Page 1
USER'S MANUAL Split Air Conditioner ALASKA SENSEI SAC-U09SKWA/I SENSEI SAC-U12SKWA/I SENSEI SAC-U18SKWA/I SENSEI SAC-U24SKWA/I Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the User's Manual, please contact the local agent or visit www.sensei-europe.com...
Precautions Please read this operating manual carefully before operating the unit. material objects for reference. To realize the function of the air conditioner unit, a special refrigerant circulates in the system. good thermodynamic features which lead to a really high energy efficiency. The units WARNING: Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.
Page 4
Precautions WARNING Operation and Maintenance Do not connect air conditioner to multi-purpose socket. shock. or malfunction. repair air conditioner.
Page 5
Precautions WARNING than metal. Attachment unit.
Page 6
Precautions WARNING related to electricity and safety. Fuse of indoor unit:T3.15A 250V AC or T5A 250V AC,please refer to the screen printing on the circuit board for the actual parameters.which must be consistent with the parameters on the screen printing. For 9K-12K models,fuse of outdoor unit:T15A 250V AC or T20A 250V AC.
Page 7
Precautions WARNING yourself. installed in the line. for safety purpose. Qualification requirement for installation and maintenance man All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative organization and the qualification for dealing with the refrigeration system recognized by this industry.
Page 8
Precautions WARNING Indoor side DB/WB(°C Outdoor side DB/WB( °C 48/26 NOTE: The operating temperature range (from outside) for cooling is -15°C ~48°C; The heating operating temperature range for the electric heating belt model is -25°C ~24°C. The heating operating temperature range for models with an electronic expansion valve is -30°C ~24°C.
Page 9
Precautions WARNING Presence of fire extinguisher If any hot work is to be conducted on the refrigerating equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area. No ignition sources No person carrying out work in relation to a refrigerating system which involves exposing any pipe work shall use any sources of ignition in such a manner that it may lead to the risk of...
Page 10
Precautions WARNING Initial safety checks shall include: Repairs to sealed components ical ly t shall in su flamma Repair to intrinsically safe components itance that y the Cabling Detection of flammable refrigerants med a...
Page 11
Precautions WARNING Leak detection fluids are also suitable for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pipe-work. If a leak is suspected, all naked flames shall be removed/extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak.
Page 13
Precautions WARNING When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery cylinders are employed. Ensure that the correct number of cylinders for holding the total system charge is available. All cylinders to be used are designated for the recovered refrigerant and labelled for that refrigerant (i.e.
Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still can't be Phenomenon Check items Solution Power failure? Wait until power recovery. Is plug loose? Circuit break trips off or fuse is burnt out? break or fuse.
Page 16
system recognized by this industry. If it needs other technician to maintain and repair the manufacturer. Installation notes The minimum room area is shown on the nameplate or following table 1. 4.Leak test is a must after installation. 14.5 41.5 45.4 49.4 Minimum room area window mounted...
Page 17
Welding If you should cut or weld the refrigerant system pipes in the process of maintaining, please 1. Shut down the unit and cut power supply. 5. Cutting or welding. The refrigerant should be recycled into the specialized storage tank. well-ventilated.
Installation prepare Installation drawing Drainage pipe Tools 1 Level meter 4 Drill head 9 Leakage detector 11 Pressure meter 14 Measuring tape Installing the unit in the following places maycause malfunction. If it is unavoidable, please objects spread in the air. 4.
Page 19
Installation prepare Outdoor unit neighborhood. directly to sunlight or strong wind. 5. Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the fence for safety purpose. 1. Must follow the electric safety regulations when installing the unit. break.
Page 20
Installation prepare specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. purposes. 4. The appliance must be positioned so that the plug is accessible. within reach after installation. break should be included magnet buckle and heating buckle function, it can protect the Circuit break capacity of Power Cable (mm 、...
Page 21
Installation prepare — If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury. — If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause pressure rise or compressor rupture, resulting in injury.
Installation of outdoor unit Select it according to the actual installation situation 1. Select installation location according to the house structure. Note: outdoor unit. of the unit weight. Step 2: Install drain joint and chasis rubber plug 1. Connect the outdoor drain joint into the hole on the chassis, as shown in the picture below.
Page 23
Installation of outdoor unit Step 4: Connect indoor and outdoor pipe outdoor unit and then remove the handle. the pipe joint at the bellmouth of pipe. gas valve handle by referring to the sheet below. pipe joint 45~55 union nut Step 5: Connect indoor and outdoor pipe N(1) yellow-...
