Summary of Contents for sterling water treatment DSF-PFOA

  • Page 1 INSTALLATION MANUAL DSF-PFOA Point-of-Use PFA’s Reduction System Franklin Electric Co., Inc. 12630 US 33 N. Churubusco, IN 46723 Ph. (260) 693-1972 Fax (260) 693-0602 DS-PFOA Manual 250128.docx...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS: SECTION I. INTRODUCTION AND LIABILITY..........3 SECTION II. SPECIFICATIONS..............3 SECTION III: PREPARATION.................4 Major System Components......................4 B. Tools Recommended for Installation..................4 C. Determine System Location......................4 D. Prepare the Area for Installation....................5 E. Prepare the Appliance for Installation..................5 SECTION IV. INSTALLATION STEPS............5 A.
  • Page 3: Introduction And Liability

    Your new PFA’s Reduction (DSF-PFOA) Drinking Water system uses a combination of Ion Exchange Resin and a carbon block filter to remove the widest range of PFA’s found in our drinking water.
  • Page 4: Preparation

    SECTION III: PREPARATION C. Determine System Location The DSF-PFOA system can be located under a A. Major System Components sink or in a basement depending on space availability and the customer’s preference. If a The following components comprise the DSF-...
  • Page 5: Prepare The Area For Installation

    Open shipping carton and remove components. Check that all installation parts are present which IMPORTANT: It is mandatory that safety glasses includes the DSF-PFOA assembly, water meter, be worn during sink hole drilling operations to faucet, installation hardware, leak stop valve, prevent eye injury.
  • Page 6: Mount The Faucet

    PORCELAIN/ENAMEL/CERAMIC ON SHEET c) Connect length of standard 1/4" tubing to METAL OR CAST IRON BASE: faucet. Ensure plastic insert is in tubing. Push on firmly until it seats. Recommended tools: d) Feed the threaded nipple through • sink/counter mounting hole and orient the Variable speed drill faucet as discussed with the customer.
  • Page 7: Automatic Water Meter

    DSF-PFOA housing assembly. This will allow for ease of setting the F. Install Ice Maker Hookup (optional) meter in gallons.
  • Page 8: Section V: Operation & Maintenance

    A. Changing Filter the dispensing faucet, close the faucet. Let the system stand for 15 minutes. NOTE: THIS DSF-PFOA SYSTEM CONTAINS At the end of the 15 minutes, in the FILTERS WHICH MUST BE REPLACED AT following order, open the ball valve;...
  • Page 9: Exploded Diagram

    B. Exploded Diagram...
  • Page 10: Parts List

    PFA’s Parts List REF# Part # Description RO-FWV Feed Water Valve, 3/8"Mx1/2"Fx1/4"Tube, w/1/2"Mx3/8"F Adapt. RO-LSV Leak Stop Valve for RO System BV-101 Ball Valve, 1/4" tube x 1/4" tube 4ME4-1 Male Elbow, 1/4" Tube x 1/4" M W905-WF14 10" SLIM 905 HSG, WHITE SUMP AF-10-3612 2.5"...
  • Page 11: Quick Connect Fittings

    TO ATTACH TUBING... C. Quick Connect Fittings Your new DSF-PFOA Drinking Water Appliance is outfitted with new generation of user-friendly quick connect push-in fittings. Proper use of the fittings is shown in the diagrams. It is important that the tubing selected for use with these connectors be of high-quality exact size and roundness, and with no surface nicks or scratches.
  • Page 12: Section Vi: Troubleshooting Guide

    SECTION VI. TROUBLE SHOOTING GUIDE Problem Possible Cause Solution Low quantity of Product Feed Water Valve is plugged or Open Valve or unclog. Water from Treatment closed. System or Low Pressure Flow Control is plugged. Replace Flow control or unclog. at the Dispensing Faucet Clogged filter.
  • Page 13: Leak Stop Valve Compressed Pellet Replacement

    Leak Stop Valve – Compressed Pellet Replacement 1) Pull the upper cover upward and separate it from the lower body. 2) Remove the expanded pellet from the retainer. 3) Replace the expanded pellet with the spare compressed pellet. 4) Seat the compressed pellet and retainer into the lower body. 5) Push the upper cover down until it snaps securely in place.
  • Page 14: Limited Warranty

    PFA’S DRINKING WATER SYSTEM LIMITED WARRANTY What Does This Warranty Cover? This warranty covers any defects in materials and workmanship of the PFA’s Drinking Water System when installed and operated within recommended parameters, with the exceptions stated below. How Long Does The Coverage Last? The manufacturer will warrant its PFA’s Drinking Water System, for a period of one year from the date of purchase.