Air Control 02 Installation Manual

Decentralized

Advertisement

Quick Links

Installation manual
EN
(Original instructions)
Heat recovery unit
decentralized

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 02 and is the answer not in the manual?

Questions and answers

Summary of Contents for Air Control 02

  • Page 1 Installation manual (Original instructions) Heat recovery unit decentralized...
  • Page 2 First of all, we would like to thank you for having decided to give your preference to one of our products. As you can see, you have made a winning choice as you have purchased a product that represents the state of the art in home air conditioning technology. By implementing the suggestions contained in this manual, thanks to the product you have purchased, you will be able to enjoy optimal environmental conditions without problems with the least investment in terms of energy.
  • Page 3: Table Of Contents

    INDEX General ... p. 5 1.1 About this manual ......... . p. 5 1.2 General warnings .
  • Page 4 8.2 Dimensions ........... p. 29...
  • Page 5: General

    GENERALITIES GENERAL INFORMATION 1.1 About this manual ► This manual has been designed with the aim of providing all the Actions required explanations for the correct management of the appliance. Expected responses following an action This instruction booklet is an integral part of the •...
  • Page 6: General Warnings

    GENERALITIES Contains general information and important warnings that Commissioning, Maintenance and Troubleshooting They are must be known before installing and using the appliance. addressed only and exclusively to the Technical Assistance Center. Product Introduction Contains specific warnings and useful information for commissioning and routine maintenance.
  • Page 7: Disposal

    GENERALITIES It is forbidden to open the doors to access the internal It is forbidden to dispose of packaging material or leave it parts of the appliance without first having set the main within the reach of children as it may be a potential source switch of the system to "off".
  • Page 8: Product Introduction

    PRODUCT INTRODUCTION PRODUCT INTRODUCTION 2.1 Identification The appliance can be identified by the technical plate: Technical plate Reports the technical and performance data of the appliance. 1� Technical plate Tampering with, removing or missing identification plates does not allow for the safe identification of the product through its serial number and therefore voids the warranty.
  • Page 9: External Components List

    PRODUCT INTRODUCTION 2.4 External components list Configuration A Telescopic air duct Filter Grill Aesthetic cover 2.5 Internal components list Configuration A Ceramic exchanger Fan cover Appliance body Pre-cut for external electrical connection Pre-cut for under-floor electrical connection...
  • Page 10: Compatible Accessories

    PRODUCT INTRODUCTION 2.6 Compatible accessories Code Description Standard filter FDR - G3 Replacement Filter AHRC0041 Replacement ceramic exchanger SCR1 - Replacement ceramic exchanger Dn 100 AHRC0052 SCR2 - Replacement ceramic exchanger Dn 160 AHRC0051 ISO kit + ISO preparation SCE112001 KIS1 - Hole preparation with insulated pipe Dn 100 SCE116001 KIS2 - Hole preparation with insulated pipe Dn 160...
  • Page 11 PRODUCT INTRODUCTION Code Description Mounting frame AHRC0061...
  • Page 12: Installation

    Installation INSTALLATION 3.1 Preliminary warnings For detailed product information, please refer to It is recommended to use only the specific components chapter 8 p. 28 . for installation provided. The use of other components may cause water leakage, electric shock or fire. Installation must be performed by the installer.
  • Page 13: Minimum Installation Distances

    Installation • the functionality of load-bearing elements is not compromised • environments with the presence of aggressive, explosive atmospheres or flammable fluids • solar radiation and proximity to heat sources • there are no obstacles to the free circulation of air through the holes (plants, leaves, etc.) Avoid installing the unit near the sea.
  • Page 14: Positioning

