Summary of Contents for Mountfield AZURO INVERCORE CP Series
Page 1
INVERTER HEAT PUMP for pool water heating AZURO INVERCORE CP series WITH WIFI MODULE Operating and maintenance instructions 3BTE0594 / 3EXX0722 / 3EXX0723 / 3EXX0724 EN-01/2024-No.: 877-A...
CONTENTS 1. Introduction 1.1 Using the heat pump 1.2 How the heat pump works 1.3 Checking the packaging 2. Safety instructions 3. Description of the system and technical specifications 3.1 Technical data 3.2 Pool water parameters 3.3 Dimensions of the heat pump 3.4 Description of the main parts 3.5 Circuit board connection diagram 3.6 General plan of the cooling circuit...
1. INTRODUCTION We would like to thank you for choosing our heat pump. The heat pump is manufactured to strict standards to ensure quality and reliability for our customers. This operating manual contains all the information necessary for the installation, commissioning and maintenance of the system.
2. SAFETY INSTRUCTIONS CAUTION: Before first use, read this instruction manual. CAUTION: Before installing, read this instruction manual. CAUTION: Read these operating instructions before servicing or repairing. CAUTION: DANGER. Contains flammable gas. CAUTION: The device contains live electrical components. The device may only be opened by a person with appropriate electrical engineering qualifications.
(n) Assembly, connection to the power grid and commissioning must be carried out by a qualified person. (o) When connecting the pump to a socket (power supply), ensure that the phase, working and ground cables are laid correctly. (p) It is essential that the temperature of the swimming pool is kept below the value recommended by the swimming pool manufacturer.
3.3 Dimensions of the heat pump Note: The dimensions are given in millimetres. 3.4 Description of the main parts 1 – Fan protection grille (air outlet) 2 – Front Cover 3 – Top Cover 4 – Control panel 5 – Refrigerant pressure gauge 6 –...
3.6 General plan of the cooling circuit The heat pump is reversible so the pool can be heated or cooled: Pool water heating operation: The cool and liquid refrigerant absorbs the heat contained in the air via the evaporator (hot cooler) in which it evaporates;...
Page 9
Pool water cooling operation: A 4-way valve reverses the direction of coolant flow. The liquid evaporates in the heat exchanger (condenser) while heat is removed from the water; in the gaseous state, the liquid passes through the compressor, which heats it by compression and sends it to the evaporator, where it gives off heat to the surrounding air and returns to the liquid state;...
3.7 Safety and control systems The heat pumps are equipped with the following protection systems as standard: 3.7.1 Water flow switch With this flow switch, the heat pump only works when the filter pump is running (and water is circulating). This system prevents the heat pump from only heating the water in the heat pump itself. The protection also switches off the heat pump if water circulation is interrupted or reduced.
4. Installation and connection of the heat pump 4.1 Selection of location The heat pump is intended for outdoor installation and will work in virtually any outdoor environment as long as the following three conditions are met: 1. Fresh air - 2. Electricity connection - 3. Piping with pool filtering Do not install the pump in an enclosed area with restricted air access where air cannot circulate adequately.
4.2 Installing the heat pump The heat pump must be used in conjunction with a filter system that is part of the user's swimming pool installation. The flow rate through the heat pump should correspond to the recommended value (see table in chapter 3.1 Technical data) and can be up to 2 times higher. For correct use of the heat pump, a bypass consisting of three taps must be installed to regulate the flow of the heat pump (see chapter 6.2 Adjusting the water flow and pressure in the cooling circuit).
4.3 Electrical connection 4.3.1 Socket connection IMPORTANT: The heat pump comes with a power cord without a plug. The installation of the plug and socket must comply with the requirements of the IEC 60364 standard, including appropriate protection and the use of a residual current circuit breaker with a tripping current of up to 30 mA.
5. Control unit 5.1 Function of the control unit with LCD display COOLING Mode POWER Mode AUTO Mode SMART Mode HEATING Mode SILENT Mode Water Inlet Temp. WiFi-Symbol Press MODE Press this button to button to choose choose (Silent / mode Smart / Power) Press to turn on...
5.3 Application of the control unit 5.3.1 Changing the operating mode: Pressing the button changes the operating mode: Heating – Cooling – Auto. 5.3.2 Changing performance mode: By pressing the button the performance mode is changed. 5.3.3 Setting the target temperature: When the device is turned on, press the up button or down button to open the temperature...
Page 16
5.3.5 Time setting: o Press the down button for 5 seconds to open the time setting interface. The hours and minutes flash. Press the button to set the hour. The hour flashes. Pressing the up button or down button changes the value. Press the button again to set the minutes.
Page 17
5.3.8 Restore factory settings (only when power is off): Press the buttons for 5 seconds to restore factory settings. Press the buttons for 3 seconds to clear the error log. 5.3.9 Condition of the system: o Press the button for 3 seconds to enter the current state checking interface. To check a parameter, press the Up or Down button Code...
(for Android). Note: The WiFi module may not be included with the product. Information on this can be found in the product specification. Note: Instructions for using the app can be downloaded from the product website at www.mountfield. - 16-...
6. Application and operation of the system 6.1 Operating instructions IMPORTANT: In order for the heat pump to heat the swimming pool, the filter pump must be in operation and the water must flow through the heat exchanger. Never switch on the heat pump if there is no water and the filter system is not in ...
6.3 Water condensation The lower evaporator temperature during heat pump operation causes air moisture to condense on the evaporator fins and form condensation or frost. If the relative humidity is very high, this can lead to several liters of condensation per hour. The water runs down the fins into the bottom of the housing and drains through a plastic connector designed to connect to a 3/4"...
6.6 Information on operating the heat pump The efficiency of the heat pump increases as the room air temperature increases. It may take several days to reach the desired temperature. This time is completely normal and depends mainly on the climatic conditions, the volume of water in the pool, the size of the water surface, the operating time of the heat pump and the heat loss from the pool (e.g.
6.7 Simplified operating scheme External system Heat pump Task or heat pump control Display response button Insert the plug of the supply cable into the socket; If there is a permanent connection, Switching on the The water inlet switch on the circuit power supply to the temperature is breaker for the...
7. MAINTENANCE AND INSPECTION 7.1 Maintenance CAUTION: The device contains live electrical components. The device may only be opened by a person with appropriate electrical engineering qualifications. Risk of electric shock. IMPORTANT: Before carrying out any work on the device, make sure that it is disconnected from the power supply.
(oxidation, corrosion, flooding, etc.). Repairs during the warranty period may only be carried out by authorized workshops or the manufacturer's service workshop. The service and spare parts are provided by Mountfield as through its sales outlets and service centers. 7.4 Error messages Explanation of error messages caused by control component errors or safety operations.
Page 25
Code Problem Cause Solution Insufficient water flow Check water pump Have the pressure switch Pressure switch out of order High pressure error replaced Have the pump checked by a Cooling gas high pressure service technician Have the pump checked by a Insufficient refrigerant service technician Low pressure error...