EPH TOUCH RDT-RF-TB Installation & Operation Manual

Mains powered rf thermostat

Advertisement

Quick Links

RDT-RF-TB
RDT-RF-TW
Mains Powered RF Thermostat
Installation & Operation Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TOUCH RDT-RF-TB and is the answer not in the manual?

Questions and answers

Summary of Contents for EPH TOUCH RDT-RF-TB

  • Page 1 RDT-RF-TB RDT-RF-TW Mains Powered RF Thermostat Installation & Operation Guide...
  • Page 2: Table Of Contents

    Table of contents Installation Instructions Factory Default Settings ati n LCD Display Buttons Wiring Mounting & Installation Operating Instructions On Off n ti n Adjusting the Target Temperature Locking the Keypad Menu P01 Connecting a RDT-RF-Touch...
  • Page 3 P02 Operating Mode ta t C nt On Off ti na nteg a P03 Setting High and Low Limits P04 Hysteresis P05 Calibrate P07 Setback Mode P08 AFS - Air / Floor Sensor P09 FHL - Floor High Limit P10 Backlight P11 PIN Lock P12 Resetting the Thermostat...
  • Page 4: Installation Instructions

    Mains Powered RF Thermostat Installation Instructions...
  • Page 5: Factory Default Settings

    Off Backlight: Auto Operating mode: Normal High and low Limits: H te e i 0 ˚C et a e at e 0˚C AFS - Air / Floor / Sensor: 01 Internal Air Sensor i it 2 ˚C EPH Controls Ltd.
  • Page 6: Specifications

    Specifications Power supply / Input: 230Vac Power consumption: <1W e at e ange ˚C ient te e at e ˚C Ambient admissible humidity: 5-95% RH Dimensions: 91 x 91 x 40mm Internal temperature sensor: NTC 100K Backlight: White IP rating: IP20 Pollution degree: H te e i...
  • Page 7: Lcd Display

    LCD Display Room Floor Displays when high temp temperature & low temperature Frost mode Current/Target temperature RF transmission Calling for Keypad locked heat Target temp Boost to O mode Setback mode is enabled EPH Controls Ltd.
  • Page 8: Buttons

    Buttons Menu button OK button Setpoint Standby Setpoint decrease button increase RDT-RF-Touch...
  • Page 9: Wiring

    Temp Limit Sensor Terminal Connections Live In Neutral In 1 & 2 External Temp Sensor 3 & 4 External High Limit Sensor Note: NTC10K Ferrule temperature sensor and NTC Housing can be bought separately as an accessory. EPH Controls Ltd.
  • Page 10: Mounting & Installation

    Mounting & Installation Caution! Installation and connection should only be carried out by a ƒ a i e a i e e e t i ian e i e taff a e ƒ permitted to open the thermostat. t e t e tat i e in a a n t e i e...
  • Page 11 7. e t e ea i ing t t e e e e ing t t e a ate an tig ten the screw on the bottom of the thermostat. EPH Controls Ltd.
  • Page 12 45 113...
  • Page 13: Operating Instructions

    Mains Powered RF Thermostat Operating Instructions...
  • Page 14: On/Off Function

    On / Off Function Press t t n t e t e tat On Off en O on the screen the thermostat and zone will be set to OFF. Note: If the zone is in the constant OFF mode and the ON/ OFF button is pressed, this will change the mode of the zone to constant ON.
  • Page 15: Locking The Keypad

    To unlock the thermostat, press and hold for 10 seconds. will disappear from the screen. The buttons are now enabled. Menu This menu allows the user to adjust additional functions. Press and hold for 5 seconds to access the menu. EPH Controls Ltd.
  • Page 16: P01 Connecting A Rdt-Rf-Touch

    P01 Connecting a RDT-RF-Touch to a UFH10-RF This function allows the user to connect a RDT-RF-Touch to a a R_7-RF programmer. To connect a RDT-RF-Touch to a UFH10-RF 1. On the UFH10-RF: Press , ‘P01 rF COn’ will appear on the screen. MENU , ‘RF CONNECT’...
  • Page 17 2, 3 & 4. 5. On the R_7-RF Press to return to the main screen when thermostat pairing is complete. Note: When pairing additional zones to an R_7-RF , ‘r02’, ‘r03’, ‘r04’ can appear on the thermostat screen. EPH Controls Ltd.
  • Page 18: P02 Operating Mode

    P02 Operating Mode (Normal / Delay Start / TPI) There are three settings for selection, Normal, Delay Start or TPI mode. The default setting is Normal. Press and hold for 5 seconds. ‘P01 & rF’ will appear on the screen. Press until ‘P02 &...
  • Page 19: A E

    When the temperature rises above the target temperature, will disappear, and the thermostat will cancel the demand for heat. ) On / Off Control Temp 22˚C Target Temperature 21˚C 20˚C 19˚C 18˚C 17˚C Time Minutes EPH Controls Ltd.
  • Page 20: E A Ta T C Nt On Off

