SwitchBot Meter Pro Manual
Also See for Meter Pro:

Advertisement

SwitchBot Meter Pro Manual

Package Contents

List of Components

List of Components

Liquid-crystal Display (LCD)

Liquid-crystal Display (LCD)

Preparation

You will need:

  • A smartphone or tablet using Bluetooth 4.2 or later.
  • The latest version of our app, downloadable via the Apple App Store or Google Play Store.
  • A SwitchBot account, you can register via our app or sign in to your account directly if you already have one.

Please note: if you intend to use the Cloud Service feature, you will need a SwitchBot Hub (sold separately).

apps.apple.com

play.google.com

iOS and Android system requirements:
https://support.switch-bot.com/hc/en-us/articles/12567397397271

Installation

  1. Power on
    Remove the battery insulation tab to power on your product.
  2. Add to the SwitchBot app
    Open our app, tap the "+" icon in the right-hand corner of the home page, and select Add Device. Find the device icon and select. Then follow the instructions to add Meter Pro.

Precautions

  • The Bluetooth signal transmission of this product may be affected by obstacles. In an open space without any obstacles, the maximum connectivity distance is 120 m (131 yd.).
  • When using a Meter Pro (CO2 Monitor) with an Indoor/Outdoor Meter together, it's recommended to add a SwitchBot Hub Mini or Hub 2 to sync the data from your Indoor/Outdoor Meter to eliminate connectivity range issues that may occur.
  • Prolonged exposure to conditions outside recommended ranges (5 ºC to 60 ºC, 20% to 80% relative humidity) may accelerate product aging.

CO2 Level

Color Green Yellow Red
Value Range 400-1000 1000-1400 1400+
Level Good Average Poor

When running on battery power, press the top button to speed up the data update.

Weather Forecast Icons

Clear Cloudy Drizzle Rainy
Overcast Light snow Snow

Battery Replacement

This device supports power supply from both a power cord and batteries. For CO2 Monitor calibration, battery power is recommended.
Open the battery cover, remove old batteries, and insert 2 new AA batteries, ensuring correct polarity. Then, close the battery cover.

Resetting Factory Settings

Press and hold the top button for 15 seconds.

Firmware Upgrades

In order to improve user experience, we will regularly release firmware updates to introduce new functions and solve any software defects that may occur during usage. When a new firmware version is available, we will send an upgrade notification to your account via our app. When upgrading, please make sure your product has sufficient battery or stay powered on and make sure your smartphone is within range to prevent interference.

Functions

Please scan the QR code to get detailed function description.

Frequently Asked Questions

What do I do when my product doesn't work properly?

  1. Ensure the battery isolation tab has been removed.
  2. Check if the batteries are installed with the correct polarity.
  3. Verify that the batteries have sufficient power or the power cord is properly connected.

My temperature and humidity readings are inaccurate, what can I do to fix this?
Recalibrate your Meter Pro (CO2 Monitor) via our app. If the issue persists, please contact Customer Support.

I can't connect my Meter Pro (CO2 Monitor) to my Indoor/ Outdoor Meter, what should I do?

  1. Check whether the distance between them exceeds the maximum Bluetooth connection range 120 m (131 yd.).
  2. Use a SwitchBot Hub device as a bridge between them.

What do I do when the CO2 Monitor's readings are inaccurate?
Recalibrate the CO2 Monitor via our app. If the issue persists, please contact Customer Support.
Please visit our website or scan the QR code below for more information.

Specifications

Material: ABS
Size: 92 mm x 79 mm x 25 mm (3.6 in. x 3.1 in. x 0.98 in.)
Weight: 154 g (5.4 oz.) (with batteries)
Power: 2 x AA battery; 5 V 1 A adapter
Battery Life: 1 year (CO2 detection inverval: 30 mins)
CO2 Measurement Range: 400 to 9999 ppm
Temperature Measurement Range: -20 ºC to 80 ºC (-4 ºF to 176 ºF)
Humidity Measurement Range: 0 to 99% RH
Temperature Precision:
-20 ºC to 0 ºC(-4 ºF to 32 ºF) 1±0.4 ºC/0.7 ºF]
0 ºC to 65 ºC(32 ºF to 149 ºF) 1±0.2 ºC/0.4 ºF]
65 ºC to 80 ºC(149 ºF to 176 ºF) [±0.3 ºC/0.5 ºF]
Humidity Precision:
0 to 10% RH (±3% RH)
10 to 90% RH (±2% RH)
90 to 99% RH (±3% RH)
Connectivity: BLE 4.2 or above

Contact & Support

Feedback: If you have any concerns or problems when using our products, please send feedback via our app through the Profile > Help & Feedback page.
Setup and Troubleshooting: support.switch-bot.com
Support Email: support@switch-bot.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download SwitchBot Meter Pro Manual

Advertisement

Need help?

Need help?

Do you have a question about the Meter Pro and is the answer not in the manual?

Questions and answers