USE AND MAINTENANCE MANUAL ATTILA TABLE OF CONTENTS TABLE OF CONTENTS ......... 3 8. USE............. 27 8.1. CHECKS BEFORE use ........27 TECHNICAL DATA SHEETS ......5 8.2. SWITCH-ON ............. 27 USE AND MAINTENANCE MANUAL ..... 7 8.3. Product load to be blasted ........ 28 8.4.
USE AND MAINTENANCE MANUAL ATTILA TECHNICAL DATA SHEETS ABBATTITORE ATTILA m³); ite;...
Page 6
ATTILA ATT02 Blast chiller, 3 GN 2/3 trays (354 x 325 mm) SUITABLE FOR BLASTING GASTRONOMY FISH MEAT BREAD PASTRIES ICE CREAM FUNCTIONS VENTILATION TIME BLASTING DEFROSTING FREEZING BUZZER PROBE PIN TECHNICAL FEATURES ▪ Version Digital ▪ With incorporated unit (CG) ▪...
Carefully read this manual before carrying out installation, maintenance and/or before using the equipment. This manual is attached to the equipment ATTILA - ATT02. The Manufacturer is not liable for breakages, accidents or various problems due to non-compliance with and in any case the non-application of the provisions contained in this manual.
USE AND MAINTENANCE MANUAL ATTILA 1.4. REGULATORY FRAMEWORK The equipment is designed according to the regulatory framework described in the accompanying declaration of conformity and the identification plate placed on the same, as well as the requirements, which can be downloaded directly from the manufacturer’s website.
ATTILA SAFETY WARNINGS The Manufacturer cannot be held liable for any damage, suffered by people or things, caused by non-compliance with the aforementioned requirements or deriving from tampering with even a single part of the equipment and from the use of non-original spare parts.
USE AND MAINTENANCE MANUAL ATTILA Only use original spare parts. It is strictly forbidden to make changes to the equipment. Do not start the equipment with wet hands or when there is contact with water. 2.1. OBLIGATIONS AND PROHIBITIONS 2.1.1.
ATTILA IDENTIFICATION AND DESCRIPTION 3.1. EQUIPMENT IDENTIFICATION The nameplate is on the rear of the equipment. Contains: ▪ Serial number ▪ The type/functional features ▪ The details of the certification and marking. Do not remove the identification plate and/or replace it with other plates.
USE AND MAINTENANCE MANUAL ATTILA 3.2. INTENDED USE The equipment is a BLAST CHILLER for professional use. It enables previously cooked food products to be cooled rapidly. It works in the following modes: ▪ Positive blasting = up to +10°C/ +3°C ▪...
ATTILA 3.4. MAIN COMPONENTS POS. ELEMENT NOTES STRUCTURE CONTROL PANEL DOOR WITH HANDLE SHELF SHELF SUPPORT REMOVABLE CONDENSATE DRIP TRAY Including: ▪ EVAPORATOR UNIT ▪ Resistor FEET Including: ▪ Compressor ▪ REFRIGERATING UNIT Capacitor ▪ Chamber temperature probe ▪ CORE PROBE...
USE AND MAINTENANCE MANUAL ATTILA RECEIPT AND HANDLING 4.1. EQUIPMENT RECEIPT The equipment is delivered on a pallet packed in strapped cardboard. Upon delivery, check that the packaging is intact and that it has not been damaged during transport. 4.1.1.
ATTILA 4.1.2. PACKAGING REMOVAL AND INSPECTION For the removal of the packaging: STEP ACTION PICTURE Remove the bands. Remove the packaging cardboard. Togliere l’imballo in cartone; Sganciare le protezioni in plastica dei piedini; Lift the equipment to remove it from the pallet.
HANDLING 4.2.1. VERSION AND WEIGHT DIVISION FOR HANDLING VERSION PACKING SIZE GROSS WEIGHT ATT02 L.715 x D.725 x H.590 mm 56 Kg 4.2.2. HANDLING OPERATIONS Carefully read the instructions before moving the equipment. Only qualified technical personnel should perform handling operations on the equipment.
ATTILA INSTALLATION Only qualified technical personnel should perform installation operations on the equipment. The manufacturer accepts no liability in the event of non-compliance with current safety regulations. Do not install and use the equipment in ATEX classified environments, locations or areas.
USE AND MAINTENANCE MANUAL ATTILA 5.1.2. MINIMUM SAFETY DISTANCES In order to ensure proper functioning of the equipment and thus proper air circulation, observe the minimum safety distances from side walls, other equipment and/or heat sources. MINIMUM SAFETY DISTANCES Side / Rear / Upper...
ATTILA 5.2. FEET PLACEMENT AND ADJUSTMENT Position the equipment perfectly level, so that it can work properly, the condensation water from the defrosting process can drain off correctly and there are no noisy vibrations of the motor. For positioning and adjusting the equipment feet:...
USE AND MAINTENANCE MANUAL ATTILA CONNECTIONS 6.1. ELECTRICAL CONNECTION Only qualified technical personnel should perform connection operations on the equipment. The electrical connection must be carried out in accordance with the legal compendium and regulations applicable in the country where the equipment is installed.
ATTILA CONTROL PANEL 7.1. DIGITAL INTERFACE POS. ICON ELEMENT DESCRIPTION DISPLAY Displays the equipment operating parameters. Press and release Scrolls through the menu. Increases time or temperature of selected cycle. If the buzzer is active Muting of buzzer (on first press).
USE AND MAINTENANCE MANUAL ATTILA POS. ICON ELEMENT DESCRIPTION ▪ Steady on: compressor on. ▪ Compressor LED Flashing: delay, protection or activation blocked. ▪ Off: in all other cases. ▪ Steady on: evaporator fans on. Fans LED ▪ Off: in all other cases.
