Download Print this page
GE AKCQ10D Owner's Manual & Installation Instructions
GE AKCQ10D Owner's Manual & Installation Instructions

GE AKCQ10D Owner's Manual & Installation Instructions

24” through-the-wall air conditioner

Advertisement

Quick Links

CONSUMER SUPPORT
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Consumer Support . . . . . . . . . . . . . . . . . . . 20
Write the model and serial
numbers here:
Model # _________________
Serial # _________________
You can find the this information
on a label attached to the right
side of the chassis.
GE is a trademark of the General Electric Company. Manufactured under trademark license.
. . . . . . . . .3
. . . . . . . . . . . . . . 4
. . . . . . . . . . .7
. . . . . . . . . . . . . . . 8
. . . . . . 17
OWNER'S MANUAL &
INSTALLATION
INSTRUCTIONS
Cool Only Models
AKCQ08A
AKCQ10A
AKCQ10D
AKCQ12A
AKCQ12D
AKCQ14D
Heat/Cool Models
AKEQ10D
AKEQ12D
AKEQ14D
ESPAÑOL
For a Spanish version of this
manual, visit our Website at
www.GEAppliances.com.
Para consultar una version
en español de este manual
de instrucciones, visite nuestro
sitio de internet
www.GEAppliances.com.
FRANÇAIS
For a French version of this
manual, visit our Website at
www.GEAppliances.ca.
Pour un version français de
ce manuel d'utilisation, veuillez
visiter notre site web à l'adresse
www.GEAppliances.ca.
49-5000444 Rev. 0 01-20 GEA

Advertisement

loading
Need help?

Need help?

Do you have a question about the AKCQ10D and is the answer not in the manual?

Questions and answers

Summary of Contents for GE AKCQ10D

  • Page 1: Table Of Contents

    You can find the this information visiter notre site web à l’adresse on a label attached to the right www.GEAppliances.ca. side of the chassis. GE is a trademark of the General Electric Company. Manufactured under trademark license. 49-5000444 Rev. 0 01-20 GEA...
  • Page 2 THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME. Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family. We take pride in the craftsmanship, innovation and design that goes into every GE Appliances product, and we think you will too.
  • Page 3: Safety Information

    IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE For your safety, the information in this manual must be followed to minimize the risk of WARNING fire, electric shock or personal injury. ■ Use this appliance only for its intended purpose as described in this Owner’s Manual.
  • Page 4: Using The Air Conditioner

    Using the Air Conditioner - Controls Appearance may vary. Temp/Timer Air Conditioner Controls Lights above the touch pads on the air conditioner control panel indicate the selected settings. 1. POWER 6. Timer Turns air conditioner on and off. ON - Use to set the air conditioner to automatically turn ON from .5 to 24 hours later.
  • Page 5: Check Filter

    Using the Air Conditioner - Features To Adjust Fan Speeds Press the Fan Speed button to select the FAN Speed For some models, the fan speed can not be adjusted in four steps - Auto, Low, Med, or High. Each time the under HEAT mode.
  • Page 6: Additional Features

    Using the Air Conditioner - Features Additional Features The “Cool” circuit has an automatic 3 minute delayed The control will maintain the set temperature within 1°F start if the unit is turned off and on quickly. This prevents between 62°F and 86°F in cool or heat mode (on some overheating of the compressor and possible circuit models).
  • Page 7: Care And Cleaning

    • If they are clogged with dirt or soot, they may need to should be checked regularly. be professionally cleaned, a service available through GE Appliances service or other service companies. How to Insert the Batteries in the Remote Control 1. Remove the battery cover by rotating it to the unlock NOTES: position.
  • Page 8: Installation Instructions

    Installation Instructions For more help, visit GEAppliances.com IMPORTANT NOTE BEFORE YOU BEGIN For optimal energy efficiency and performance, we Read these instructions completely and carefully. recommend using the RAB24 Wall Sleeve and the supplied stamped aluminum outdoor grille or the IMPORTANT –...
  • Page 9 Installation of new grille provided with unit. ■ Wall sleeve must be securely fastened in wall before installing air conditioner. Drive more nails or 1. Remove the existing grille. (Exception: GE 26”.) AVANT ARRIÈRE screws through sleeve, into wall, if needed.
  • Page 10 Installation Instructions Emerson (15” Deep) Fedders (19-3/4” Deep) 1. Remove existing rear grille as shown on page 9 of 1. Remove existing rear grille as shown on page 9 of this manual and replace with provided louvered rear this manual and replace with provided louvered rear panel.
  • Page 11 Installation Instructions Fedders or Friedrich (16-3/4” Deep) GE/Hotpoint (16-7/8” Deep) 1. Retain existing rear grille. 1. Remove existing rear grille as shown on page 9 of this manual and replace with provided louvered rear 2. Using needle nose pliers, change the outdoor grille panel.
  • Page 12 Installation Instructions Sears or Carrier 51S Series Whirlpool (17-1/8” Deep) (18-5/8” Deep) 1. Remove existing rear grille as shown on page 9 of this manual and replace with provided louvered rear panel. 1. Remove existing rear grille as shown on page 9 of NOTE: You may need to drill holes in flange of existing this manual and replace with provided louvered rear sleeve to match new rear grille.
  • Page 13 Installation Instructions Whirlpool (23” Deep) Whirlpool (23” Deep) continued 17. Remove the plastic washer from the screw. 18. Screw and attach the other end of the ground wire to the unit. Make sure that the toothed washer is against the cabinet. 19.
  • Page 14 Installation Instructions White-Westinghouse/Frigidaire/Carrier White-Westinghouse or Frigidaire (22” Deep) 52F Series (16” + 17-1/2” Deep) 1. Remove existing rear grille as shown on page 9 of this manual and replace with provided louvered rear panel. 1. Remove existing rear grille as shown on page 9 of NOTE: You may need to drill holes in flange of existing this manual and replace with provided louvered rear sleeve to match new rear grille.
  • Page 15: Direct Unit Mounting

    Installation Instructions Direct Unit Mounting: The previous directions are the preferable way to mount the new rear grille. The units performance is slightly better and the possibility of drafts is reduced. As a last resort, direct mounting of the grille to the unit can be considered.
  • Page 16 Installation Instructions Trim Kit Installation Instructions Security Brackets Installation (It is important to install these brackets ■ Install the 1” x 1-1/2” x 84” long stuffer seal between the wall sleeve and the unit. A flat-bladed to prevent the chassis from being screwdriver or putty knife is recommended.
  • Page 17: Troubleshooting Tips

    Troubleshooting Tips... Before you call for service Problem Solution Air conditioner does Wall plug disconnected. Push plug firmly into wall outlet. not start House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker. Plug current device tripped.
  • Page 18 Notes 49-5000444 Rev. 0...
  • Page 19: Warranty

    This limited warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA. If the product is located in an area where service by a GE Appliances Authorized Servicer is not available, you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service.
  • Page 20: Consumer Support

    Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! You can also shop for more great GE Appliances products and take advantage of all our on-line support services designed for your convenience.