Beijer Electronics GN-9587 User Manual

Network adapter module, profinet network adapter mrp, fsu

Advertisement

Quick Links

User Manual
GN-9587 Network Adapter Module
PROFINET network adapter MRP, FSU
Doc ID: 171610
2025-02-20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GN-9587 and is the answer not in the manual?

Questions and answers

Summary of Contents for Beijer Electronics GN-9587

  • Page 1 User Manual GN-9587 Network Adapter Module PROFINET network adapter MRP, FSU Doc ID: 171610 2025-02-20...
  • Page 2 The information in this document is subject to change without notice and is provided as available at the time of printing. Beijer Electronics AB reserves the right to change any information without updating this publication. Beijer Electronics AB assumes no responsibility for any errors that may appear in this document.
  • Page 3: Table Of Contents

    12.4. Adapter Information Special Register (0x1100, 4352) ........35 12.5. Expansion Slot Information Special Register (0x2000, 8192) ......36 12.6. MODBUS Reference Documents .............. 38 12.7. MODBUS Tools ................... 38 13. Parameters ....................39 13.1. PROFINET IO Characteristics ..............39 Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 5: About This Manual

    About This Manual 1. About This Manual This manual contains information on the software and hardware features of the Beijer Electronics GN-9587 Network Adapter Module. It provides in-depth specifications, guidance on installation, setup, and usage of the product. 1.1. Symbols Used in This Manual This publication includes Warning, Caution, Note and Important icons where appropriate, to point out safety-related, or other important information.
  • Page 6: Safety

    Before using this product, please read this manual and other relevant manuals carefully. Pay full attention to safety instructions! In no event will Beijer Electronics be responsible or liable for damages resulting from the use of this product. The images, examples and diagrams in this manual are included for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Beijer Electronics cannot take responsibility or liability for actual use based on the examples and diagrams.
  • Page 7: About The G-Series System

    IP, EtherCAT, PROFINET, CC-Link IE Field, PROFIBUS, CANopen, DeviceNet, CC-Link, MODBUS/Serial etc. • Expansion Module - Expansion module types: Digital IO, Analog IO, and Special modules. • Messaging - The system uses two types of messaging: Service messaging and IO messaging. Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 8: Io Process Data Mapping

    Valid parameter data depends on the modules in use. For example, analog modules have settings of either 0-20 mA or 4-20 mA, and temperature modules have settings such as PT100, PT200, and PT500. The documentation for each module provides a description of the parameter data. 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 9: Specifications

    Refer to the IO module specification for specific details. Max. current field Max. DC 10 A power contact Wiring IO cable max. 2.0 mm (AWG 14) Weight 177 g Dimensions 54 mm x 99 mm x 70 mm Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 10: Communication Specification

    Via master device software Serial port RS232 for MODBUS/RTU, touch panel Serial configuration (RS232) Node: 1 (fixed) Baud rate: 115200 (fixed) Data bit: 8 (fixed) Parity bit: No parity (fixed) Stop bit: 1 (fixed) 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 11 • System power status - Green 2 LEDs (RJ45 connector): • Link/Active - Yellow • Not used - Green Module location Starter module, left side of the G-Series system Field power detection About 14 VDC Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 12: Wiring Diagram

    System power, 24 V System Power, ground Frame ground Frame ground Field power, ground Field power, ground Field power, 24 V Field power, 24 V WARNING Never connect system power to field power! Use separate power supplies. 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 13: Led Indicator

    Communication Green Normal communication. Communication ready Flashing Link Connection. green Communication error ASIC chip error. 6.3. ERROR (Error State) Status LED is Indication No error No error. Connection error Communication connection error. ASIC chip error. Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 14: Ios (G-Bus Status)

    • Mismatch vendor code between adapter and expansion module. 6.5. Field Power / System Power Status Indication No field / system power Not supplied 24 VDC field power. Supplied field, system Green Supplied 24 VDC field power. power 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 15: Socket

    RJ-45 Socket 7. RJ-45 Socket For information on network installation, refer to chapter Network Installation. RJ-45 Signal name Description Transmit + Transmit - Receive + Receive - Case Shield Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 16: Dip Switch

    • The device name must not start with numbers. Device names are assigned to PROFINET IO device when the device is being set up and placed in operation for the first time ("commissioned"). The default name is “GN9587-address”. 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 17 Dip Switch Setting the decimal value 63: 63(dec) = 0011 1111(bin) Dip switch 1 = LSB OFF = 0, ON = 1. Dip switches are set to: 1111 110X XX Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 18: Rs232 Port

    RS232 Port 9. RS232 Port Configuration interface used for the communication with IO Guide Pro or for firmware download. Pin no. Signal name Description Reserved RS232 TXD RS232 RXD RS232 GND 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 19: Hardware Setup

    Installation position is valid vertical and horizontal. The drawings are illustrative and may be out of proportion. CAUTION NOT following the space requirements may result in damaging the product. Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 20: Mount Module To Din Rail

    • GT-5XXX • GT-7XXX GN-9XXX modules have three locking levers, one at the bottom and two on the side. For mounting instructions, refer to Mount GN-9XXX Module. Mount to DIN rail Dismount from DIN rail 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 21 10.2.2. Mount GN-9XXX Module To mount or dismount a network adapter or programmable IO module with the product name GN-9XXX, for example GN-9251 or GN-9371, see the following instructions: Mount to DIN rail Dismount from DIN rail Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 22: Mount Removable Terminal Block