ATTILA 7.2. CYCLE-DEPENDENT INTERFACE CHARACTERISTICS The commands on the interface take on characteristics depending on the operating cycle of the equipment. STOPPING PHASE The display shows the time (in minutes) if a time cycle is selected, or the temperature of the core probe in °C for a probe cycle.
USE AND MAINTENANCE MANUAL ATTILA 7.3. ADJUSTING OPERATING PARAMETERS For adjusting the operating parameters of the equipment, via control panel: STEP ACTION Press the buttons simultaneously for at least 4 sec. The display shows "ABB". Note: the equipment must be switched off/in stand-by.
Page 26
ATTILA CODE DESCRIPTION DEF. MIN. UNIT Dripping duration. min. Core set for positive blasting. °C Core set for negative blasting. °C Core set for deep blasting. °C Chamber set for positive blasting. °C Chamber set for negative blasting. °C Chamber set for deep blasting.
USE AND MAINTENANCE MANUAL ATTILA Before using the equipment, check that it is in perfect condition. In the presence of faults, the equipment must be decommissioned and the Technical Assistance Service must be contacted. CAUTION Keep all the supply and return air ventilation openings inside the equipment free of obstructions.
ATTILA 8.3. PRODUCT LOAD TO BE BLASTED Load a maximum of 1 kg on each shelf. The load must be evenly distributed on the shelf. Pre-cool the chamber before starting the positive and negative blasting cycle. For proper blast chilling, do not introduce hot products. Wait for the product to cool down before placing it inside the equipment.
USE AND MAINTENANCE MANUAL ATTILA 8.4. PRODUCT BLASTING The following is purely indicative. The responsibility for blasting processes lies solely with the user of the equipment, who must comply with the local regulations and Good Practice Manuals (GHP) applicable by him/her.
ATTILA 8.4.3. BLASTING CYCLE WITH CORE PROBE To carry out the blasting cycle with a core probe, proceed as described below: STEP ACTION Press the button to select standard temperatures (+3°C; -18°C; -35°C; inf.). If necessary, use the buttons to set the temperature of the blast chilling cycle.
USE AND MAINTENANCE MANUAL ATTILA 8.4.4. TIMED BLASTING CYCLE To carry out the timed blasting cycle, proceed as described below: STEP ACTION Press the button on the control panel to select the standard times (90; 270). If necessary, use the buttons to set the time for the blasting cycle.
ATTILA 8.4.5. BLASTING TIMES The following is purely indicative. The responsibility for blasting processes lies solely with the user of the equipment, who must comply with the local regulations and Good Practice Manuals (GHP) applicable by him/her. The Manufacturer is not liable for damage to property or persons.
USE AND MAINTENANCE MANUAL ATTILA MAXIMUM PRODUCT FOOD BLASTING TIME CYCLE USED LOAD THICKNESS PASTRY/DESSERTS Vanilla and chocolate pudding 4-5 cm 90 minutes POSITIVE English cream 4-5 cm 90 minutes POSITIVE Custard 4-5 cm 90 minutes POSITIVE Panna cotta (single portion)
ATTILA CLEANING 9.1. CLEANING SAFETY WARNINGS WARNING Electrical hazard. Disconnect the power supply before cleaning. WARNING Electrical hazard. Do not use water jets and/or high-pressure lances to wash the internal and external parts of the equipment. WARNING Do not damage the refrigerant fluid circuit.
USE AND MAINTENANCE MANUAL ATTILA 9.2. TABLE OF CLEANING OPERATIONS The table lists a number of cleaning operations to be performed according to the recommended schedule. FREQUENCY OPERATION AT 6-MONTHLY DAILY WEEKLY MONTHLY YEARLY INTERVALS ■ Cleaning inside ■ Cleaning the loading area ■...
ATTILA MAINTENANCE WARNING Electrical hazard. Disconnect the power supply before carrying out maintenance work. Only authorised technical personnel should service the equipment. 10.1. ROUTINE MAINTENANCE Ensure smooth operation over time of the equipment by performing periodic/preventive checks and maintenance. 10.1.1.
USE AND MAINTENANCE MANUAL ATTILA 10.2. SPECIAL MAINTENANCE Special maintenance includes service, repair, and restoration of nominal operating conditions or replacement of a faulty, defective or worn component. 10.2.1. REPLACEMENT OF MOTOR FAN For replacement, contact the Authorised Dealer or Service Centre.
ATTILA DIAGNOSTICS 11.1. ALARMS MESSAGE CAUSE TYPE OF ERROR SOLUTIONS If the wire is disconnected, Check that all terminal Generic or internal probe reinsert it into the terminal board wires are plugged in. error. and tighten the screw. If the wire is disconnected, Check that all terminal Chamber probe error.
USE AND MAINTENANCE MANUAL ATTILA DECOMMISSIONING AND DISPOSAL 12.1. LONG PERIODS OF INACTIVITY If the equipment is not used for a long period of time (more than 2-3 weeks): STEP ACTION Disconnect the power supply. Carry out a thorough cleaning of the equipment (see chapter 'CLEANING').
ATTILA ATTACHMENTS 13.1. WIRING DIAGRAM EWBC432EO 10 11 10 11 M1: COMPRESSOR (ML.TB). MC: FAN MOTOR ON CAPACITOR AND COMPRESSOR COOLING. ME: FAN MOTOR ON EVAPORATOR. PSP: INTERNAL HEATER TO DOOR EDGE PLASTIC. S1: OPEN DOOR SWITCH. R2: PROBE IN THE PTC REFRIGERATED CHAMBER.