Technical Support & Trouble www.inheco.com/tech-support.html Shooting Instructions: INHECO Industrial Heating and Cooling GmbH reserves the right to modify their products for quality improvement. Please note that such modifications may not be documented in this manual. This manual and the information herein have been assembled with due diligence.
5 Initial operation ............................26 5.1 Connecting devices to the MTC / STC......................26 5.2 Programming the movement Pattern ......................27 6 Operation ..............................28 6.1 Safety instructions for operation ........................28 6.2 Getting the device in closed position ....................... 29 Teleshake AC Devices...
Page 4
7.4 Calibration / Verification ..........................33 7.5 Return for Repair only with RMA Number ......................33 7.6 Transportation and Storage ..........................33 7.7 Shut Down and Disposal........................... 34 8 Trouble Shooting and Support ........................35 9 Accessories ..............................36 Teleshake AC Devices...
– This manual is part of the device and must be retained until the device is disposed of or must be passed on with the device to new users. – Contact INHECO if there are any uncertainty in operation or handling of the device.
Inch In Vitro Diagnostic Kelvin Kilogram Pounds Millimeter Multi TEC Control controls up to 6 INHECO devices individually Offset The difference between the set temperature and actual value once the temperature is stable Protective Earth Relative humidity Revolutions per minute...
Broken seals on INHECO devices lead to the loss of warranty as well. INHECO will only accept parts / devices for return that do not pose a threat to the health of our staff. In particular, the devices may not have been used in Biosafety Level 3 and 4 environments or have been exposed to radioactive or radiation materials.
– Ensure that there is no other device installed next to the device increasing the inlet air temperature for the device above the specified temperatures. In case of doubt, please contact INHECO for further analysis. – Do not exceed minimum or maximum ambient temperature and humidity conditions during operation or storage of the device →...
– Make sure that the device does not come in contact with liquids while the device is connected to the power outlet. – Use the original power cable provided by INHECO to ensure safe and proper operation. – The product must be connected directly to an approved power source, for example to a three-wire grounded socket for the 230 V / 110 V / 90 V line.
CRUSHING HAZARD If the required warning notices are not observed, physical injuries can occur from closing mechanical parts of a machine. Table 1: Danger Signs Teleshake AC Devices...
This information symbol indicates important instructions that should be observed in order to avoid problems with the product. INFORMATION This information symbol indicates useful notes that should be observed in order to work optimally with the product. Table 2: Information Symbols Teleshake AC Devices...
In case of parcel or product damages, take photos of the damaged boxes and products and email them to techhotline@inheco.com immediately. Transportation damages must be reported to INHECO within 7 days of delivery. The following components should be included in each shipment:...
STC). → Initial operation, page 26. Functional elements In the following chapters the Teleshake AC is shown, as the clamping mechanism is identical to all Teleshake devices. If there are differences in other functional elements, they are clearly pointed out.
Illustration 4: Clamp mechanism "Closed" WARNING Pinching of finger While the clamp mechanism is closing you might pinch your finger or your glove. Closing or opening takes about 2-5 sec. Fixation Pins 3.3.2 Illustration 5: Fixation Pins of Clamp Mechanism Teleshake AC Devices...
NOTICE Shaking Frequency The Teleshake AC USB is a highly integrated, powerful shaker that can be operated beyond its recommended limits. This has an impact on the expected service life of the device. The maximum possible load and shaking frequency are dependent on many physical factors.
New labels can be ordered at INHECO. In case the label is missing and you do not know the part number and serial number, they can also be read out with the software (Device Manager) which can be downloaded from INHECO´s customer area on www.inheco.com.
Depending on the load, as otherwise liquid might get spilled or adapter might not be hold tight to the clamp mechanism. We recommend testing the speed you want to use with a microtiter plate and water to test the behavior first. Teleshake AC Devices...
Page 19
Tolerable relative humidity Operation 10-80% RH (non condensing) Transportation and storage 10-80% RH (non condensing) Temperature Operation +15°C to +32°C [+59°F to 90°F] Transportation and storage -10°C to + 60°C [+14°F to 140°F], non condensing Table 4: Environmental Conditions Teleshake AC Devices...
