Summary of Contents for HP ProLiant XL645d Gen10 Plus
Page 1
HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide Part Number: 10-150100-Q324 Published: May 2024 Edition: 4...
Page 2
HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide Abstract Abstract This document is for the person who installs, administers, and troubleshoots servers and storage systems. Hewlett Packard Enterprise assumes that you are qualified in the servicing of computer equipment, and trained in recognizing hazards in products with hazardous energy levels.
Table of contents Table of contents Illustrated parts catalog Server components Fan module spare parts Drive spare parts Drive blank spare parts SSD spare parts Hard drive spare parts Drive backplane spare parts Fan backplane spare parts Enclosure midplane spare parts HPE Smart Storage Battery spare part Power supply spare parts Power switch module spare parts...
Page 4
InfiniBand adapter spare parts NVMe adapter spare parts Front jumper spare parts Trusted Platform Module 2.0 Gen10 Plus spare part Customer self repair Removal and replacement procedures Safety considerations Preventing electrostatic discharge Symbols on equipment Server warnings and cautions Preparation procedures Power up the server Power down the server Extend the chassis from the rack...
Page 5
Removing and replacing the GPU interposer Removing and replacing the power backplane Removing and replacing the midplane interposer Removing and replacing a PCIe riser Removing and replacing the air baffle Removing and replacing an expansion board or a type -p storage controller Removing and replacing the OCP NIC 3.0 adapter Removing and replacing a DIMM Removing and replacing a heatsink...
Page 6
Rear panel LEDs and buttons System board module components System board components System maintenance switch descriptions DIMM slot locations DIMM label identification Processor and socket components Midplane interposer ports SXM4 GPU slots PCIe GPU tray components Riser board components Primary riser board components Secondary riser board components Power supply LED Fan module numbering...
Server components Server components Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported parts information, see the Hewlett Packard Enterprise PartSurfer website ( http://www.hpe.com/info/partssurfer http://www.hpe.com/info/partssurfer). HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Transceiver spare parts Transceiver spare parts SUV cable spare part SUV cable spare part Miscellaneous cable spare parts Miscellaneous cable spare parts Fan module spare parts Fan module spare parts HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
P20599-001 HPE 1.6TB NVMe MU SFF SC U.3 CD6 SSD P20790-001 HPE 1.92TB NVMe RI SC U.3 PM1733 SSD P20735-001 HPE 1.92TB NVMe RI SFF SC U.3 CM6 SSD P20760-001 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 11
HPE 400GB SAS MU SFF SC DS SSD P09922-001 HPE 800GB SAS MU SFF SC PM1645a SSD P20838-001 HPE 800GB SAS WI SFF SC PM5 SSD P06602-001 HPE 800GB SAS WI SFF SC SS540 SSD P22586-001 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 12
HPE 6.4TB SAS MU SFF SC PM1645a SSD P20841-001 HPE 6.4TB SAS MU SFF SC PM5 SSD P06583-001 HPE 6.4TB SAS MU SFF SC SS540 SSD P22584-001 HPE 6.4TB SAS MU SFF SC PM6 SSD P37174-001 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 13
HPE 1.92TB SATA MU SFF SC SE5031 SSD P13810-001 HPE 1.92TB SATA RI SFF SC MV SSD P18484-001 HPE 1.92TB SATA MU SFF SC MV SSD P19695-001 HPE 1.92TB SATA RI SFF SC PM883 SSD P05322-001 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
HPE 3.84TB SAS RI SFF SC MV SSD P49736-001 HPE 7.68TB SAS RI SFF SC MV SSD P49739-001 HPE 15.36TB SAS RI SFF DS SSD P49742-001 Hard drive spare parts Hard drive spare parts HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Fan backplane spare parts Customer self repair: Mandatory Mandatory Description Description Spare part number Spare part number Fan backplane P35445-001 Enclosure midplane spare parts Enclosure midplane spare parts Customer self repair: Optional Optional HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Used for power switch housing replacement - plastic and metal only. Discard the right angle cable as it is not required. Used for power switch, USB, and sensor replacement. Front panel pass-thru board spare parts Front panel pass-thru board spare parts Customer self repair: Optional Optional HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
HPE 100Gb QSFP28 MPO SR4 100 m transceiver 849443-001 HPE BLc VC 1G SFP SX transceiver 453577-001 SUV cable spare part SUV cable spare part Customer self repair: Mandatory Mandatory HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Spare part number Spare part number SUV cable P25583-001 Miscellaneous cable spare parts Miscellaneous cable spare parts Customer self repair: Mandatory Mandatory Table 1. Miscellaneous cable kits Table 1. Miscellaneous cable kits HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