    Hardware Setup 10.3. Mount Removable Terminal Block To mount or dismount a removable terminal block (RTB), see the instructions below. Mount a removable terminal block Dismount a removable terminal block 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 23: Connect Cables To Removable Terminal Block

    To connect/disconnect cables to/from the removable terminal block (RTB), see the instructions below. WARNING Always use the recommended supply voltage and frequency to prevent damage to the equipment and ensure optimal performance. Connect cable Disconnect cable Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 24: Supplying The Power

    • Supply voltage 24 VDC (recommended voltage level). WARNING System power and field power must be supplied separately, see image above. System power and field power from the same power source could damage the device severely! 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 25: Field Power And Data Pins

    If the total network distance exceeds 100 meters, it is necessary to incorporate at least one unmanaged switch to extend the network length. This remains applicable even when ethernet network cables are connected sequentially from one adapter to the next. Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 26 Hardware Setup 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 27: Io Process Image Map

    IO Process Data Mapping. 11.1. Mapping Data into Image Table 11.1.1. Discrete Input Module 4 point input module 8 point input module 16 point input module 32 point input module 11.1.2. Discrete Output Module 4 point output module Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 28: Analog Input Module

    IO Process Image Map 8 point output module 16 point output module 32 point output module 11.1.3. Analog Input Module 4 channel analog input module 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 29: Analog Output Module

    IO Process Image Map 8 channel analog input module 11.1.4. Analog Output Module 4 channel analog output module Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 30: Example Of Input Process Image (Input Register) Map

    Input image data depends on slot position and expansion slot data type. Input process image data is only ordered by expansion slot position . Slot configuration (example) Slot no. Module description PROFINET adapter 8-discrete input 16-discrete input 8-discrete input 16-discrete input 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 31 Read byte Analog input Ch1 high byte Read byte Analog input Ch2 low byte Read byte Analog input Ch2 high byte Read byte Analog input Ch3 low byte Read byte Analog input Ch3 high byte Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 32: Example Of Output Process Image (Output Register) Map

    Discrete output 16 Point low byte byte 4 Write Discrete output 16 Point high byte byte 5 Write Slot Analog output Ch0 low byte byte 6 Write Analog output Ch0 high byte byte 7 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 33 Analog output Ch1 high byte byte Write Analog output Ch2 low byte byte Write Analog output Ch2 high byte byte Write Analog output Ch3 low byte byte Write Analog output Ch3 high byte byte Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 34: Modbus Special Register Map

    String type consists of valid string length (first 1 word) and array of characters. 12.2. Other Time Special Register (0x1028, 4136) Address Access Type, Description Size 0x1028(41 Read 1 word IO update time, main loop time (1 us unit) 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 35: Adapter Ip/Mac Address Special Register (0X1050, 4176)

    First 1 word is the adapter’s number. If GN-9251, then 0x9251. 0x1110(4368) Read 1 word Number of expansion slot. 0x1113(4371) Read Up to 33 Expansion slot Module ID. words First 1 word is adapter’s module ID. Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 36: Expansion Slot Information Special Register (0X2000, 8192)

    Slot#16 0x21E0(8672)-0x21FF(8703) Slot#17 0x2200(8704)-0x221F(8735) Slot#18 0x2220(8736)-0x223F(8767) Slot#19 0x2240(8768)-0x225F(8799) Slot#20 0x2260(8800)-0x227F(8831) Slot#21 0x2280(8832)-0x229F(8863) Slot#22 0x22A0(8864)-0x22BF(8895) Slot#23 0x22C0(8896)-0x22DF(8927) Slot#24 0x22E0(8928)-0x22FF(8959) Slot#25 0x2300(8960)-0x231F(8991) Slot#26 0x2320(8992)-0x233F(9023) Slot#27 0x2340(9024)-0x235F(9055) Slot#28 0x2360(9056)-0x237F(9087) Slot#29 0x2380(9088)-0x239F(9119) Slot#30 0x23A0(9120)-0x23BF(9151) Slot#31 0x23C0(9152)-0x23DF(9183) Slot#32 0x23E0(9184)-0x23FF(9215) 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 37 Input bit start address of input image bit this slot. + 0x07(+7) ** Read 1 word Output bit start address of output image bit this slot. + 0x08(+8) ** Read 1 word Size of input bit this slot. Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 38: Modbus Reference Documents

    * After the system is reset, the new “Set Value” action is applied. ** Nothing of output, input, and memory or configuration parameter corresponding slot returns Exception 02. 12.6. MODBUS Reference Documents http://www.modbus.org 12.7. MODBUS Tools http://www.modbustools.com - modbus poll http://www.win-tech.com - modscan32 2025-02 Beijer Electronics, Doc ID: 171610...
  • Page 39: Parameters

    DNS compliant name GN9587-address Supports extended assignment of IP address Fixed in slots Instance field of the object UUID Supports multiple write Requires IOPS/IOCS Requires engineering tool which supports at V2.25 least GSDML version Beijer Electronics, Doc ID: 171610 2025-02...
  • Page 40 1 2 4 8 16 32 64 128 256 512 Port 1: Port 1 Sub-module ident number 0x0003 Sub-slot number 32769 (0x8001) MAU type 100BASETXFD Port 2: Port 2 Sub-module ident number 0x0003 Sub-slot number 32770 (0x8002) MAU type 100BASETXFD 2025-02 Beijer Electronics, Doc ID: 171610...

Table of Contents