Installation manual
Daikin Altherma 3 R MT F
https://daikintechnicaldatahub.eu
ELVH12S18E▲6V▼
ELVH12S23E▲6V▼
ELVH12S18E▲9W▼
ELVH12S23E▲9W▼
ELVX12S18E▲6V▼
ELVX12S23E▲9V▼
ELVX12S18E▲9W▼
ELVX12S23E▲9W▼
Installation manual
English
▲= 1, 2, 3, ..., 9, A, B, C, ..., Z
Daikin Altherma 3 R MT F
▼= , , 1, 2, 3, ..., 9

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Altherma 3 R MT FELVH12S18E 6V Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin Altherma 3 R MT FELVH12S18E 6V Series

  • Page 1 Installation manual Daikin Altherma 3 R MT F https://daikintechnicaldatahub.eu ELVH12S18E▲6V▼ ELVH12S23E▲6V▼ ELVH12S18E▲9W▼ ELVH12S23E▲9W▼ ELVX12S18E▲6V▼ ELVX12S23E▲9V▼ ELVX12S18E▲9W▼ ELVX12S23E▲9W▼ Installation manual English ▲= 1, 2, 3, …, 9, A, B, C, …, Z Daikin Altherma 3 R MT F ▼= , , 1, 2, 3, …, 9...
  • Page 2: Table Of Contents

    To connect the backup heater power supply ....19 for basic and advanced usage 6.3.3 To connect the shut-off valve........20 ▪ Format: Digital files on https://www.daikin.eu. Use the search 6.3.4 To connect the electricity meters ........ 20 function to find your model.
  • Page 3: Specific Installer Safety Instructions

    Use a compatible counterpart for the chimney. Daikin website (publicly accessible). ▪ Make sure the connection is airtight. ▪ The full set of the latest technical data is available on the Daikin Business Portal (authentication required). ▪ The chimney material is unimportant.
  • Page 4: About The Box

    Handles at the bottom of the unit. Carefully tilt the unit the room when you purge air from the heat emitters or backwards so that the handles become visible. collectors. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 5: Unit Installation

    Make sure installation, servicing, maintenance and repair Minimum refrigerant piping length between indoor 3 m comply with instructions from Daikin and with applicable unit and outdoor unit legislation (for example national gas regulation) and are Maximum height difference between indoor unit and 30 m...
  • Page 6: Installation Patterns

    ▪ Unit's connection point for the chimney = 1" male thread. Use a compatible counterpart for the chimney. ▪ Make sure the connection is airtight. ▪ The chimney material is unimportant. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 7 ▪ Must be a permanent opening that cannot be closed. ▪ Must be ≥50% of A (minimum bottom opening area). nv-min Min. 50% ▪ Must be ≥1.5 m from the floor. of A nv-min (≥A nv-min ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 8 Ventilation openings must comply with A and with nv-min "Conditions ventilation openings" on previous page). Min. 50% Min. 50% ΔH1 of A of A nv-min nv-min (≥A (≥A nv-min nv-min Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 9 3.75 m 2.50 m 2.14 m 1.91 m 1.74 m 3.65 kg 3.96 m 2.64 m 2.26 m 2.02 m 1.84 m 1.71 m 3.85 kg 4.18 m 2.79 m 2.38 m 2.13 m 1.95 m 1.80 m 1.68 m 4.05 kg 4.40 m 2.93 m 2.51 m 2.24 m 2.05 m 1.89 m 1.77 m ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 10 1.86 m 5.369 dm² 3.401 dm² 2.562 dm² 1.789 dm² 1.002 dm² 0.209 dm² 2.06 m 4.700 dm² 2.629 dm² 1.681 dm² 0.809 dm² 2.26 m 4.103 dm² 1.934 dm² 0.886 dm² 2.46 m 3.565 dm² 1.302 dm² 0.160 dm² 2.66 m 3.074 dm² 0.721 dm² 2.86 m 2.624 dm² 0.183 dm² 3.06 m 2.206 dm² Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 11: Opening And Closing The Unit

    X 1 4 Y 3.25 kg 9.1 dm² 3.35 kg 9.2 dm² 3.45 kg 9.4 dm² 3.55 kg 9.5 dm² 3.65 kg 9.7 dm² 3 Remove the switch box cover. 3.75 kg 9.8 dm² 3.85 kg 9.9 dm² 3.95 kg 10.0 dm² 4.05 kg 10.2 dm² ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 12: To Lower The Switch Box

    The maximum allowed deviation is 1°. indoor unit. To have easier front access, hang the switch box outside the unit, over the high voltage switch box cover. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 13: To Connect The Drain Hose To The Drain

    ▪ with a heat resistance of at least 120°C ▪ Insulation thickness: Pipe outer diameter Insulation inner Insulation thickness (Ø diameter (Ø 6.4 mm (1/4") 8~10 mm 10 mm 15.9 mm (5/8") 16~20 mm 13 mm ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 14: Connecting Refrigerant Piping

    The following figure is an example and may NOT NOTICE completely match your system layout. Do NOT use excessive force when connecting the piping. Deformation of the piping can cause malfunctioning of the unit. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 15: To Connect The Recirculation Piping

    The recirculation connector is placed below the hole. pressure relief valve (field supply) and the DHW tank. 3 Route the recirculation piping through the grommet and connect it to the recirculation connector. ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 16: To Fill The Water Circuit