GPU option components GPU option components Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported parts information, see the Hewlett Packard Enterprise PartSurfer website ( http://www.hpe.com/info/partssurfer http://www.hpe.com/info/partssurfer). HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
For more information, see Removal and replacement procedures. Subtopics Subtopics GPU spare parts GPU spare parts GPU tray spare parts GPU tray spare parts GPU interposer spare parts GPU interposer spare parts HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
System board module components Hewlett Packard Enterprise continually improves and changes product parts. For complete and current supported parts information, see the Hewlett Packard Enterprise PartSurfer website ( http://www.hpe.com/info/partssurfer http://www.hpe.com/info/partssurfer). HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Front jumper spare parts Trusted Platform Module 2.0 Gen10 Plus spare part Trusted Platform Module 2.0 Gen10 Plus spare part System board spare parts System board spare parts Customer self repair: Optional Optional HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
HPE Smart Array P408i-p SR Gen10 Controller 836269-001 HPE NS204i-t Gen10 Plus NVMe Boot Controller NS204i-t Gen10 Plus NVMe Boot Controller spare parts spare parts Customer self repair: Mandatory Mandatory HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Subtopics AMD EPYC 7xx2 processor spare parts AMD EPYC 7xx2 processor spare parts AMD EPYC 7xx2 processor spare parts AMD EPYC 7xx2 processor spare parts Customer self repair: Optional Optional HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 27
2.8 GHz, MILAN EPYC 7473X, 24 C, 2 W processor P46980-001 3.1 GHz, MILAN EPYC 7373X, 16 C, 2 W processor P46981-001 OCP NIC adapter spare parts OCP NIC adapter spare parts HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
HPE SN1610Q 32Gb 2p FC HBA P14420-001 HPE SN1100Q 16Gb 1p FC HBA 853010-001 HPE SN1100Q 16Gb 2p FC HBA 853011-001 Network adapter spare parts Network adapter spare parts Customer self repair: Mandatory Mandatory HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 29
Description Description Spare part number Spare part number HPE XL645d Gen10 Plus 12Gb NVMe 2p Adapter P42199-001 Front jumper spare parts Front jumper spare parts Customer self repair: Mandatory Mandatory HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Packard Enterprise vous l'envoie directement. Il existe deux catégories de pièces CSR : Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à Hewlett Packard Enterprise de Obligatoire— HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 31
Hewlett Packard Enterprise dovrà sostenere le spese di spedizione e di manodopera per il servizio. Customer Self Repair Customer Self Repair Hewlett Packard Enterprise Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 32
Para obtener más información acerca del programa de Reparaciones del propio cliente de Hewlett Packard Enterprise, póngase en contacto con su proveedor de servicios local. Servicio de garantía exclusivo de componentes Servicio de garantía exclusivo de componentes HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 33
Centro de suporte técnico da Hewlett Packard Enterprise para que um técnico o ajude por telefone. A Hewlett Packard Enterprise especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à Hewlett Packard HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 34
No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a Hewlett Packard Enterprise substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 35
HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 36
HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Removing and replacing a fan module Removing and replacing a fan backplane Removing and replacing a fan backplane Removing and replacing a drive blank Removing and replacing a drive blank HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
HPE Trusted Platform Module 2.0 Gen10 Plus option HPE Trusted Platform Module 2.0 Gen10 Plus option Safety considerations Safety considerations Before performing service procedures, review all the safety information. Subtopics Subtopics Preventing electrostatic discharge Preventing electrostatic discharge HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists. To reduce the risk of injury from a hot component, allow the surface to cool before touching. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Preparation procedures Preparation procedures Subtopics Subtopics Power up the server Power up the server Power down the server Power down the server HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Extend the chassis from the rack Extend the chassis from the rack Procedure Procedure Loosen the thumbscrews on either side of the chassis, and then extend the chassis from the rack. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 42
NOTE: For proper cooling, do not exceed two minutes with the chassis front door open. Exceeding two minutes can lead to thermal damage or system shutdown. Procedure Procedure Open the chassis front door. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 43
