Air-Conditioners Indoor unit PSA-M·KA Series English OPERATION MANUAL FOR USER Deutsch BEDIENUNGSHANDBUCH FÜR BENUTZER Français MANUEL D’UTILISATION POUR L’UTILISATEUR Nederlands BEDIENINGSHANDLEIDING VOOR DE GEBRUIKER Español MANUAL DE INSTRUCCIONES PARA EL USUARIO Italiano ISTRUZIONI DI FUNZIONAMENTO PER L’UTENTE Ελληνικά ΕΓΧΕΙΡΙΔΙΟ ΟΔΗΓΙΩΝ ΧΡΗΣΕΩΣ ΓΙΑ...
2006/66/EC Article 20 Information for end-users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of-life, should be disposed of separately from your household waste.
1. Safety Precautions Warning: • This unit should be installed in rooms which exceed the floor space • Do not pierce or burn. specified in outdoor unit installation manual. • Be aware that refrigerants may not contain an odour. Refer to outdoor unit installation manual. •...
2. Parts Names ■ Wired Remote Controller Controller interface The functions of the function buttons change depending on the screen. Refer to the button function guide that appears at the bottom of the LCD for the functions they serve on a given screen. When the system is centrally controlled, the button function guide that corresponds to the locked button will not appear.
Page 5
2. Parts Names Display The main display can be displayed in two different modes: “Full” and “Basic”. The factory setting is “Full”. To switch to the “Basic” mode, change the setting on the Main display setting. (Refer to operation manual included with remote controller.) <Full mode>...
3. Operation ■ About the operation method, refer to the operation manual that comes with each remote controller. 3.1. Turning ON/OFF [ON] [OFF] Press the [ON/OFF] button. Press the [ON/OFF] button again. The ON/OFF lamp will light up in green, The ON/OFF lamp will come off, and and the operation will start.
3. Operation 3.3. Temperature setting 3.5. Airflow direction setting <Cool, Dry, Heat, and Auto> <[Manual] To Change the Airflow’s Up/Down Direction> PSA-M•KA Series Hold both ends of the vanes and move them to the desired position. Nor- 28.5 Room Room mally, set the vanes to the horizontal or upward airflow direction for cool- Cool Set temp.
4. Function Setting Function selection of remote controller The setting of the following remote controller functions can be changed. Change the setting when needed. Depending on the function, an administrator password or maintenance password may be required at the time of setting. The default for the administrator password is “0000”, and “9999”...
Page 9
4. Function Setting Restrictions for the sub remote controller <Ventilation setting> Press the [F4] button to go through the ventilation setting options in the Main Main menu order of “Off,” “Low,” and “High.” * Settable only when Lossnay unit is Operation connected.
5. High Power Function description High-power operation function allows the units to operate at higher-than- normal capacity so that the room air can be conditioned to an optimum temperature quickly. This operation will last for up to 30 minutes, and the unit will return to the normal operation mode at the end of the 30 minutes or when the room temperature reaches the preset temperature, whichever is earlier.
6. Timer 6.1. For Wired Remote-controller Change the setting with the [F3] or Timer [F4] button. On/Off timer /Yes You can use Function Selection of remote controller to select which of 3 AM 12:50 • On/Off timer: No (disable)/Yes (en- types of timer to use: 1 On/Off timer, 2 Auto off timer, or 3 Weekly timer.
6. Timer 6.1.2 Auto off timer will appear on the Main display <Button operation> in the Full mode when the Auto-Off Room Bring up the Timer setting screen. timer is enabled. Timer Cool Set temp. Auto (Refer to page 10) On/Off timer On AM 12:50 OFF PM 2:30 appears when the timer is...
Page 13
6. Timer 6.3. OU silent mode The weekly timer setting screen will Weekly timer 1 appear and the current settings will Tue Wed Thu Fri Sat Sun Function description No.1 - - - - : - - - - - - - - °...
Page 14
6. Timer The setting screen will appear. The current settings will appear. Night setback OU silent mode Move the cursor to the desired item Night setback Temp. range 19°C - 28°C Start Stop Silent with the [F1] or [F2] button out of Press the [SELECT] button to go to Start 23:00...
7. Energy Saving 7.1. Restriction Change the settings with the [F3] or Temp. range 7.1.1 Setting the temperature range restriction Temp. range [F4] button. Cool •Dry 25°C - 28°C <Button operation> • Temp. range: No (unrestricted) or Heat 20°C - 25°C Auto 22°C - 28°C Yes (restricted)
Page 16
7. Energy Saving 7.2. Energy saving The screen to make the settings Restriction for the operation lock function will 7.2.1 Automatic return to the preset temperature Operation locked No /Yes Location Indiv. /Hotel appear. After the Auto return function is enabled, when the operation mode On/Off –/ Locked Mode...
