Oregon Scientific BAA898HG User Manual
Oregon Scientific BAA898HG User Manual

Oregon Scientific BAA898HG User Manual

Long-range wireless weather station with in-out thermo-hygrometer

Advertisement

LONG-RANGE WIRELESS WEATHER STATION
INTRODUCTION
Congratulations on your purchase of the BAA898HG Long-Range
Wireless Weather Station with In-Out Thermo-Hygrometer. This
unit is an all-in-one weather forecasting device which has multiple
weather-related functions. Also, with an internal antenna the
reception range of this unit can be up to 100 meters.
In addition to indoor temperature and humidity, by means of
wireless remote thermo-hygro sensor it can simultaneously
monitor temperatures and humidities in up to 3 remote locations.
The unit will show temperature and humidity trends as well as
record maximum and minimum temperature and humidity
readings.
As part of the weather forecasting function, the unit has a built-
in barometer that displays atmospheric pressure. Using kinetic-
movement graphic illustrations the unit displays atmospheric
pressure trends and displays forecasts as sunny, partly cloudy,
cloudy, rainy and snowy.
WITH IN-OUT THERMO-HYGROMETER
MODEL : BAA898HG
USER'S MANUAL
Other features of BAA898HG include LCD and key-panel backlight,
rotatable display unit for multi-angle viewing and a Daily
crescendo alarm and Pre-alarm function with an eight-minute
snooze function.
No wire installation is required between the main and remote
units as this unit operates at 433 MHz.
1

Advertisement

Table of Contents
loading

Summary of Contents for Oregon Scientific BAA898HG

  • Page 1 LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER MODEL : BAA898HG USER'S MANUAL Other features of BAA898HG include LCD and key-panel backlight, INTRODUCTION rotatable display unit for multi-angle viewing and a Daily crescendo alarm and Pre-alarm function with an eight-minute Congratulations on your purchase of the BAA898HG Long-Range snooze function.
  • Page 2: Features : Main Unit

    B. CONTROL BUTTONS - FRONT PANEL FEATURES : MAIN UNIT B1. [ MODE ] BUTTON A. LCD DISPLAY - Changes the display mode of the clock, and alters time/ A1. WEATHER FORECAST WINDOW date setting - Graphically illustrates a weather forecast B2.
  • Page 3: Control Buttons - Side Panel

    B3. [ MEMORY ] BUTTON - Displays minimum and maximum temperature and humidity readings, and erases memory data B4. [ CHANNEL ] BUTTON - Displays the temperature and humidity readings of the indoor or remote sensor B5. [ SNOOZE / LIGHT ] BUTTON - Activates the snooze function or turn on the backlight B6.
  • Page 4: Features : Remote Thermo-Hygro Sensor Thgr228N

    D3. [ mb / hPa - inHg ] SLIDE SWITCH - Selects between "mb / hPa" or "inHg" pressure unit display D4. [ °C / °F ] SLIDE SWITCH - Selects between Centigrade (°C ) or Fahrenheit (°F) temperature unit display D5.
  • Page 5: Before You Begin - Installing The Table Stand

    2. Position the remote unit and the main unit within effective BEFORE YOU BEGIN - transmission range. In usual circumstances, the effective range INSTALLING THE TABLE STAND is up to 100 meters. 3. Though the remote unit is weather proof, it should be placed Before operation, plug away form direct sunlight, rain or snow.
  • Page 6: Lcd And Key-Panel Backlight

    Follow these steps to install / replace batteries: Wall-Mount Table-Stand 1. Remove the screws on the battery compartment. 2. Select the channel number on the CHANNEL slide switch. 3. Select the temperature display unit on the °C/°F slide switch. Press the corresponding [ SNOOZE / LIGHT ] button or stand- button once.
  • Page 7: Alarm And Snooze Function

    5. For the language for day-of-week, you can select E for English, 3. Press [ ] or [ ] buttons to make changes to the alarm hour D for German, F for French, I for Italian or S for Spanish. The setting.
  • Page 8: Note On Remote Readings

    minutes, the pre-alarm will start to operate at 6:15 am (45 minutes PRE-ALARM FUNCTION FOR before 7:00 am). The Pre-Alarm icon will flash and the backlight CHANNEL 1 REMOTE SENSOR will be turned on for 5 seconds. An alarm sound will also go off for 2 minutes as that of the daily alarm and the snooze function The alarm function also has a pre-alarm feature which can alert the will also be activated if the [ SNOOZE / LIGHT ] button or stand-...
  • Page 9: Temperature & Humidity Trend

    The temperature can be shown in Centigrade (°C) or Fahrenheit erased. Subsequently, if you press [ MEMORY ] after the memory (°F). Select the appropriate reading by using the [ °C / °F ] slide has been erased, the maximum and minimum readings will have switch (located in the battery compartment).
  • Page 10: Comfort Level Indicators

    COMFORT LEVEL INDICATORS Arrow indicator The comfort level indicators COM, WET or DRY will tell you if the current environment is comfortable, too wet or too dry. Pressure R i s i n g Steady Falling Trend The comfort indicator will appear on the display when the following conditions are satisfied: WEATHER FORECAST Indicator...
  • Page 11: How To Check The Barometric Pressure

    HOW TO CHECK HOW TO WALL MOUNT OR USE THE THE BAROMETRIC PRESSURE TABLE STAND (REMOTE UNIT) The current and historical barometric pressure is shown on the As for the remote unit, it comes with a wall-mount holder and a atmospheric pressure window.
  • Page 12: How To Reset The Unit

    Wall-Mount: Table-Stand: MAINTENANCE Gently plug in the table stand When handled properly, this unit is engineered to give you years as shown: of satisfactory service. Here are a few product care instructions: 1. Do not immerse the unit in water. If the unit comes in contact with water, dry it immediately with a soft lint-free cloth.
  • Page 13 Relative Humidity measurement Remote sensing unit : uses two (2) UM-4 or "AAA" 1.5V batteries Measuring Range : 25% RH to 95% RH at 25°C (77°F) Humidity Resolution : 1% RH Weight Main unit : 300gm (without battery) Remote unit Remote sensing unit : 63gm (without battery) RF Transmission Frequency : 433 MHz...
  • Page 14: Ec Declaration Of Conformity

    EC-DECLARATION OF CONFORMITY This product contains the approved transmitter module TX 01 and complies with the essential requirements of Article 3 of the R&TTE 1999/5/EC RTTE Compliant Countries : Directives, if used for its intended use and that the following standard(s) has/ All EC countries, Switzerland have been applied: And Norway...