4. Remove the system board module from the chassis. The image shows removing a right system board module. The steps for removing the left system board module are the same. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 44
3. Disconnect all peripheral cables from the server. 4. Remove the system board module from the chassis. 5. Place the system board module on a flat, level work surface. 6. Remove the system board module access panel. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Remove the system board module from the chassis Remove the system board module from the chassis Remove the system board module access panel Remove the system board module access panel HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
2. Power down the server. 3. Remove the GPU tray from the chassis. The right GPU tray is shown in the image. The steps for removing the left GPU tray are the same. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Supported transceivers can be hot-swapped—removed and installed while the server is powered-on. However, to prevent potential damage to the transceiver or the fiber-optic cable, disconnect the cable from the transceiver before hot-swapping HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
If installing a hot-plug fan without powering down the system, the chassis front door must be closed within two minutes. Procedure Procedure 1. Open the chassis front door. 2. Remove the fan module. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 49
2. Power down the server. 3. Disconnect all peripheral cables from the server. 4. Remove the midplane panel. 5. Remove all the fans installed in the backplane. 6. Remove the fan backplane. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
CAUTION: To prevent improper cooling and thermal damage, do not operate the system unless all bays are populated with either a component or a blank. Remove the drive blank. Figure 1. HPE Apollo n2600 Gen10 Plus Chassis Figure 1. HPE Apollo n2600 Gen10 Plus Chassis HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Push the Power button. b. When the flashing stops and the icon on the button is no longer illuminated or flashing, press the drive handle release button to release the drive handle. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 52
Pull the release lever to disengage the drive from the backplane, and slide the drive out of the drive bay. 4. Prepare the replacement drive. 5. Install the drive. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 53
2. Extend the chassis from the rack . 3. Disconnect all peripheral cables from the server. 4. Remove the system board module from the chassis. 5. Remove the GPU tray. 6. Remove the power supplies. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 54
7. Remove the midplane panel. 8. Disconnect the display port cable. 9. Remove the enclosure midplane assembly. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 55
7. Disconnect all the cables from the front panel pass-thru board to the front panel and drive backplane. 8. To disengage the boards from the chassis, slide them towards the middle of the chassis. 9. Remove the required pass-thru board using the T-10 Torx screwdriver. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 56
2. Power down the server. 3. Open the chassis front door. 4. Disconnect the cables from the power switch module. 5. Remove the power switch module using the T-10 Torx screwdriver. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 57
4. Support the drive cage from the door end to keep the drive cage from sliding off. 5. Disconnect the drive data and power cables from the front panel pass-thru boards to the backplane. 6. Remove the backplane using the T-15 Torx screwdrivers. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 58
3. Disconnect all peripheral cables from the server. 4. Remove the GPU tray from the chassis. The right GPU tray is shown in the image. The steps for removing the left GPU tray are the same. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 59
7. Install all components removed from the failed GPU tray into the new GPU tray. 8. Install the GPU tray into the chassis. Depending on the chassis configuration, your GPU tray might look different. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 60
5. Place the GPU module on a safe surface and ensure that no damage occurs to the GPU module, heatsink, or FCI connector. Returning GPU: Returning GPU: 6. Install the FCI connector caps removed from the replacement GPU onto the FCI connectors of the defective GPU, if not already HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 61
Removing a coldplate and A100 SXM4 GPU Installing an A100 SXM4 GPU and coldplate Installing an A100 SXM4 GPU and coldplate Removing a coldplate and A100 SXM4 GPU Removing a coldplate and A100 SXM4 GPU HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 62
5. Apply new thermal pads to the GPU as seen in the original pad locations and represented as below. (Pads for the Apollo systems are contained within this spare kit). HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 63
