Vertiv RLS50 Description And Installation Manual
Vertiv RLS50 Description And Installation Manual

Vertiv RLS50 Description And Installation Manual

Self-strip block feed-thru half-tap activator kit

Advertisement

Quick Links

RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit
Description and Installation Manual (641-202-009), Revision E
Specification Number: 128701

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RLS50 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vertiv RLS50

  • Page 1 RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description and Installation Manual (641-202-009), Revision E Specification Number: 128701...
  • Page 2 NetXtend™ are trademarks of Vertiv Energy Systems, Inc. All other trademarks are the property of their respective owners. © 2017 Vertiv Energy Systems, Inc. All rights reserved. Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 3: Table Of Contents

    Reason for Reissue ............................... 7 Other Practices ................................. 7 Description ......................... 7 Installation ........................8 DC Power, Outdoor Enclosure & Service Contacts ........12 Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 4: Admonishments Used In This Document

    SAFETY! Informs the reader of general safety information, reminders, precautions, or policies not related to a particular source of hazard or to fire safety. (ISO, ANSI, OSHA) Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 5: Important Safety Instructions

    Wear eye protection. Use certified and well maintained insulated tools. Use double insulated tools appropriately rated for the work to be performed. Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 6: Personal Protective Equipment (Ppe)

    If necessary to repair equipment containing static sensitive components, wear an appropriately grounded wrist strap, work on a conductive surface, use a grounded soldering iron, and use grounded test equipment. Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 7: About This Document

    ABOUT THIS DOCUMENT Purpose This practice provides a description of the RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit, as well as installation instructions. Reason for Reissue This practice is being reissued to provide updated information. Other Practices Refer to other company and local practices for the correct methods, tools, and materials to be used in performing procedures not specifically described within this practice.
  • Page 8: Installation

    Use a tool, such as a screwdriver, to lift the activator (as shown in Figure 1). Cut the ends of the cross-connect wire pair (24/22AWG) evenly. ALERT! Do not strip the wire! Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 9 RLS block in the position where the Half-Tap will be inserted. Figure 3: Removing an Activator Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 10 (as shown in Figure 5). Terminate this pair in the normal manner as was done for the feeder termination Figure 5: Routing the Continuing Jumpers Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 11 Remove the jumper wire running from the second distribution termination and discard. If service interruption is possible, replace the Half-Tap activator with a standard one after dual distribution is no longer needed. Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 12: Dc Power, Outdoor Enclosure & Service Contacts

    Answers technical product and system questions; determines status of warranties and OSP.TAC@VertivCo.com contractual agreements for repair. Phone 1.800.800.5260 [1] Contact Account Management for custom configurations. [2] Contact Spare Parts for parts and accessories. Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 13 This page is intentionally blank. Vertiv | RLS50 Self-Strip Block Feed-Thru Half-Tap Activator Kit Description & Installation Manual (641-202-009) | Rev. E...
  • Page 14 VertivCo.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 641-202-009 (RE 10/17)

Table of Contents