Air conditioner Installation manual AC***DNTDCG • Thank you for purchasing this Samsung air conditioner. • Before operating this unit, please read this manual carefully and retain it for future reference.
Contents Safety Information Installation Procedure Step 1 Checking and preparing accessories and tools Step 2 Choosing the installation location Step 3 Drilling a hole through the wall Step 4 Fixing the installation plate Step 5 Purging the unit Step 6 Cutting or flaring the pipes Step 7 Connecting the refrigerant pipe Step 8 Performing leak test Step 9 Wrapping the pipes with the insulation...
• This manual explains how to install an indoor unit Flammable gas with a split system with two Samsung units. The use of other types of units with different control systems may damage the units and invalidate the warranty. The...
DO NOT INSTALL it, and immediately report Samsung’s technical support if the unit produces smoke, the damage to the carrier or retailer (if the installer or if the power cable is hot or damaged or if the unit is very the authorized technician has collected the material noisy.
• If any gas or impurities, except R-32 refrigerant, come Install the circuit breaker. into the refrigerant pipe, a serious problem may occur • If the circuit breaker is not installed, electric shock or fire and it may cause injury. may occur.
Page 6
• Any auxiliary device installed must be approved by ignition be used upon detection of leakage. Samsung and must be suitable for operating with the The following checks shall be applied to installations and refrigerant marked on the label. maintenance operations.
Detection of flammable refrigerants Charging procedure • Electronic leak detectors shall be used to detect • Follow industry standard refrigerant charging best flammable refrigerants, but the sensitivity may not practices. be adequate or may need re-calibration. (Detection • Prior to recharging the system shall be pressure tested equipment shall be calibrated in a refrigerant-free area.) with oxygen free nitrogen gas.
Installation Procedure Step 1 Checking and preparing accessories Step 2 Choosing the installation location and tools Installation location requirements Accessories • There must be no obstacles near the air inlet and outlet. • Install the indoor unit on a ceiling that can support its weight. Accessories in the indoor unit package •...
Page 9
– m : Total refrigerant charge in the system Do not install the air conditioner in following places. – A : Minimum required floor area – Calculated in accordance with UL 60335-2-40 Annex GG • Place where there is mineral oil or arsenic acid. Resin parts flame and the accessories may drop or water •...
Installation Procedure Overview of installation location requirements CAUTION • If changing the pipe direction from left to right, do not drastically bent it but slowly turn it in the opposite 3.94 inch (100 mm) or direction as shown. Otherwise, the pipe may be damaged more (recommended) 4.92 inch (125 4.92 inch (125...
Step 4 Fixing the installation plate CAUTION You can install the indoor unit on a wall, window frame, or • If you fix the indoor unit on a gypsum board, use only gypsum board. specified anchor bolts on reference positions. Otherwise, the gypsum surrounding the joints may crumble over WARNING time and cause the screws to be loosened and stripped.
Installation Procedure Step 6 Cutting or flaring the pipes (Unit: inch (mm)) Make sure that you prepared the required tools. Outer Conventional flare tool Flare tool for R-32 (pipe cutter, reamer, flaring tool and pipe holder) diameter clutch type Clutch type Wing nut type If you want to shorten the pipe, cut it using a pipe cutter 0.04~0.06...
Step 7 Connecting the refrigerant pipe Refrigerant oil Connect the indoor and outdoor units using pipes with flared connections (not supplied). For the lines, use insulated, unwelded, degreased and deoxidized copper pipe (Cu DHP type to ISO 1337 or UNI EN 12735-1), Operating pressure depends on outdoor unit specifications.
Installation Procedure Step 8 Performing leak test Step 9 Wrapping the pipes with the insulation Leak test After checking for gas leaks in the system, insulate the pipe, hose and cables. Then place the indoor unit on the installation To identify potential gas leaks in the indoor unit, inspect the plate.
Step 10 Installing and connecting the drain • Inadequate installation may cause water leakage. hose • If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage the Install the drain hose. furniture or floors.
Installation Procedure Step 12 Optional: Changing the direction of Direction of the drained water the drain hose Change the direction only when it is necessary. Detach the rubber cap with the flyer. Screw hole Screw CAUTION Drain hose • Make sure that the indoor unit is in upright position when you pour water to check for leakage.
Page 17
Route the connection cord through the side of the indoor AC power, Communication : M4 screw Unit: inch (mm) unit and connect the cable to the terminals refer to the figure below. Route the other end of the cable to the outdoor unit through the ceiling &...
Step 14 Optional : Setting the Emergency Temperature Output (ETO) function Emergency Temperature Output (ETO) function CAUTION • In order to deploy the ETO function, the MIM-B14 or MIM-B14U, an external contact interface module, must be installed in each indoor unit. ‐...
Page 20
Installation Procedure [Main] [Sub] ETO operation specifications Main indoor unit ‐ Based on the external contact control settings, the main indoor unit decides whether to generate output when an error (indoor unit stop) occurs. ‐ Based on the ETO settings, the main indoor unit decides whether to generate output according to the temperature and time conditions.