About this task WARNING: WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. Procedure Procedure HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 64
9. Install the screws and bracket removed in the previous step onto the replacement GPU using the T-10 Torx screwdriver. The location of the bracket and the number of screws used will vary depending on GPU model. double-wide GPU HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 65
For more information, see GPU power cabling. 12. Connect all peripheral cables to the server. 13. Install the GPU tray. 14. Power up the server . Results Results To replace the component, reverse the removal procedure. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 66
5. Place the GPU tray on a flat, level work surface. 6. Remove the GPU bridge using a T-10 Torx screwdriver. Results Results To replace the component, reverse the removal procedure. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 67
6. Extend the chassis from the rack. 7. Remove the chassis midplane panel. 8. Remove power supply modules. 9. Open the enclosure midplane latches. 10. Remove the GPU interposer-power backplane assembly. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 68
Remove the GPU tray from the chassis Extending the chassis from the rack Extending the chassis from the rack Remove the midplane panel (675d Gen10 Plus) Remove the midplane panel (675d Gen10 Plus) HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 69
7. Extend the chassis from the rack. 8. Remove the chassis midplane panel. 9. Open the enclosure midplane latches. 10. Turn chassis upside-down and remove the GPU interposer-power backplane assembly. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 70
Remove the GPU tray from the chassis Removing and replacing a power supply Removing and replacing a power supply Extending the chassis from the rack Extending the chassis from the rack HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 71
Remove the system board module from the chassis Remove the system board module access panel Remove the system board module access panel Removing and replacing a PCIe riser Removing and replacing a PCIe riser HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 72
5. Place the system board module on a flat, level work surface. 6. Remove the system board module access panel. 7. Remove the midplane interposer, if removing the secondary or tertiary riser. 8. Remove the PCIe riser: Primary riser Secondary riser HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Remove the system board module access panel Removing and replacing the midplane interposer Removing and replacing the midplane interposer Removing and replacing the air baffle Removing and replacing the air baffle HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 74
2. Power down the server. 3. Disconnect all peripheral cables from the server. 4. Remove the system board module from the chassis. 5. Place the system board module on a flat, level work surface. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 75
3. Disconnect all peripheral cables from the server. 4. Remove the system board module from the chassis. 5. Place the system board module on a flat, level work surface. 6. Remove the system board module access panel. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
2. Power down the server. 3. Disconnect all peripheral cables from the server. 4. Remove the system board module from the chassis. 5. Place the system board module on a flat, level work surface. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Hewlett Packard Enterprise recommends Identifying the processor and socket components before performing this procedure. Procedure Procedure 1. Back up all server data. 2. Power down the server. 3. Disconnect all peripheral cables from the server. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 78
Allow the alcohol to evaporate before continuing. 11. Apply new thermal grease to the processor in the pattern shown in the following illustration. Use the full contents of the thermal grease syringe. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 79
Use a T-20 Torx screwdriver to tighten the captive screws in the sequence specified on the heatsink label. When using a torque wrench to tighten the screws, apply a torque of 1.58 N-m (14 lbf-in). HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
1. Observe the following alerts. CAUTION: To avoid damage to the processor or system board, only authorized personnel should attempt to replace or CAUTION: install the processor in this server. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 81
Use a T-20 Torx screwdriver to loosen the captive screws in the sequence specified on the heatsink label. b. Lift the heatsink away from the system board. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 82
Hold the lift tabs near the front end of the rail frame and pivot the rail frame to the closed position. A click sound indicates that the rail frame is properly engaged. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 83
