Stelpro UNIWATT UWAC05KMC110E Owner's Manual
Stelpro UNIWATT UWAC05KMC110E Owner's Manual

Stelpro UNIWATT UWAC05KMC110E Owner's Manual

Window air conditioner

Advertisement

Quick Links

OWNER'S
MANUAL
UWAC
WINDOW AIR CONDITIONER
UWAC05KMC110E
THANK YOU FOR YOUR PURCHASE!
QUESTION? PROBLEM?
CONTACT STELPRO CUSTOMER SERVICE.
WWW.UNIWATT.CA
CONTACT@STELPRO.COM
1-844-STELPRO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UNIWATT UWAC05KMC110E and is the answer not in the manual?

Questions and answers

Summary of Contents for Stelpro UNIWATT UWAC05KMC110E

  • Page 1 OWNER'S MANUAL UWAC WINDOW AIR CONDITIONER UWAC05KMC110E THANK YOU FOR YOUR PURCHASE! QUESTION? PROBLEM? CONTACT STELPRO CUSTOMER SERVICE. WWW.UNIWATT.CA CONTACT@STELPRO.COM 1-844-STELPRO...
  • Page 2: Table Of Contents

    CONTENT IMPORTANT INSTRUCTIONS .................... 3 Introduction to Refrigerants R32................... 4 Electrical Requirements ....................5 Electrical Shock ......................5 Recommended Ground Method ................... 5 LCDI Power Cord and Plug .................... 6 To test the plug ......................6 INSTALLING THE AIR CONDITIONER................7 Parts name ........................
  • Page 3: Important Instructions

    IMPORTANT INSTRUCTIONS Before installing and using your air conditioner, please read this owner's manual carefully. Store this manual in a safe place for future reference. Your safety and the safety of others is very important to us. Please pay attention to all safety messages outlined in this user manual.
  • Page 4: Introduction To Refrigerants R32

    INTRODUCTION TO R32 REFRIGERANTS The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This kind of erant is combustible and odorless. Moreover, it can burn and explode under certain condition. However, there will be no risk of burning and explosion if you comply with the following table to install your air conditioner in a room with an appropriate area and use it correctly.
  • Page 5: Electrical Requirements

    ELECTRICAL REQUIREMENTS WARNING ELECTRICAL SHOCK HAZARD • Your air conditioner must be plugged into a properly grounded wall outlet. If the outlet you wish to use is not properly grounded or protected by a fuse or circuit breaker, have a qualified electrician install the appropriate outlet •...
  • Page 6: Lcdi Power Cord And Plug

    LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
  • Page 7: Installing The Air Conditioner

    INSTALLING THE AIR CONDITIONER PARTS NAME 1 Window Air Conditioner 1 Top Rail (With sponge) 2 Lock Frame 2 Filler Panels (With "Left" & "Right" remark on the front face) 1 Sash Lock 1 Window Sash Seal 1 Foam Top (Two holes) (Sponge) Window Gasket...
  • Page 8 Some assembly is required for your new air conditioner. Please read and follow these instructions carefully. • This air conditioner is designed to be installed in a standard double-hung window with a window width between 23" (584mm ) and 34" (863 mm). •...
  • Page 9: Top Rail Assembly

    TOP RAIL ASSEMBLY The top rail must be assembled prior to installing the air conditioner in the window. Tools Needed: Phillips Head Screw Driver ATTACHING THE TOP RAIL TO THE AIR CONDITIONER • Remove the air conditioner from the box and place on a hard and flat surface. •...
  • Page 10: Accordion Panel Installation

    INSTALLATION OF ACCORDION PANELS Now that you have installed the top rail, you can now install the accordion panels on each side. 1. Place unit on floor, a bench or a table. 2. There is a Left and Right Window Filler Panel be sure to use the proper panel for each side.
  • Page 11: Requirements For Storm Windows

    REQUIREMENTS FOR STORM WINDOWS A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly. To adjust for this, attach a board or piece of wood to the sill. The board or wood piece should have a depth of at least 1-1/2" (38 mm). Make sure the board or piece of wood is approximately 1/2"...
  • Page 12: Frame Lock, Sash Lock, And Foam Seal Installation

    3. Once the air conditioner is placed, extend both the left and right accordion panels to the width of the window. (Fig. 11) Fig. 11 FRAME LOCK, SASH LOCK, AND FOAM SEAL INSTALLATION Tools Needed: • Phillips Head Screw Driver • Drill (if plot holes are needed) 1.
  • Page 13: Removing The Air Conditioner From The Window

    3. Drive 1/2" (13 mm) screws into the top of the accordion panel frame and the top rail to securely attach the window air conditioner to the lower sash. (Fig.14 and Fig.15) Fig. 14 Fig. 15 4. To secure the lower sash into place, use the sash lock and a 3/4" (19 mm) screw as shown below.
  • Page 14: Introduction To Refrigerants R32

    INTRODUCTION TO R32 REFRIGERANTS THESE OPERATIONS MUST BE CARRIED OUT BY QUALIFIED PERSONNEL ONLY. • Before installing the appliance, you must read the manual carefully to get the safety information and notes. • When filling the combustible refrigerant, any of your rude operations may cause serious injury or injuries to human body or bodies and object or objects.
  • Page 15 Please note that: • The installation site should be in a well-ventilated condition. • The sites for installing and maintaining an air conditioner using R32 refrigerant should be free from open fire or welding, smoking, drying oven or any other heat source higher than 548°C which easily produces open fire.
  • Page 16: Using Your Air Conditioner

    USING THE AIR CONDITIONER NORMAL OPERATING SOUNDS • You may hear a pinging noise caused by water hitting the condenser, on rainy days, or when the humidity is high. This design feature helps remove moisture and improve efficiency. • You may hear the thermostat click when the compressor cycles on and off. •...
  • Page 17: Cleaning And Maintenance

    CLEANING AND MAINTENANCE The air filter should be checked at least once every month to see if it needs cleaning. Trapped particles and dust can build up in the filter and may decrease airflow as well as cause the cooling coils to accumulate frost. TO CLEAN THE AIR FILTER •...
  • Page 18: Troubleshooting

    TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS Make sure the air conditioner The air conditioner plug is pushed completely into is unplugged the outlet. Check the house fuse/circuit The fuse is blown/circuit breaker box and replace the breaker is tripped fuse or reset the breaker. The unit will automatically re- start when power is restored There is a protective time...
  • Page 19 PROBLEM POSSIBLE CAUSES SOLUTIONS Set the MODE dial to HIGH Ice blocks the air flow The Air Conditioner FAN or HIGH COOL and set and stops the air conditioner is freezing up the thermostat to a higher from cooling the room temperature.
  • Page 20: Assistance

    ASSISTANCE Distribué par Stelpro Design inc. www.stelpro.com contact@stelpro.com 1 844-STELPRO Before returning the unit to the retailer, for any problem related to the installation, use or proper functioning of the unit; contact our customer support department. One of our agents will guide you through the next steps.