3. Set SEG8 for the Install option (02 mode) to '8'. (Refer to "Setting an indoor unit installation option") NOTE • The External Floating switch is not sold separately by Samsung. • External Control (MIM-B14U) and External Floating switch cannot be connected simultaneously. Only either of them can be connected at a time.
Installation Procedure Step 16 Optional : LED Display indicator specifications when checking Wi-Fi Easy Setup and Wi-Fi status The wireless remote control can be used for Easy Setup, checking the internet connection status and connecting or disconnecting Wi-Fi. Easy Setup Check internet connection status Connect/Disconnect Wi-Fi Mode...
LED Indicator Status Indicators On/Off Timer Wi-Fi Console Remarks Measure AP entry Wi-Fi LED flashing (0.5 on / 0.5 off) Device Check Wi-Fi LED flashing (0.5 on / 0.5 off) Easy Device Registration Wi-Fi LED flashing (1.5 on / 0.5 off) Setup Connection success Wi-Fi LED turns on...
Installation Procedure Step 17 Setting the indoor unit addresses Make sure that you are entered to the mode for and the installation options setting options. You cannot set both indoor unit addresses and the installation options in a batch: set both of them respectively. 2 Digit Common steps for setting the addresses and options 10 point ( 2SEG per point )
Page 25
Take the steps presented in the following table: Steps Remote control display Set the SEG2 and SEG3 values: Set the SEG2 value by pressing the button repeatedly until the value you want to set appears on the remote control display. SEG2 Set the SEG3 value by pressing the button repeatedly until the value you...
Page 26
Installation Procedure Steps Remote control display Set the SEG6 and SEG8 values: Set the SEG6 value by pressing the button repeatedly until the value you want to set appears on the remote control display. SEG6 Set the SEG8 value by pressing the button repeatedly until the value you want to set appears on the remote control display.
Page 27
Steps Remote control display Set the SEG11 and SEG12 values: Set the SEG11 value by pressing the button repeatedly until the value you want to set appears on the remote control display. SEG11 Set the SEG12 value by pressing the button repeatedly until the value you want to set appears on the remote control display.
Page 28
Installation Procedure Steps Remote control display 13 Set the SEG16 and SEG17 values: Set the SEG16 value by pressing the button repeatedly until the value you want to set appears on the remote control display. SEG16 Set the SEG17 value by pressing the button repeatedly until the value you want to set appears on the remote control display.
Page 29
Steps Remote control display 17 Set the SEG21 and SEG22 values: Set the SEG21 value by pressing the button repeatedly until the value you want to set appears on the remote control display. SEG21 Set the SEG22 value by pressing the button repeatedly until the value you want to set appears on the remote control display.
Page 30
Installation Procedure Check whether the option values you have set are Reset remote control: button Down + correct by pressing the button repeatedly. button Down + Press for 10 seconds You can see the "SW Initialization" message. [SEG2, SEG3] [SEG4, SEG5] [SEG6, SEG8] [SEG9, SEG10] [SEG11, SEG12]...
Setting the indoor unit addresses Option No. for an indoor unit address: 0AXXXX-1XXXXX-2XXXXX-3XXXXX Before installing an indoor unit, be sure to set an address for the indoor unit by taking the following steps: Make sure that the power is supplied to the indoor unit. If the indoor unit is not plugged in, it must include a power supply. Set an address for each indoor unit using the remote control, according to your air conditioning system plan, by referring to the following table and by following the steps in Common steps for setting the addresses and options on page 24 •...
Installation Procedure Setting the installation options in a batch Installation option No. for an installation options: 02XXXX-1XXXXX-2XXXXX-3XXXXX 1 Make sure that the power is supplied to the indoor unit. If the indoor unit is not plugged in, it must include a power supply. Indoor Unit The panel(display ) should be connected to an indoor unit to receive option.
Page 33
Option SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Function Page Use of drain pump & Emergency Stop ²) Details Indication Details Drain pump Drain pump Emergency Stop 0 or 4 Disuse 1 or 5 Disuse 2 or 6 Use with 3min delay Reserved Reserved Reserved...
Page 34
Installation Procedure Option SEG19 SEG20 SEG21 SEG22 SEG23 SEG24 Heating setting Function Page Individual control with remote control ⁴⁾ compensation Indication Details Indication Details Indication Details 0, 1 Indoor1 Default Reserved Reserved Reserved Indoor2 Indication 3.6℉ and details (2℃) Indoor3 9℉...
SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Bit 0 : Allow Fan control in auto mode Page heater lock out Heat pump lock out Bit 1 : Onboarding Type (AP / BLE) Indication Details Indication Details Indication Details Indication Details Disuse Disuse Not allow AP Onboarding...
Troubleshooting Detection of errors If an error occurs during the operation, an LED flickers and the operation is stopped except the LED. If you re-operate the air conditioner, it operates normally at first, then detect an error again. LED Display on the receiver &...
Page 37
LED Display Abnormal condition Error code 1. COND mid sensor is detached E241 2. Refrigerant leakage (2nd detection) E554 3. Abnomally high temperature on Cond (2nd detection) E450 4. Low pressure s/w (2nd detection) E451 5. Abnomally high temperature on discharged air on outdoor unit E416 (2nd detection) 6.