Page 17
7. Energy Saving Change the settings with the [F3] or The screen to enable (Yes)/disable Auto return Energy saving [F4] button. (No) the energy-saving operation Auto return /Yes Cool: After Auto return: No (disable)/Yes schedule will appear. Energy saving /Yes back to 28°C Heat:...
Page 18
7. Energy Saving 7.3. Energy data [Monthly data/Daily data] Energy data Displays the energy consumption Energy data display (for unit time, month, and day) 2020 – 1 123456.7kWh 2019 – 12 123456.7kWh for the last 14-month period includ- Energy consumption per unit time (for one month) or per month/day (for 2019 –...
Page 19
7. Energy Saving Energy data reset Energy consumption data (per unit time, month, and day) are initialized. <Button operation> Select “Data reset” from the En- Energy data ergy data menu, and press the Unit time (1 month) Month/Day (14 months) [SELECT] button.
8. Initial Setting 8.1. Basic setting 8.1.2 Daylight saving time Function description 8.1.1 Clock The start/end time for daylight saving time can be set. The daylight <Button operation> saving time function will be activated based on the setting contents. Select “Initial setting” from the Main Main Main menu menu, and press the [SELECT]...
Page 21
8. Initial Setting 8.2. Display setting Move the cursor to the following Daylight saving time items with the [F1] button to make No / 8.2.1 Main display Day/ Week/ Month the settings. <Button operation> Date(Start) Sun / 5th / Mar Start time AM 1:00 Forward to...
Page 22
8. Initial Setting 8.2.4 Language selection Select “B&W inversion” with the Main display Function description [F1] or [F2] button, and select the Full /Basic The desired language can be set. The language options are English, display mode “Yes” or “No” with B&W inversion French, German, Spanish, Italian, Portuguese, Swedish, Russian, the [F3] or [F4] button, and press...
9. Service 9.1. Initialize remote controller 9.2. Remote controller information Function description Function description The remote controller can be initialized to the factory shipment state. The information of the remote controller in use can be checked. Note that the following data will be initialized. The remote controller will automatically be started up after being <Button operation>...
10. Maintenance 10.1. Error infomation Checking the error information While no errors are occurring, page Main Main menu When an error occurs, the following screen will appear 2/2 of the error information can be and the operation LED will blink. Check the error status, viewed from the menu operation.
11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) ■ Air conditioner does not heat or cool well. Clean the filter. (Airflow is reduced when the filter is dirty or clogged.) ■ Check the temperature adjustment and adjust the set temperature. ■...
11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) ■ Noise is louder than specifications. The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than the noise specification, which was measured in anechoic room.
Page 27
EC ДЕКЛАРАЦИЯ ЗА СЪОТВЕТСТВИЕ IZJAVA O SKLADNOSTI ES MITSUBISHI ELECTRIC AIR CONDITIONING SYSTEMS EUROPE LTD. TOKYO BUILDING, 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN hereby declares under its sole responsibility that the air conditioners and heat pumps described below for use in residential, commercial and light-industrial environments: erklärt hiermit auf seine alleinige Verantwortung, dass die Klimaanlagen und Wärmepumpen für das häusliche, kommerzielle und leicht-industrielle Umfeld wie unten beschrieben:...
Page 28
MITSUBISHI ELECTRIC, PSA-M71KA*, PSA-M100KA*, PSA-M125KA*, PSA-M140KA* Note: Its serial number is on the nameplate of the product.
Page 29
<ENGLISH> <PORTUGUÊS> English is original. The other languages versions are translation of the original. O idioma original é o inglês. As versões em outros idiomas são traduções do idioma original. CAUTION CUIDADO • Refrigerant leakage may cause suffocation. Provide ventilation in accordance with EN378-1. •...
Page 30
<POLSKI> <ROMÂNĂ> Językiem oryginału jest język angielski. Inne wersje językowe stanowią Textul original este în limba engleză. Versiunile pentru celelalte limbi sunt tradu- tłumaczenie oryginału. ceri ale originalului. UWAGA ATENŢIE • Wyciek czynnika chłodniczego może spowodować uduszenie. Należy zapewnić wentylację •...
Page 31
Travellers Lane, Hatfield, Herts., AL10 8XB, England, U.K. Polish Branch Krakowska 50, PL-32-083 Balice, Poland MITSUBISHI ELECTRIC TURKEY ELEKTRİK ÜRÜNLERI A.Ş. Şerifali Mah. Kale Sok. No: 41 34775 Ümraniye, İstanbul / Turkey MITSUBISHI ELECTRIC (RUSSIA) LLC 115114, Russia, Moscow, Letnikovskaya street 2, bld.1, 5th floor Please be sure to put the contact address/telephone number on this manual before handing it to the customer.