DIGITAL WEATHER FORECASTER
WITH REMOTE THERMO-HYGRO
SENSOR AND
MODEL NO.: BAA182HG
USER'S MANUAL
INTRODUCTION
Congratulations on your purchase of the Weather forecaster with
cable free sensor
and clock
(BAR182HG).
This unit has a large four-line liquid crystal display (LCD) for
displaying weather forecast information, in/outdoor temperatures
and relative
humidity, calendar
zone and dual daily alarms. Also, the main unit can support up to
three remote sensors.
Other features include weekday display in four abbreviated
languages, crescendo alarm and interchangeable clock display
modes.
ALARM
CLOCK
clock, clock display of 2nd time-
MAIN FEATURES: MAIN UNIT
H
A
A1
B
O
L
M
N
1
C
D
E
F
G
P
I
RESET
ON
ON / / OFF
OFF
J
K
ON
ON / / OFF
OFF
HI
HI / / LO
Q
R

Advertisement

Table of Contents
loading

Summary of Contents for Oregon Scientific BAR182HG

  • Page 1 USER’S MANUAL INTRODUCTION Congratulations on your purchase of the Weather forecaster with cable free sensor and clock (BAR182HG). This unit has a large four-line liquid crystal display (LCD) for displaying weather forecast information, in/outdoor temperatures and relative humidity, calendar clock, clock display of 2nd time- zone and dual daily alarms.
  • Page 2 A . FRONT DISPLAY A four line easy-to-read LCD A1. WEATHER FORECAST WINDOW Graphically illustrates a weather forecast B. [ ] BATTERY-LOW INDICATOR Activates when the remote-sensor or main unit battery power is low C. [ ] / [ ] ALARM-ON ICONS Appears when the alarm is activated D.
  • Page 3: Features: Remote Thermo-Hygro Sensor

    FEATURES: REMOTE THERMO-HYGRO SENSOR TWO-LINE LCD Displays the current temperature and humidity monitored by the remote unit LED INDICATOR Flashes when the remote sensor transmits a reading °C/°F SLIDE SWITCH Selects between Centigrade (°C) and Fahrenheit (°F) CHANNEL SLIDE SWITCH Select the remote sensor Channel 1, Channel 2 or Channel 3 RESET Returns all user programmed settings to original factory set...
  • Page 4: Battery And Channel Installation: Remote Unit

    easier synchronization between the transmission and reception of signals. 4. Position the remote unit and main unit within effective transmission range, which, in usual circumstances, is up to 30 meters. Note that the effective range is vastly affected by the building materials and where the main and remote units are positioned.
  • Page 5: Low Battery Warning

    LOW BATTERY WARNING When it is time to replace batteries, the respective low-battery indicator will show up when the respective channel is selected. HOW TO USE THE TABLE STAND OR WALL MOUNTING The main unit has a removable table stand, which when connected, can support the unit on a flat surface.
  • Page 6: How To Check Remote And Indoor Temperature & Humidity

    To force a signal search: Press and hold [CHANNEL] & [MEM] for 2-seconds to enforce a 3-minute search. This is useful in synchronizing the transmission and reception of the remote and main units. Repeat this step whenever you find discrepancies between the reading shown on the main unit and that on the respective remote unit.
  • Page 7: How To Read The Kinetic Wave Display

    HOW TO READ THE KINETIC WAVE DISPLAY The kinetic wave display shows the signal receiving status of the main unit. There are three possible forms: The unit is in searching mode. Transmission data are securely registered. No signal received in search mode. REMOTE SENSOR SCANNING The unit can be set to automatically scan and display readings from the remote sensors and indoor readings.
  • Page 8: Temperature, Humidity & Pressure Trend Indicators

    TEMPERATURE, HUMIDITY & PRESSURE TREND INDICATORS The temperature-trend, humidity-trend and pressure trend indicators show the trends of collected readings. Arrows indicate a rising, steady or falling trend. Arrow indicator Temperature Rising Trend Arrow indicator Humidity Trend Rising Arrow indicator Pressure Trend Rising Note: If the readings goes above or below the measuring range of the main unit or the remote unit ( stated in specification), the display...
  • Page 9: Weather Forecast Function

    The high-low displays are as follows: Sequence Respective Display Pressing HI/LO once Enters HI temperature display Pressing HI/LO twice Enters HI humidity display Pressing HI/LO third time Enters LO temperature display Pressing HI/LO fourth time Enters LO humidity display To set a high or low temperature or humidity alarm: 1.
  • Page 10: Calendar Clock Display Modes

    Indicator displays on the unit Forecast Sunny Slightly Cloudy NOTE: 1. The accuracy of a general pressure-based weather forecast is about 70% to 75%. 2. The weather forecasts from this unit are predictions that cover the next 12 to 24 hours. It may not necessarily reflect the current situation.
  • Page 11: How To Set And Arm The Alarms

    For the 2nd time zone, which is indicated by the ZONE icon, enter the hour offset using the [ ] and [ BAA182HG will calculate the second zone-time accordingly. If there is an item you do not wish to change, simply press [ MODE] to bypass the item.
  • Page 12: Maintenance

    MAINTENANCE When handled properly, this unit is engineered to give you years of satisfactory service. Here are a few product care instructions: 1. Do not immerse the unit in water. If the unit comes in contact with water, dry it immediately with a soft lint-free cloth. 2.
  • Page 13: Note On Compliance

    Consult the dealer of an experienced radio/TV technician for help. Company Name: Oregon Scientific, Inc. Address: 19861 SW 95th Place, Tualatin, Oregon 97062, USA Telephone Number: 1-800-853-8883 Name and model number of the product: Weather Station...
  • Page 14: Warranty

    Please retain your retail receipt as you may be asked to provide a copy of it for proof of date purchased. This warranty does not cover product subjected to abuse, misuse, accidental damage or tampering. ©2003.Oregon Scientific.All rights reserved.

This manual is also suitable for:

Baa182hg

Table of Contents