Summary of Contents for Veichi Electric VM-1600END
Page 1
Manual Version V1.1 Archived Date 2023-03-07 Veichi Electric Co., Ltd. provides customers with a full range of technical support, so users can reach the nearest Veichi Electric Co., Ltd. office or customer service center, or the company headquarters directly. Veichi Electric Co.
⚫ Scan the QR code on the product body to get the manual with mobile phone. ◼ Warranty Statement If malfunctions or damage occur on the product under normal use, Veichi Electric offers 18-month warranty (from the date of shipment from the factory, subject to the bar code on the body, and in accordance with the agreements between parties if there are some).
Page 3
The relevant service costs are calculated according to the manufacturer's standards, and if there is a contract, the contract will be handled on a priority basis. Please refer to the Product Warranty Card for detailed warranty description.
Safety Precaution ◼ Safety Statement ⚫ Read and follow these safety precautions before installing, operating, and maintaining the product. ⚫ Follow all safety precautions stated on the product's labeling and in the manual when installing, operating, and maintaining the product for personal and equipment safety. ⚫...
➢ Design external protection circuits and safety mechanisms for output signals related to major accidents for safe operation of the equipment; ➢ The programmable controller CPU may stop all output when it detects an abnormality in its own system; when some of the controller's circuits fail, output may turn uncontrolled. Please design suitable external control circuits in order to ensure normal operation;...
➢ Wiring of this product should only be carried out by specialized maintenance personnel with adequate electrical knowledge and training related to electrical equipment; ➢ During wiring, the external supply power to the system must be fully disconnected in advance. Failure to do so may result in electric shock or equipment failure or malfunction;...
Page 7
➢ Dispose of this product as industrial waste, and the batteries should be handled separately in accordance with local laws and regulations; ➢ Dispose of equipment and products in accordance with industrial waste disposal standards to avoid environmental pollution.
Model Description Machine code Application VM-1600END series 16-channel VM-series PLC, digital input VM-series coupler 1.2 Component Description Interface Function definition Signal Power/Run On (green) Module working indicator (POWER+RUN) indicator properly. Module is abnormal. Flashing Module is in ready or (green) stop state.
Orange: temperature measurement input User terminal See the terminal definition section for details. 1.3 Specification 1.3.1 Power Specification Item Specification Rated voltage of terminal input voltage 24V DC (20.4V DC~ 28.8V DC) Rated current of terminal input power 2A (typical at 24V) Rated voltage of bus input power 5V DC (4.75V DC~5.25V DC) Rated current of bus input power...
Input derating 75% derating at 55° C (with no more than 12 input terminals while ON), or 10° C derating when input terminals are all ON 1.3.3 Software Specification Item Specification Software input filter time 0.25ms*N (N=0~255) 8 channels per group, and every group shares one filter parameter Abnormality detection and indication of input None...
2.2 Installation 2.2.1 Inter-module Installation Inter-module assemblies are slide-mounted via the top and bottom rails. 2.2.2 Rail Installation DIN rail mounting is adopted here. When installing, align the module with the DIN rail and press the snap until there is a clear click sound. As shown in the figure below. Note: Push the rail snaps first to open state, place the module onto the DIN rail, press down the top of the snaps with your hand until it is in place.
Page 14
module and when install them, hook the bottom of the DIN rail clamp to the bottom of the DIN rail and then rotate the DIN rail clamp so that the top end of the DIN rail clamp is hooked to the top end of the DIN rail, and then finally tighten the screws to lock the DIN rail clamp.
3 Electrical Installation 3.1 Cable Selection The wire lug diameters in the following table are for reference only, and can be adjusted according to reasonable calculations based on practical use. Material name Wire diameter PRC standard /mm2 American standard (US) /AWG Tube lug 0.75 If other tube lugs are used, crimp them to the stranded wire, shape and size are required as shown...
Page 18
4 Module Programming Example 4.1 Veichi Auto Studio with VC5 4.1.1 Create A New Project 4.1.2 Configure EtherCAT Task...
Page 19
4.1.3 Import the xml File Import the current latest version of VM-RTU-ECT_1.0.0.xml description file and double click to add it to the device:...
4.1.4 Slot Configuration Currently, VC5 requires slot configuration of the device first, and the configuration of the expansion modules and the order must be consistent with the physical object, otherwise an alarm will pop up to indicate that the configuration does not match what is connected. 4.1.5 IO Mapping VC5 default setting is no mapping, so it is necessary to map the registers that will be controlled and monitored to the soft components before actual use, otherwise users can’t operate on them.
Page 21
4.1.6 Set Parameters filtertime: digital input filter parameters (index number in the EtherCAT application: 0x8000+0x40*slot number), 8-channel outputs share one set of filter parameters, two independent filter parameters can be set corresponding to CH0 and CH1 respectively. Unit 0.25ms, setting range 0~255, i.e. 0.25ms*N (N=0~255).
Page 22
Copy the current latest version of the description file VM-RTU-ECT_1.0.0.xml to the TwinCAT installation directory under TwinCAT\3.1\Config\Io\EtherCAT. 4.2.2 Create A New TwinCAT Project Open the TwinCAT software to create a new TwinCAT project, connect the VM-RTU-ECT to the VM-1600END and power up and connect it to the Ethernet interface of the PC.
Page 23
4.2.3 Scan the Devices Ensure that the VM-RTU-ECT and VM-1600END are connected for device scanning, and follow the pop-up confirmation to make it run to OP. Note: A new installation of TwinCAT software requires the installation of the real-time NIC driver before this step.
Need help?
Do you have a question about the VM-1600END and is the answer not in the manual?
Questions and answers