Page 24
Installation of outdoor unit Step 6: Neaten the pipes 1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min.semidiameter of must set a U-shaped curve in the pipe before pipe wall goes into the room, in order to prevent rain from getting into the room.
Check after installation The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? capacity. It may cause condensation and water dripping. Is water drained well? It may cause condensation and water dripping. Is the voltage of power supply according to the voltage marked on the It may cause malfunction or damaging the parts.
Page 26
1. Standard length of connection pipe Cooling capacity Cooling capacity connection pipe connection pipe pipe you should add 5ml of refrigerant oil for each additional 5m of connection pipe. as shown in the table. The additional refrigerant charging amount per meter is different Diameter of connection pipe Indoor unit throttle Outdoor unit throttle Cooling only,...
Page 27
A: Cut the pipe distance of indoor unit and outdoor unit. hard pipe mold pipe cutter pipe leaning uneven burr Note: the burrs from getting into the pipe. pipe downwards shaper F: Inspection again according to the steps above. smooth surface D: Put on the union nut connection pipe and outdoor valve;...
Page 29
PODR CZNIK U YTKOWNIKA Klimatyzator typu split ALASKA SENSEI SAC-U09SKWA/I SENSEI SAC-U12SKWA/I SENSEI SAC-U18SKWA/I SENSEI SAC-U24SKWA/I www.sensei-europe.com info@sensei-europe.com...
Page 32
fizycznych, sensorycznych lub przez dzieci bez nadzoru. matyzatora. W przeciwnym przez producenta, jego przedstawiciela serwisowego lub podobnie lub uszkodzenia. Nie naprawiaj klimatyzatora samodzielnie. b uszkodzenia.
Page 33
Nie wylewaj wody na pilota zdalnego sterowania, w przeciwnym razie wykwalifikowanymi specjalistami w celu naprawy. • • • • Klimatyzator wydziela zapach spalenizny. • specjalistów. uszkodzenia. odpowiedni obwód zasilania i przerywacz obwodu. spowodowa okablowania.
Page 34
em instalacji. przez producenta, jego przedstawiciela serwisowego lub podobnie sitodruku. W przypadku modeli 9K- 250 V AC lub T20A 250 V AC. V AC lub T25A 250 V AC.
Page 36
OSTRZE ENIE rodki ostro no ci Stro a DB/WB(°C Stro a z DB/WB(°C Ma ymal 48/ 6 Ma ymal UWAGA: OSTRZE ENIE Ni stoso a przyspi sza cyc proc s rozmra a ia l czyszcz ia i zal c prz z pr l y prz c pomi szcz z stal...
Page 51
Instalacja jednostki zew trznej Krok 4: P z rur wewn trzn i zewn trzn pra ym uc st i za r t za oru i yc lo a m uc z cz ruro i lic rur r p y u 4 Do r cz c lucz m...
Page 52
Instalacja jednostki zew trznej Krok 6: Uporz uj rury Rury l y popro y rozs i miar mo li o ci sc a Mi i cia rury to st a z u si cia i i m rury o pomi szcz ia al y usta i u zta ci lit ry U a y zapo i c prz...
Page 53
Sprawd po instalacji Spra i szymi ym iami po za iu i stalac Elementy do sprawdzenia Mo liwa usterka Czy urz i zosta o soli i mo si lu mito a zai stalo t st szcz l i czy to po ystarcza c y a o ia (o rz...
Page 54
Konfiguracja rury przy zeniowej rury przy cz • m m 8m Mi imal a rury przy cz W przy u urz ia z st rur przy cz m i ma ra icz co o mi imal ci rury przy cz Dla urz ia z rur przy cz...
Page 55
Metoda rozszerzania rur rozsz rz i rur st przyczy yci u czy i a c Rozsz rz rur z st pu cymi ro ami A: Przeci E: Rozszerz port Pot i r rur z Rozsz rz port za pomo st i st i Przyt rur za pomoc o ci a a...
Page 57
Дякуємо за вибір нашої продукції. Для належної експлуатації уважно прочитайте та зберігайте цю інструкцію. Якщо ви загубили Інструкцію Користувача, будь ласка, зв’яжіться з місцевим постачальником продукції або відвідайте сайт www.sensei-europe.com чи надішліть запит на адресу info@sensei-europe.com, щоб отримати електронну версію інструкції.
Need help?
Do you have a question about the ALASKA SAC-U09SKWA/I and is the answer not in the manual?