HEAT PUMP REXNORDIC HP-60 Mobile Heat Pump Thank you for purchasing the unit. Before operation, please read this user’s manual carefully. INSTRUCTION OHJEKIRJA BOOK BRUKSAN- INSTRUKSJONS- INSTRUKTIONS- BEDIENUNGS- INSTRUCTIE- VISNING ANLEITUNG BOEK MANUEL INSTRUKCJA MANUALE DI MANUAL DE IN- MANUAL DE D’INSTRUCTIONS...
TABLE OF CONTENTS SAFETY INSTRUCTIONS SPECIFICATIONS, CONTROL PANEL FUNCTIONS GENERAL ADVICE BEFORE USE EXTERIOR DESCRIPTION MODE CHANGING METHOD HOW TO SET THE ‘OFF’ TIMER TEMPERATURE CONTROL OPERATION SELECTION ‘ERROR’ and WARNING INDICATORS TROUBLE SHOOTING CLEANING AND MAINTENANCE USING MOBILE APPLICATION WIRING DIAGRAM THE INSTALLATION, SERVICE AND OPERATION MANUAL Thank you for purchasing the unit.
SAFETY INSTRUCTIONS INSTALLATION WARNING Keep this manual in a visible WARNINGS REGARDING PROPER LOCATION location near the unit for easy reference. FOR INSTALLATION Do not use the unit in explosive environ- WARNING SYMBOLS: YOU MUST YOU MUST NOT. ments or in areas where flammable gas leakage may occur.
INSTRUCTION BOOK CONTROL PANEL FUNCTIONS Power Use to power on / off. Fan Speed Controls fan low / high speed. ⑦ ⑧ ⑨ Raises or lowers the setting ▼▲ Button temperature or sleep (off) time. Mode Use to select Cooling / Dehumidification / Fan / Heating / Auto mode Off Timer You can set the time to stop the unit.
GENERAL ADVICE BEFORE USE MODE CHANGING METHOD • Ensure the safety of the location in which the unit is to be used. COOLING MODE • Ensure the floor or ground is smooth and flat. If you press the ‘Mode’ button. ‘Cooling sym- •...
HOW TO SET THE ‘OFF’ TIMER TEMPERATURE CONTROL OPERATION This function enables you to set the length •When you turn ON, the set- of time you want the unit to operate. ting temperature is displayed. • You can change setting temperature.
SELECTION ‘ERROR’ AND WARNING INDICATORS SPOT OR ROOM MODE ERROR CODE PROBLEM CAUSE To change the temperature of the entire room, High Blocked COND filter. select ‘Room mode’. For pressure Blocked / kinked ex- targeted cooling of haust duct.Ambient machinery servers or people temperature is too etc select high.
‘ERROR’ AND WARNING INDICATORS TROUBLE SHOOTING ERROR CODE PROBLEM CAUSE TROUBLE CHECK REMEDY If the AF2 sensor is Power cable Connect cable WORKING sensor shortcircuited or cut correctly correctly. ‘E3 A2’displayed and connected. the ‘Error’LED will Power button Press POWER be on.
CLEANING AND MAINTENANCE ● CLEANING THE AIR FILTERS CLEANING AND MAINTENANCE 1. To remove filters, slide up 2. Clean the filters w ① a little ① and pull towards you ②. or compressed air ② ● MAINTENANCE CLEANING THE AIR FILTERS 1.
REGISTER AS A USER TO APPLICATION On the login screen, press JOIN button to start a new user registration. If you already have an Rex Nordic account, sign in with your email and password. Please read all terms of service and accept them by clicking ACCEPT button.
Page 12
USING MOBILE APPLICATION CONNECTING THE HEAT PUMP TO APPLICATION CONNECTING HEATPUMP TO APPLICATION Fill in the Rex Nordic 3 Press the location cursor years warranty form. Remember to provide location information to fill in all information. to the application. If you don’t want to register your HP...
BLE. 6. Product operating status 7. Turn off HP - Rex Nordic mobile application supports Android version 5.1and 8. Swipe down for reloading later. For iPhone the application supports iOS version 10 and product status later and iPhone 7 or later.
THE INSTALLATION, SERVICE REFRIGERANTS to show that flammables may be dangerous when handled without care. AND OPERATION MANUAL • Information about POTENTIAL IGNITION SOURCES, especially those that are not obvious, such as lighters, light switches, vacuum cleaners, electric heaters. • Information about the different safety concepts: Ventilated enclosure –...
Page 16
– Purge the refrigerant circuit with oxygen free nitrogen; 2. General work area – Evacuate the refrigerant circuit; All maintenance staff and others working in the local area shall be – Purge the refrigerant circuit with nitrogen for 5 min (not required instructed on the nature of work being carried out.
Page 17
fault exists that could compromise safety, then no electrical supply but, in the case of FLAMMABLE REFRIGERANTS, the sensitivity may shall be connected to the circuit until it is satisfactorily dealt with. not be adequate, or may need re-calibration. If the fault cannot be corrected immediately but it is necessary to (Detection equipment shall be calibrated in a refrigerant-free continue operation, an adequate temporary solution shall be used.
Page 18
takes place. Attention is drawn to the fact that additional transportation g) Start the recovery machine and operate in accordance with regulations may exist with respect to equipment containing instructions. flammable gas. h) Do not overfill cylinders (no more than 80 % volume liquid The maximum number of pieces of equipment or the configuration charge).