Specifications - Minolta FLASH METER VI Instruction Manual

Hide thumbs Also See for FLASH METER VI:
Table of Contents

Advertisement

Specifications

Type
Hand-held exposure meter for measuring ambient
and flash light
Reception method
Incident-light and spot reflected-light readings
Receptors
Incident-light readings: Spherical Diffuser, Flat
Diffuser, Swivels 270°
Spot reflected-light: angle 1°
Receptor element
Silicon photocell
Measuring modes
AMBI mode: Ambient light
CORD mode: Flash light using a sync cord
NON CORD mode: Flash light without a sync cord
Measuring range
(ISO100)
Ambient light
Flash light
Measuring distance
1.3 m to infinity (∞) (for spot measurement)
Viewfinder
Single-lens reflect type with fixed focal point
Magnification: 1.2x
Viewing angle: 12° (vertical) x 17° (horizontal)
Dioptric adjustment range: -3.0 to +1.0
Repeatability
±0.1 EV
Calibration coefficient Incident-light readings: C=330 (Spherical Diffuser)
Spot reflected-light: K=14
E78
(for incident-light reading only)
Incident-light readings:
EV-2.0 to 19.9
Spot reflected-light: Ev2.0 to 24.5
Incident-light readings:
FNO. 1.0 to 128+0.9 stop
Spot reflected-light:
FNO. 2.8 to 128+0.9 stop
C=250 (Flat Diffuser)
Display range
Exposure: F1.0 to 128+0.9 stop
(0.1 stop increments)
EV: -17 to 40.9 (0.1 stop increments)
Shutter speed (ambient): 30 min. to 1/16000 sec.
(1, 1/2, 1/3 stop increments)
Shutter speed (flash): 30 min. to 1/1000 sec.
(1, 1/2, 1/3 stop increments)
Frame rate (Opening angle of 180°):
8, 12, 16, 18, 24, 25, 30, 32, 64, 128
ISO: 3 to 8000 (1/3 increments)
Exposure difference: -10 to +10
(0.1 stop increments)
Analog scale: FNO. 1.0 to 90
(1/2 stop increments)
Analyze scale: Flash light proportion 0 to 100%
(25% increments)
Other functions
Latitude display function, Light Ratio Analyze
function, Memory function (10 measured values),
S/A/H calculation, Brightness difference function,
Exposure correction function: -10 to +10 (0.1 stop
increments)
Others
Sync terminal
Power
One AA alkaline dry cell (LR-6/1.5 V)
Battery life
Approx. 30 hours: (Continuous operation for
ambient light/incident light measurement, with
alkaline dry cell)
Operating
-10°C to 50°C ( 14°F to 122°F)
temperature/humidity Relative humidity 85% max. [at 35°C (95°F)],
range
no condensation
Storage
-20°C to 55°C (-4°F to 131°F)
temperature/humidity Relative humidity 85% max. [at 35°C (95°F)],
range
no condensation
Dimensions
63 (W) x 175 (H) x 30 (D) mm
Weight
170 g (excluding battery)
Standard accessories Spherical Diffuser, strap, case
*Optional accessories Flat Diffuser, Sync. Cord III
Specifications and external appearances described herein are subject to
change without notice.
Specifications
E79

Hide quick links:

Advertisement

Table of Contents