When using a torque wrench to tighten the screws, apply a torque of 1.58 N-m (14 lbf-in). 16. Apply new thermal grease to the processor in the pattern shown in the following image. Use the full content of the thermal grease syringe. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 84
Use a T-20 Torx screwdriver to tighten the captive screws in the sequence specified on the heatsink label. When using a torque wrench to tighten the screws, apply a torque of 1.58 N-m (14 lbf-in). HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge. Procedure Procedure HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 86
Use a T-20 Torx screwdriver to loosen the captive screws in the sequence specified on the heatsink label. b. Lift the heatsink away from the system board. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 87
Installing the processor on the new system board 19. Use a T-20 Torx screwdriver to loosen the three captive screws in the sequence shown in the following image, and then pivot the force frame upward. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 88
Hold the lift tabs near the front end of the rail frame, and then pivot the rail frame to the closed position. A click sound indicates that the rail frame is properly engaged. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 89
Installing the heatsink on the new system board 23. Apply new thermal grease to the processor in the pattern shown in the following image. Use the full contents of the thermal grease syringe. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 90
Use a T-20 Torx screwdriver to tighten the captive screws in the sequence specified on the heatsink label. When using a torque wrench to tighten the screws, apply a torque of 1.58 N-m (14 lbf-in). HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Re-entering the server serial number and product ID About this task About this task After you replace the system board, the node serial number and the product ID must be configured: Procedure Procedure HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 92
4. Remove the system board module from the chassis. 5. Remove the system board module access panel. 6. Place the module on a flat, level work surface. 7. Remove the midplane interposer. 8. Remove the front jumper. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 93
3. Disconnect all peripheral cables from the server. 4. Remove the system board module (tray) from the chassis. 5. Place the system board module (tray) on a flat, level work surface. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 94
9. Remove the M.2 SSDs from the boot controller using the PH#0 screwdriver. a. Remove the M.2 SSD from drive bay 1. b. Turn over the boot controller. c. Remove the SSD from drive bay 2. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 95
2. Place the extension bracket on the boot controller stand (callout 1) and engage the attachment screw by hand (callout 2). NOTE: Top side of the bracket must face outward. NOTE: HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 96
4. Insert the M.2 drive at an angle into the connector on the boot controller (callout 1), then fix it to the bracket (callout 2) and engage the attachment screw by hand (callout 3). NOTE: Provide support for both the M.2 drive and extension bracket while engaging the attachment screw to prevent NOTE: damage to the components. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 97
SSD module and that both parts are aligned. 6. Secure the extender bracket to the standoff with the attachment screw. Tighten the screw firmly by taking care not to strip the threads HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 98
NOTE: System ROM and firmware messages might display "energy pack" in place of "Smart Storage Battery." Energy pack refers to both HPE Smart Storage batteries and HPE Smart Storage Hybrid capacitors. Procedure Procedure HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 99
6. Disconnect the storage controller backup power cable. 7. Remove the HPE Smart Storage Battery assembly from the system board module. 8. Remove the HPE Smart Storage Battery from the socket. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
6. Remove the system board module access panel. 7. Locate the battery on the system board. 8. Slightly push the metal tab, and then remove the system battery from the socket. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 101
Remove the system board module from the chassis Remove the system board module from the chassis Remove the system board module access panel Remove the system board module access panel HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
IML messages and associated troubleshooting information to resolve critical and cautionary IML events. To access troubleshooting resources for your product, see the Hewlett Packard Enterprise website Hewlett Packard Enterprise website . Diagnostic tools Diagnostic tools Subtopics Subtopics Product QuickSpecs Product QuickSpecs HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Secure Boot is a server security feature that is implemented in the BIOS and does not require special hardware. Secure Boot ensures that each component launched during the boot process is digitally signed and that the signature is validated against a set of trusted certificates HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