    If the supply cord is damaged, it MUST be replaced by the manufacturer, its service agent or similarly qualified Smart Grid "6.3.11 To connect a Smart Grid" [ 4  24]. persons in order to avoid a hazard. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 17 ▪ Addendum book optional ▪ Installation manual of the remote equipment indoor sensor ▪ Addendum book optional equipment Wires: 2×0.75 mm² [9.B.1]=2 (External sensor = Room) [1.7] Room sensor offset ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 18: To Connect The Main Power Supply

    Interconnection cable (=main power supply) Normal kWh rate power supply 1 2 3 Preferential power supply contact X11YB X11YA X11Y 3 Fix the cables with cable ties to the cable tie mountings. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 19: To Connect The Backup Heater Power Supply

    Z less than or equal to Z Connect the backup heater power supply as follows: ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 20: To Connect The Shut-Off Valve

    2 Connect the electricity meters cable to the appropriate terminals shown in the illustration below. as shown in the illustration below. NOTICE Wiring is different for a NC (normally closed) valve and a NO (normally open) valve. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 21: To Connect The Domestic Hot Water Pump

    Wires connected to the alarm output Wire between X2M and A4P A4P Installation of EKRP1HBAA is required. ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 22: To Connect The Space Cooling/Heating On/Off Output

    2 Connect the changeover to external heat source cable to the Wire between X2M and A4P appropriate terminals as shown in the illustration below. A4P Installation of EKRP1HBAA is required. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 23: To Connect The Power Consumption Digital Inputs

    2 Connect the safety thermostat (normally closed) cable to the appropriate terminals as shown in the illustration below. Note: The jumper wire (factory-mounted) must be removed from the respective terminals. ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 24: To Connect A Smart Grid

    Grid modes: Smart Grid contact Smart Grid operation mode Free running Forced off Recommended on Forced on The use of a Smart Grid pulse meter is not mandatory: Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 25 Wires between the relays and X5M (AWG22 ORG) Wires between the relays and X10M (AWG18 RED) High voltage Smart Grid contact 1 High voltage Smart Grid contact 2 ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 26: To Connect The Wlan Cartridge (Delivered As Accessory)

    The Installer pin code is 5678. Additional menu items and NOTICE installer settings are now available. This chapter explains only the basic configuration. For more detailed explanation and background information, see the installer reference guide. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 27: Configuration Wizard

    [9.2.1] [E‑05] 01 20 The backup heater will also be used [E‑06] for domestic hot water heating. [E‑07] 6 Press the left dial to confirm the new setting. ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 28 NOTICE main LWT zone. A differential pressure bypass valve can be integrated in the system. Keep in mind that this valve might not be shown on the illustrations. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 29: Configuration Wizard: Backup Heater

    ▪ Enable leaving water temperature modulation and the storage temperature setpoint is higher than 50°C, increase the maximum modulation [2.C]. Daikin recommends NOT to disable the backup heater second step because it will have a big impact on the Control required time for the unit to heat up the domestic hot water Define how the operation of the unit is controlled.
  • Page 30: Configuration Wizard: Additional Zone

    The maximum allowed temperature is determined by the zone" [ 4  29]. wizard: Main following setting: Code Description [3.7] [2‑0D] ▪ 0: Underfloor heating ▪ 1: Fancoil unit ▪ 2: Radiator Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 31: Weather-Dependent Curve

    When the tank temperature drops below the reheat temperature minus the reheat hysteresis temperature, the tank heats up to the reheat temperature. Code Description [5.A] [6-08] Reheat hysteresis ▪ 2°C~20°C ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 32: Slope-Offset Curve

    To change the type of weather-dependent curve To change the type for all zones (main + additional) and for the tank, go to [2.E] Main zone > WD curve type. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 33: Settings Menu

    Cold Cold ↑ ↑ ↑ ↑ Cold ↓ ↑ ↓ ↑ — ↓ — ↓ Cold ↑ ↓ ↑ ↓ ↓ ↓ ↓ ↓ curve" [ 4  31]. "7.3.2 2-points ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 34: Menu Structure: Overview Installer Settings

    Solar kit settings are shown but are NOT applicable for this unit. Settings shall NOT be used or changed. INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 35: Commissioning

    Next ▪ Between the local supply panel and the indoor unit commissioning instructions in this chapter, a general commissioning checklist is also available on the Daikin ▪ Between the indoor unit and the valves (if applicable) Business Portal (authentication required).
  • Page 36: To Check The Minimum Flow Rate

    ▪ Bizone mixed pump test (bizone kit EKMIKPOA or 3 Select a test from the list. Example: Heating. EKMIKPHA) ▪ Bizone mixing valve test (bizone kit EKMIKPOA or EKMIKPHA) Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 37: To Perform An Underfloor Heating Screed Dryout

    ▪ Show the user what to do for the maintenance of the unit. ▪ Explain about energy saving tips to the user as described in the operation manual. ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 38: 10 Technical Data

    10 Technical data Technical data A subset of the latest technical data is available on the regional Daikin website (publicly accessible). The full set of the latest technical data is available on the Daikin Business Portal (authentication required). 10.1 Piping diagram: Indoor unit...
  • Page 39: Wiring Diagram: Indoor Unit

    Translation of text on wiring diagram Position in switch box English Translation English Translation (1) Main power connection (1) Main power connection Position in switch box Position in switch box ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 40 Switch box (7) Option PCBs (7) Option PCBs Alarm output Alarm output Changeover to ext. heat source Changeover to external heat source Max. load Maximum load Installation manual ELVH/X12S18+23E Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 41 10 Technical data Electrical connection diagram For more details, please check the unit wiring. ELVH/X12S18+23E Installation manual Daikin Altherma 3 R MT F 4P708472-1A – 2024.12...
  • Page 44 4P708472-1 A 0000000+ 4P708472-1A 2024.12...