    P02 Operating Mode continued Delay Start Control (On/Off) When in this mode the thermostat is delayed by a variable time depending on the current temperature, target temperature and also the fall in temperature from when the delay start has activated. nti t e t e tat a ti ate When activated the thermostat will allow the heating system time...
  • Page 21 2 in te t e iffe en e i e t en t e t e tat i switched on immediately. The time delay will change if the temperature drops from the original calculation. EPH Controls Ltd.
  • Page 22: I E Ti Na Nteg A E

    P02 Operating Mode continued Time Proportional Integral Mode (TPI) When the thermostat is in TPI mode and the temperature is rising in the zone and falls into the Proportional Bandwidth section, TPI ta t t affe t t e t e e ati n e t e tat i...
  • Page 23 TPI control. You can set this e at e 0 C in 0 1 C in e ent Graph (21.1): TPI Control Temp 22˚C 21˚C Target Temperature 20˚C Proportional Bandwidth 19˚C 18˚C 17˚C Time Minutes Heating On Heating Off EPH Controls Ltd.
  • Page 24 P02 Operating Mode continued Time Proportional Integral Mode (TPI) Once TPI mode is selected, ‘CYC’ and ‘06’ will appear on the screen. to select from 2, 3, 6 or 12. Press ‘P Band’ and ‘2.0’ will appear on the screen. to select from 1.5 to 3.0.
  • Page 25: P03 Setting High And Low Limits

    Press ‘LOW LIMIT’ will appear on the screen, the temperature will begin to select the low limit for the thermostat. Press Press to return to normal operation. ‘LIMIT’ will appear on the screen. EPH Controls Ltd.
  • Page 26: P04 Hysteresis

    P04 Hysteresis HOn 0.4°C HOFF 0°C This menu allows the installer to change the switching iffe entia t e t e en t e te e at e i i ing an falling. If ‘HOn i et at 0 ˚C an t e et int i 20˚C t en t e thermostat will switch on when the temperature drops below 19 ˚C...
  • Page 27: P05 Calibrate

    ‘P01 & rF’ will appear on the screen. Press until ‘P05 & CAL’ appears on the screen. Press to select. ‘CAL’ and the actual temperature will appear on the screen. Press to calibrate the temperature. Press Press to return to normal operation. EPH Controls Ltd.
  • Page 28: P07 Setback Mode

    P07 Setback Mode (0°C / Off) In Setback mode, the thermostat reduces the temperature 10 C e ete e a t etting i et t 0 C O an nee activated to function. Setback mode will only work when the zone i ti e ff...
  • Page 29: P08 Afs - Air / Floor Sensor

    04 Internal air sensor with an external hight limit sensor This option allows the user to record the room temperature with the internal sensor while having the external sensor record e at e t e ent e eating (NTC10K Ferrule temperature sensor required). EPH Controls Ltd.
  • Page 30 P08 AFS - Air / Floor Sensor continued 05 External air sensor with an external hight limit sensor This option allows the user to record the room temperature with external sensor 1 while having external sensor 2 record e at e t e ent e eating (NTC10K Ferrule temperature sensors required).
  • Page 31: P09 Fhl - Floor High Limit

    ‘P09 & FHL’ appears on the screen. Press to select. e ig i it te e at e i n t e to choose the desired high limit temperature. Press Press to return to normal operation. EPH Controls Ltd.
  • Page 32: P10 Backlight

    P10 Backlight AUTO There are three settings for selection. ‘AUt’ The backlight is on for 10 seconds when any button is pressed. ‘On’ The backlight is permanently on. ‘OFF’ ig t i anent ff Press and hold for 5 seconds. ‘P01 &...
  • Page 33: P11 Pin Lock

    PIN digit. When the last digit of the PIN is set, press It is necessary to verify the PIN, ‘vEr’ will appear on the screen Re enter the PIN code again. Press EPH Controls Ltd.
  • Page 34 P11 PIN Lock continued e i e an t e i a ti ate t e e i ati n i ente e in e t t e back to the menu. When the PIN lock is active, the will appear on the screen.
  • Page 35 2 Access PIN in the installer menu. Press , ‘ON’ will appear on the screen. Press select ‘OFF’. . ‘0000’ i Press n t e nte t e Press The PIN is now disabled. EPH Controls Ltd.
  • Page 36: P12 Resetting The Thermostat

    P12 Resetting the Thermostat To reset the thermostat to factory settings. Press and hold for 5 seconds. ‘P01 & rF’ will appear on the screen. Press until ‘P12 & rSt’ appears on the screen. Press to select. ‘NO n t e Press ‘YES n t e...
  • Page 37 Notes...
  • Page 38 Notes...
  • Page 39 Notes...
  • Page 40 EPH Controls IE EPH Controls UK technical@ephcontrols.co.uk technical@ephcontrols.com www.ephcontrols.co.uk/contact-us www.ephcontrols.com/contact-us +44 1933 322 072 +353 21 471 8440 Cork, T12 W665 Harrow, HA1 1BD...

This manual is also suitable for:

Touch rdt-rf-tw

Table of Contents