3. If an administrator password is set, enter it at the prompt and press Enter. The Shell> prompt appears. 4. Enter the commands required to complete your task. 5. Enter the exit command to exit the Shell. Intelligent Provisioning Intelligent Provisioning HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
For ProLiant servers, firmware is updated using the Intelligent Provisioning Firmware Update utility. Do not update firmware if the version you are currently running is required for compatibility. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Hewlett Packard Enterprise Gen10 and Gen10 Plus servers support all USB operating speeds depending on the device that is connected to the server. Subtopics Subtopics External USB functionality External USB functionality HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Power switch module Drive box 1 (labeled Node 2) chassis front door lever button Drive box 2 (labeled Node 1) Front panel LEDs and buttons Front panel LEDs and buttons HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
When all four LEDs described in this table flash simultaneously, a power fault has occurred. For more information, see Front panel LED power fault codes. Subtopics Subtopics UID button functionality UID button functionality Front panel LED power fault codes Front panel LED power fault codes UID button functionality UID button functionality HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Power supply 10 flashes PCIe expansion cards installed in riser board 11 flashes Chassis 12 flashes GPU card 13 flashes Front panel pass-thru board components Front panel pass-thru board components HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Front panel pass-thru board 1 (Node 1 drive I/O) Front panel pass-thru board 2 (Node 2 drive I/O) Rear panel components Rear panel components SXM GPU configuration SXM GPU configuration HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 112
Slot 10 PCIe4 x16 (16, 8, 4, 2, 1) SUV port Slot 9 PCIe4 x16 (16, 8, 4, 2, 1) OCP 3.0 NIC adapter slot blank Serial number/iLO information pull tab HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
If the Health LED indicates a degraded or critical state, review the system IML or use iLO to review the system health status. System board module components System board module components HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
The system board module consists of a system board and a midplane interposer. Subtopics Subtopics System board components System board components Midplane interposer ports Midplane interposer ports System board components System board components HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
System maintenance switch descriptions DIMM slot locations DIMM slot locations DIMM label identification DIMM label identification Processor and socket components Processor and socket components System maintenance switch descriptions System maintenance switch descriptions HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
DIMM slots are numbered sequentially (1 through 8) for each processor. The supported AMP modes use the letter assignments for population guidelines. The arrow indicates the front of the server. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
To determine DIMM characteristics, see the label attached to the DIMM. The information in this section helps you to use the label to locate specific information about the DIMM. For more information about product features, specifications, options, configurations, and compatibility, see the HPE DDR4 SmartMemory QuickSpecs: https://www.hpe.com/support/DDR4SmartMemoryQS https://www.hpe.com/support/DDR4SmartMemoryQS HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
L = LRDIMM (load reduced) The maximum memory speed and capacity is a function of the memory type, memory configuration, and processor model. Processor and socket components Processor and socket components HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 119
Item Item Description Description Pin field Rail frame Carrier frame Processor Force frame Captive screws (Torx T-20) Midplane interposer ports Midplane interposer ports HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 120
Item Item Description Description Port 1 Port 2 SXM4 GPU slots SXM4 GPU slots HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 121
PCIe GPUs or 8 single-wide PCIe GPUs in a PCIe GPU tray. 8 single-width GPU configuration 8 single-width GPU configuration Item Item Description Description PCIe single-width GPU slots 1-8 4 double-width GPU configuration 4 double-width GPU configuration HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Pump-cold plate signal connector for processor Storage controller backup power connector Slot 10 PCIe4 ×16 (16, 8, 4, 2, 1) Slim SAS x4 port for front panel LEDs Power supply LED Power supply LED HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Nonredundant Mode. If the missing fan is installed, the system will begin functioning in Redundant Mode. If more than one fan is missing during power up, the user will be allowed to boot, but will be using an unsupported configuration. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Pull the open handle to remove a drive. Close the handle to fully seat and lock a drive into place. Handle release button Releases the drive handle for removal and insertion. Drive bay numbering Drive bay numbering HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 127