    Please check that: Mounting the unit General assembly diagram Telescopic air duct Aesthetic cover Appliance body Core drilling Ø 110 model 02, Ø 162 model 05 Ceramic exchanger Grill Coring Outer side Core drilling Ø 110 model 02, Ø 162 model 05...
  • Page 15 Installation ► To make the hole: maintain a downward tilt towards the outer side ► mark the position of the hole To avoid the spread of large quantities of dust and debris into ► use a drill the environment, it is recommended to couple the core drill with suction systems.
  • Page 16 Installation ► ► align it with the internal wall thread Insert the grid from the inside ► ► wait for the cement mortar or polyurethane foam to set push the grill until it comes out from the outside ► pull the cord to fit it into the air duct To reposition If the telescopic air duct is longer than the wall, it must the heat exchanger: be cut to the required length to ensure proper...
  • Page 17: Electrical Connections

    Installation 3.7 Electrical connections The appliance leaves the factory fully wired and only needs electrical panels. Fit covers over the cables. Incomplete to be connected to the power supply. connection of covers may cause overheating of terminals, electric shock or fire. Preliminary warnings Any replacement of the power cable must be carried out exclusively by authorised personnel and in compliance...
  • Page 18 Installation Access to the electrical panel Before carrying out any intervention, make sure that the Access to the electrical panel is permitted only to specialized electrical power is switched off. persons. To access connections: ► pull the cover towards you ►...
  • Page 19: Finishing

    Installation 3.8 Finishing After making the electrical connections: ► attach the unit cover to the appliance body...
  • Page 20: Remote Control

    Remote control REMOTE CONTROL 4.1 Interface Description Inserting the batteries The remote control has been designed to allow easy use even without special programming. To activate it, simply insert the batteries. Batteries are not included. Use AAA type batteries. Key functions Basic functions Advanced functions (installer-specific) On/Off button...
  • Page 21 Remote control General ignition Activation ► press the LED flashes in the color of the mode in use the unit turns on Deactivation ► press the led flashes 4 times in red color the unit turns off...
  • Page 22: Commissioning

    COMMISSIONING COMMISSIONING 5.1 Preliminary warnings The section is dedicated to the Technical Assistance Center. The customer must be present at the test of the functioning of The features of the Technical Assistance Center are the appliance and informed about the contents of the manual described in the chapter p.
  • Page 23: Brightness Sensor

    COMMISSIONING • Low threshold setting 150 Index:Indicated by a quick flash of the green LED • Average threshold setting 200 Index:Indicated by two quick flashes of the green LED • High threshold setting 250 Index:Indicated by three quick flashes of the green LED To set the relative humidity threshold ►...
  • Page 24: Shutdown For Long Periods

    COMMISSIONING Delivery of the plant • the basic functional characteristics of the appliance Once all checks and controls on the correct functioning of the system have been completed, the installer is required to explain to • instructions for use the user: •...
  • Page 25: Maintenance

    Maintenance MAINTENANCE Routine maintenance Annual operations • tightening of the screws, fans and electrical box, external panelling of the unit The annual maintenance plan includes the following operations and checks and must be carried out by the Technical Assistance Centre •...
  • Page 26: Cleaning The Heat Exchanger

    Maintenance Cleaning the heat exchanger Unit cover Heat exchanger 2� Appliance body To remove: ► remove the power supply to the unit ► Press the release points and pull the unit cover towards ► remove the screws from the appliance body ►...
  • Page 27: Troubleshooting

    ANOMALIES AND REMEDIES ANOMALIES AND REMEDIES Preliminary warnings If one of the following anomalies is found: ► contact an authorised Technical Assistance Centre or professionally qualified personnel • ventilation does not activate The interventions must be carried out by a qualified •...
  • Page 28: Technical Information

    TECHNICAL INFORMATION TECHNICAL INFORMATION Technical data Models Fan (UNI EN 13141-8) (1) Type DC Brushless Axial Speed number m³/h Nominal air flow rate m³/h Air flow in the cycle m³/h Air flow maximum speed m³/h Air flow rate medium speed m³/h Air flow minimum speed m³/h...
  • Page 29 TECHNICAL INFORMATION Dimensions Size 02 Max 540 Max Ø 107 Size 05 Max 540 Max Ø 160...

This manual is also suitable for:

05

Table of Contents