→ Removal of fixation pins, page 21. Visit www.inheco.com to find the custom-fit adapter for your microplate and contact sales@inheco.com in case you need a custom-fit holder.
Access for open-end wrench (3 mm) Step 1: Use the open-end wrench to screw the new pins back in position. Info In case the standard fixation pins don’t work with your plate please contact INHECO (sales@inheco.com) for customized fixation pins. Teleshake AC Devices...
/ assay. The adapter may facilitate accurate positioning for easy robotic handling plate. Visit www.inheco.com to find the adapter which fits your tube, reservoir or plate. In case you do not find your microplate on the list of adapters, ask sales@inheco.com for a custom design.
For transportation of the device the shaker needs to be in closed position. Drilling schematic for secure mounting of the device. Illustration 14: Drilling Scheme NOTICE The Shaker always needs to be fixed to the ground for proper shaking performance. Teleshake AC Devices...
Page 24
Information for teaching your robotic system: The closed position of the clamps can be adjusted via firmware commands to ensure a proper clamping force. The open position is not adjustable and the device will always fully open when prompted. Teleshake AC Devices...
INHECO Installation | 4 Software Installation INHECO offers a software called Demo Tool to provide limited functional control (also possible via touchscreen of the MTC / STC) and the opportunity to send manually entered firmware commands to the devices. We recommend contacting your workstation provider for integration (including software integration) of the MTC / STC with devices into your workstation.
Initial operation Connecting devices to the MTC / STC In order to connect an INHECO heating / cooling / shaking device, the TEC Control Unit has to be equipped with the corresponding Slot Module. There are blue, black, and yellow Slot Modules available. The following table shows the appropriate Slot Module for each heating / cooling / shaking devices.
Never plug in or plug out a device while the Controller is running. Always turn off the Controller before disconnecting or connecting the device. Programming the movement Pattern The only movement pattern of the device is orbital and anticlockwise. Illustration 16: Shaking pattern Teleshake AC Devices...
Demo Tool available as download from the customer area at www.inheco.com or by the software of your liquid handling workstation. The INHECO Demo Tool software and the touchscreen allow programming basic temperature and shaking sequences. More complex control sequences can be performed with the software of your robotic platform provider or if you write your own software based on our Firmware Command Set and DLL.
In case the clamp mechanism has a problem to open there are several ways to open it: Illustration 18: Clamp mechanism "Open" with lever (Arrow) With commands via Demotool Use the commands xSSR0 and xASE0 (x= slot ID) as soon as the shaking is stopped. Teleshake AC Devices...
Page 30
By restarting the controller After restarting the computer, the clamp mechanism is opened and in zero- position. Using the lever If sending the commands or the restart is not successful, you can use the lever to open the clamp mechanism. Teleshake AC Devices...
For updates of the Demo Tool Software, contact: sales@inheco.com. Installation of the Software "MTC / STC Demo Tool" 7.1.1 The Demo Tool can be downloaded from INHECO´s customer area on www.inheco.com. In this section you will also find the Demo Tool Manual with detailed instructions of the software.
Liquids must not enter into the unit. Do not use aggressive cleaning fluids such as acetone, or abrasive cleaners. Contact INHECO in case you prefer other cleaning liquids or methods as they might be harmful for the material of the devices.
INHECO for return. Ask techhotline@inheco.com or visit www.inheco.com/service/returns-rma.html for the return procedure before you return a device to INHECO. Do not return any devices without INHECO’s RMA number. INHECO’s RMA number must be shown on the outside of the return package.
Shut Down and Disposal The device must be disposed of in accordance with environmental and biosafety directives. You must arrange for correct electric waste disposal following current safety regulations of your country. All INHECO devices are RoHS and WEEE compliant. Teleshake AC Devices...
– INHECO product number of the device (shown on device label) – INHECO product name of the device (shown on device label) – INHECO serial number of the device (shown on device label or via software) – Detailed error description –...
CPAC (only 7000190 & 7000179) Module Yellow Slot yellow 2400211 Thermoshake AC, Thermoshake AC 180, Module Thermoshake AC LC, Teleshake 95 AC Thermal Adapter A list of adapters (inserts, nests) can be downloaded from INHECO´s webpage www.inheco.com or requested from sales@inheco.com. Teleshake AC Devices...