1 Introduction
This guide will walk through the installation of an iVAC Pro system step-by-step, with illustrations of DIP switch settings for each iVAC Pro product that is
included in an iVAC Pro System. This guide is showing the switch positions for a system with 8 tools or less.
2 Dust Collector Compatibility
Before starting to set up your iVAC Pro system, please verify that your dust collector is compatible with the iVAC Pro Switch you ordered. Please contact
iVAC technical support if you may have any question regarding the compatibility of your dust collector with iVAC Pro Switches at info@ivacswitch.com
3 Preparation
Please do not install your iVAC Pro Products to its physical location until the RF communication of connection sets are set up and tested properly as
described below.
Please unbox your iVAC Pro Products and put them on a work table with power bar so you can power up each connection set and test it.
4 Set up each connection set
Please follow the sequence below to set up each connection set in your iVAC Pro system
Connection Set
SWITCH
A
iVAC Pro System Installation Guide
Ver 1.0 16128-001
DIP Setting
Instructions
Set to System Address A (S1 = OFF, S2 = OFF)
Set Delay Time to 5 sec (S5 = OFF, S6 = OFF)
Test it manually - ON / OFF Dust Collector
Set Delay Time to your preference
Set Mode to Auto - Ready to work with other iVAC modules

Advertisement

loading
Need help?

Need help?

Do you have a question about the Pro and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IVAC Pro

  • Page 1 Please do not install your iVAC Pro Products to its physical location until the RF communication of connection sets are set up and tested properly as described below. Please unbox your iVAC Pro Products and put them on a work table with power bar so you can power up each connection set and test it. 4 Set up each connection set...
  • Page 2 Set Delay Time to 5sec (S3 = ON) Test it manually - Open / Close Gate A2 Set Delay Time to your preference Set Mode to Auto - Ready to work with other iVAC modules Set to System Address A (S1 = OFF, S2 = OFF) SENSOR...
  • Page 3 Set Delay Time to 5sec (S3 = ON) Test it manually - Open / Close Gate A4 Set Delay Time to your preference Set Mode to Auto - Ready to work with other iVAC modules Set to System Address A (S1 = OFF, S2 = OFF) SENSOR...
  • Page 4 Set Delay Time to 5sec (S3 = ON) Test it manually - Open / Close Gate A6 Set Delay Time to your preference Set Mode to Auto - Ready to work with other iVAC modules Set to System Address A (S1 = OFF, S2 = OFF) SENSOR...
  • Page 5 Set Delay Time to 5sec (S3 = ON) Test it manually - Open / Close Gate A8 Set Delay Time to your preference Set Mode to Auto - Ready to work with other iVAC modules Set to System Address A (S1 = OFF, S2 = OFF) SENSOR...
  • Page 6: Hardware Installation

    For Tool Plus / Tool Advantage Sensor: The Pro Tool Plus / Tool Advantage senses a magnetic field. It must be mounted 12" to 18" away from any source other than what you want to detect. This includes motors, transformers, power lines behind walls or other devices which produce magnetic fields. To test for interference, set the Pro Tool Plus to the OFF position and the power tool OFF.