For component and LED identification, see the user guide for your storage controller series on the Hewlett Packard Enterprise website (https://www.hpe.com/info/smartstorage-docs https://www.hpe.com/info/smartstorage-docs). For a complete list of supported storage controller models, see the server QuickSpecs on the Hewlett Packard Enterprise website (https://www.hpe.com/info/qs https://www.hpe.com/info/qs). NVMe adapter components NVMe adapter components HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 128
Item Description Description Drive retaining screws Thumbscrew Thermal interface pad Drive bay 1 Drive bay 2 HPE 2280 M.2 30mm extender bracket components HPE 2280 M.2 30mm extender bracket components HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
HPE Smart Storage Battery cabling HPE Smart Storage Battery cabling Power switch cabling Power switch cabling Drive backplane power cabling Drive backplane power cabling GPU power cabling GPU power cabling Cabling guidelines Cabling guidelines HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 130
Grip the body of the cable connector. Do not pull on the cable itself because this action can damage the internal wires of the cable or the pins on the port. If a cable does not disconnect easily, check for any release latch that must be pressed to disconnect the cable. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Remove cables that are no longer being used. Retaining them inside the system can restrict airflow. If you intend to use the removed cables later, label and store them for future use. Front I/O cabling Front I/O cabling HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 132
Front I/O Secondary Riser to System Board Storage Interposer x4 Slim SAS to x4 Slim SAS cable routing Front I/O, Front Panel Pass-Thru Board to Front Panel x4 Slim SAS cable routing Display port cabling Display port cabling HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
8 embedded SATA configuration cabling for chassis 1 8 embedded SATA configuration cabling for chassis 1 8 embedded SATA configuration cabling for chassis 2 8 embedded SATA configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 134
SAS/SATA backplane port 2 P28453-001 Half width MB port 1 MB storage interposer Red dots (callout 2) 8 embedded SATA configuration cabling for chassis 2 8 embedded SATA configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 135
Half width MB port 1 MB storage interposer Red dots (callout 2) 8 SAS/SATA (Smart Array) configuration cabling for chassis 1 8 SAS/SATA (Smart Array) configuration cabling for chassis 1 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 136
Red line and dots (callout 2) P408i-p/E208i-p port 2 8 + 8 embedded SATA configuration cabling 8 + 8 embedded SATA configuration cabling Supports up to 8 SFF drives per system board module. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 137
(2x) x4 Mini SAS cable routing 8 + 8 SAS/SATA with E208i-p/P408i-p controller configuration cabling 8 + 8 SAS/SATA with E208i-p/P408i-p controller configuration cabling Supports up to 8 SFF SAS/SATA drives per system board module. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 138
8 NVMe configuration cabling for chassis 2 2 embedded SATA + 2 NVMe drive configuration cabling for chassis 1 2 embedded SATA + 2 NVMe drive configuration cabling for chassis 1 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 139
MB storage interposer Red dots (callout 4) 2 embedded SATA + 2 NVMe drive configuration cabling for chassis 2 2 embedded SATA + 2 NVMe drive configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 140
Half width MB port 1 MB storage interposer Red dots (callout 4) 2 embedded SATA + 6 NVMe configuration cabling for chassis 1 2 embedded SATA + 6 NVMe configuration cabling for chassis 1 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 141
HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 142
MB storage interposer port 2 Pink line and dot (callout 5) 2 embedded SATA + 6 NVMe configuration cabling for chassis 2 2 embedded SATA + 6 NVMe configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 143
2 embedded SATA + 6 NVMe configuration cabling for chassis 2 2 embedded SATA + 6 NVMe configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 144
MB storage interposer port 2 Pink line and dot (callout 5) 2 SAS/SATA + 4 NVMe configuration cabling for chassis 2 2 SAS/SATA + 4 NVMe configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 145
2 SAS/SATA + 4 NVMe configuration cabling for chassis 2 2 SAS/SATA + 4 NVMe configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 146
