin shaft. Take out rubber wheel assembly. Install the assembled rubber wheel assembly. ...
Need help?
Do you have a question about the HRS-255 and is the answer not in the manual?
Questions and answers