Following T series electronic balance, manufactured by G&G GmbH, JJ series of electronic
balance is new generation with more high precision. In addition to all the advantages of T series, it
has following characteristics:
1.1 More high precision, hypersensitivity.
1.2 With auto calibration
1.3 Unit conversion feature: changing between g, ct, ozt
1.4 Balance is targeting output data interface and can be connected directly to the printer and
computer to collect and analyze the data. Balance can even be remote controlled by computer.
1.5 With counting function
In general, with high precision, high stability, high reliability and high efficiency, the "G&G"
electronic balances has widely replace the traditional mechanical, tray balances. The "G&G"
electronic balances have been widely used in all callings, in different kinds of measurement and
test. Those have played an important role in improving products quality, cost-effectiveness and
efficiency.
2. 2. 2. Specifications
Specifications
Specifications and
Depending on the difference of range and resolution, JJ series electronic scales are classified to 10
types as shown
JJ100
Model
110g
Capacity
Resolution Ratio 0.01g
10d
Calibration
Graduation
110g
Tare Scope
100g
Calibrating
Weight
Dimension
of
Platform
Volume
Power Supply
Use Temperature
Use Humidity
P.S.
JJ100-JJ1000
3. 3. 3. Operational
Operational
Operational Method
3.1 Turn on the power. Open the switch. The displaying windows displays from "F----1"to "F----
9" and after stabilizing for a certain time, "0·0" appears; Then preheats for 15 minutes.
Instability of the displaying at every beginning is normal; after a certain time, the displaying
Manual
for JJ JJ JJ Series
for
Manual for
JJ100, , , JJ200
JJ100
JJ100
JJ200
JJ200, , , JJ300
JJ300, , , JJ500
JJ300
and
Performance
and Performance
Performance indexes
:
JJ200 JJ300 JJ500 JJ600 JJ1000
200g
300g
500g
0.01g 0.01g 0.01g 0.01g
10d
10d
10d
200g
300g
500g
200g
200g
500g
135mm
196 (W) 215 (D) 62 (H) mm
AC 230V
is targeted windscreen and calibration weights
Method
Method
Series of of of Electronic
Series
Electronic
Electronic High
JJ500, , , JJ600
JJ500
JJ600
JJ600, , , JJ1000
JJ1000, , , JJ2000
JJ1000
indexes
indexes
600g
1000g
0.01g
10d
10d
600g
1000g
500g
1000g
50Hz/60Hz
3W
0-40C
 80 R.H
High
Precision
High Precision
Precision Balances
JJ2000, , , JJ3000
JJ2000
JJ3000
JJ3000, , , JJ5000
JJ2000
JJ3000
JJ5000
2000g
3000g
5000g
0.1g
0.1g
0.1g
10d
10d
2000g
3000g
5000g
2000g
2000g
5000g
190160mm
Balances
Balances
JJ5000, , , JJ6000
JJ5000
JJ6000
JJ6000
) ) )
JJ6000
6000g
0.1g
10d
10d
6000g
5000g

Advertisement

loading
Need help?

Need help?

Do you have a question about the JJ Series and is the answer not in the manual?

Questions and answers

Summary of Contents for G&G JJ Series

  • Page 1 2. 2. 2. Specifications Specifications Performance indexes Specifications and and Performance Performance indexes indexes Depending on the difference of range and resolution, JJ series electronic scales are classified to 10 types as shown JJ100 JJ200 JJ300 JJ500 JJ600 JJ1000 JJ2000 JJ3000 JJ5000 JJ6000...
  • Page 2 will stabilize. 3.2 In case of empty scale platform, the displaying deviates from zero, pressing “TARE” key, then the displaying will return to zero. 3.3 If the scale has not been used for a long time or just bought, the scale should be calibrated. Firstly, the scale is fully preheated (over 15 min.) with empty scale platform.
  • Page 3 3.7.3 Data format: starting data symbol ending enter 2unit 7units 3unit 1 unit 1 unit 3.7.4 Calibration: no calibration 3.7.5 Output pins content (9-core socket): 2 pins: RXD 3 pins: TXD 5pins: GND 3.7.6 Computer can control balance though RS232. The orders to balance are: 1BH+70H: sending data 1BH+71H: calibration (like “CAL”) 1BH+72H: counting...
  • Page 4 (1) Displaying window ( 2) UNIT (3) CAL (4) TARE (5) COUNT (6) ON/OFF Switch (7) Scale pan (8) Power (9) Fuse (10) Data output (11) Level indicate P.S. From JJ100 to JJ1000 is targeted windscreen and test weights. The installation of windscreen, see follows: From JJ2000 to JJ6000 there is no windscreen.
  • Page 5 5. 5. 5. Cautions Cautions operation Cautions for for operation operation 5.1 Using environment: indoor, max. Altitude: 2000m, temperature: 0-40℃, humidity ≤80%, Power fluctuations less than ±10% 5.2 The electronic scale is a precision instrument which needs to be gently handled during the weighing of articles.
  • Page 6 There will be a slight charge for We have the right to try to replace the defective product at least twice. the repair service of those products, by which the warranty period expires. Defective goods may only be returned to us by the customer with our express approval and at the customer's cost and risk. The notification of the defect does not release the customer from his obligation to pay.

This manual is also suitable for:

Jj100Jj200Jj300Jj500Jj600Jj1000 ... Show all