Midplane interposer port 2 Pink dot (callout 5) 2 SAS/SATA + 2 NVMe wtih E208i-p/P408i-p configuration cabling for chassis 1 2 SAS/SATA + 2 NVMe wtih E208i-p/P408i-p configuration cabling for chassis 1 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 147
Midplane interposer port 1 Pink dot (callout 4) 2 SAS/SATA + 2 NVMe wtih E208i-p/P408i-p configuration cabling for chassis 2 2 SAS/SATA + 2 NVMe wtih E208i-p/P408i-p configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 148
1 P28454-001 P408i-p/E208i-p port 1 MB storage interposer Red line and dots (callout 3) P408i-p/E208i-p port 2 P28450-002 Primary riser port 2 Midplane interposer port 1 Pink dot (callout 4) HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 149
8 NVMe configuration cabling for chassis 2 8 NVMe configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 150
Primary riser port 2 Midplane interposer port 2 Pink dot (callout 4) HPE NS204i-t Gen10 Plus NVMe Boot Controller NS204i-t Gen10 Plus NVMe Boot Controller -M.2 SSD module cabling -M.2 SSD module cabling HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 151
P28448-001 Secondary riser port 2 Half-width M.2 connector Red line (callout 1) 2 NVMe + M.2 configuration cabling for chassis 1 2 NVMe + M.2 configuration cabling for chassis 1 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 152
Pink dot (callout 2) P45750-001 Half-width MB port 1 Half-width M.2 connector Red (callout 3) 2 NVMe + M.2 configuration cabling for chassis 2 2 NVMe + M.2 configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 153
Pink dot (callout 2) P45750-001 Half-width MB port 1 Half-width M.2 connector Red (callout 3) 6 NVMe + M.2 configuration cabling for chassis 2 6 NVMe + M.2 configuration cabling for chassis 2 HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 154
HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 155
Pink dot (callout 3) P45750-001 Half-width MB port 1 Half-width M.2 connector Red (callout 4) HPE Smart Storage Battery cabling Smart Storage Battery cabling Power switch cabling Power switch cabling HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
U.3 Premium 8 SFF NVMe backplane power cabling U.3 Premium 8 SFF NVMe backplane power cabling Gen10 Plus 8 SFF SAS/SATA Standard backplane power cabling Gen10 Plus 8 SFF SAS/SATA Standard backplane power cabling HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
U.3 Premium 8 SFF NVMe backplane power cabling U.3 Premium 8 SFF NVMe backplane power cabling Uses the Front Panel Pass-Thru Board to Drive Backplane Power cable. GPU power cabling GPU power cabling HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 158
4 double-width PCIe GPU to PCIe GPU board power cabling 4 double-width PCIe GPU to PCIe GPU board power cabling One Power, slot board PCIe eight to PCIe eight cable. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
HPE 3000 W 200–277 VAC Platinum Hot-plug Power Supply HPE 54 V Out 3000 W 200–277 VAC Hot-plug Power Supply HPE 54 V Out 3000 W 200–277 VAC Hot-plug Power Supply HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Page 160
3000 W at 200 VAC to 277 VAC input Maximum peak power 3900 W for 4ms at 200 VAC to 277 VAC input Maximum inrush current duration 0.2 ms at 200 VAC to 277 VAC input HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
For more information on static electricity or assistance with product installation, contact the Hewlett Packard Support Center Hewlett Packard Support Center . Websites Websites General websites General websites Single Point of Connectivity Knowledge (SPOCK) Storage compatibility matrix https://www.hpe.com/storage/spock https://www.hpe.com/storage/spock HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
To gain the full benefits of the Hewlett Packard Enterprise Support Center and your purchased support services, add your contracts and products to your account on the HPESC. When you add your contracts and products, you receive enhanced personalization, workspace alerts, insights through the dashboards, HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
If your product includes additional remote support details, use search to locate that information. HPE Get Connected https://www.hpe.com/services/getconnected https://www.hpe.com/services/getconnected HPE Tech Care Service https://www.hpe.com/services/techcare https://www.hpe.com/services/techcare HPE Complete Care Service https://www.hpe.com/services/completecare https://www.hpe.com/services/completecare Warranty information Warranty information HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Feedback button and icons (at the bottom of an opened document) on the Hewlett Packard Enterprise Support Center portal (https://www.hpe.com/support/hpesc https://www.hpe.com/support/hpesc) to send any errors, suggestions, or comments. This process captures all document information. HPE ProLiant XL645d Gen10 Plus Server Maintenance and Service Guide...
Need help?
Do you have a question about the ProLiant XL645d Gen10 Plus and is the answer not in the manual?
Questions and answers