Installation Guide
Included Installation Instructions
Base Bracket
WV
QJB501
-
Model No.
• Before attempting to connect or install this product, please read these instructions carefully and
save this manual for future use.
• The external appearance and other parts shown in this manual may differ from the actual
product within the scope that will not interfere with normal use due to improvement of the
product.
i-PRO Co., Ltd. assumes no responsibility for injuries or property damage resulting
from failures arising out of improper installation or operation inconsistent with this
documentation.
"<Control No.: C****>" used in these documents should be used to search for
information on our technical information website (https://i-pro.com/products_and_
solutions/en/surveillance/learning-and-support/knowledge-base/technical-information)
and will guide you to the right information.
https://www.i-pro.com/
© i-PRO Co., Ltd. 2024
Caution:
• Before attempting to connect or operate this product, please read these instructions
carefully.
Notice:
• This product is not suitable for use in locations where children are likely to be present.
• Do not install this product in locations where ordinary persons can easily reach.
• For information about screws and other parts required for installation, refer to the
corresponding section of this document.
Precautions
„ Refer installation work to the dealer.
Installation work requires technique and experience.
Failure to observe this may cause fire, electric shock, injury, or damage to the product.
Be sure to consult the dealer.
„ Install the product accurately and securely on the installation surface in accordance
with the installation instructions.
Failure to observe this may cause injury or accidents.
„ The screws and bolts must be tightened to the specified torque.
Failure to observe this may cause a drop resulting in injury or accidents.
„ Do not use this bracket except with suitable cameras.
Failure to observe this may cause a drop resulting in injury or accidents.
„ Do not rub the edges of metal parts with your hand.
Failure to observe this may cause injury.
When using this product, also read the "Precautions" described in the operating
instructions for the camera to be attached.
Preface
Mount the camera onto the ceiling or wall using this bracket. Use this bracket when conduits are
used for wiring, or when there is no space available for wiring in the ceiling or the wall.
The latest information about the supported cameras <Control No.: C0501>
Specifications
Ambient operating temperature: –50 °C to +60 °C {–58 °F to +140 °F}
Dimensions:
Mass:
Finish:
Precautions for installation
„ In order to prevent injury, this product must be securely mounted to the installation
surface according to Installation Guide.
„ Make sure to remove this product if it will no longer be used.
Standard Accessories
Operating Instructions (this document) ....................................................................................1 pc.
Fixing screws for attachment plate (M4 × 8 mm {5/16 inches}) ............................................. 5 pcs.
Template B (for the base bracket) ....................................................................................... 1 sheet
Other items that are needed (not included)
⿟ Mounting screws
Installation method
Directly mount the camera onto the
installation surface.
*1 Select screws according to the material of the location that the camera will be mounted to.
In this case, wood screws and nails should not be used.
*2 This value indicates the minimum pull-out strength required value per screw.
For information about the minimum pull-out strength, refer to our technical information
website <Control No.: C0120>.
*3 The screw length is an example when installing the camera on a robust ceiling or wall with a
thickness of 20 mm {25/32 inches} or more.
Cs0522-1104
⿟ 5 mm {3/16 inches} hexagon wrench (When using a conduit.)
Printed in China
Installation
Step1
A 85 mm {3-11/32 inches}
B 138 mm {5-7/16 inches} 138 mm {5-7/16 inches}
C 83.5 mm {3-9/32 inches} 46 mm {1-13/16 inches}
D 63 mm {2-15/32 inches} 63 mm {2-15/32 inches}
E* –
F 70 mm {2-3/4 inches}
„ When using the conduit on the ceiling or wall
for wiring
This product
Cap for the
female thread
for the conduit
5 mm {3/16 inches} hexagon wrench
(locally procured)
• The female thread for conduit is compliant with ANSI NPSM (parallel pipe threads) 3/4 or ISO
228-1 (parallel pipe threads) G3/4.
Step2
Mounting screw
M4 (4 pcs./2 pcs.)
(locally procured)
Minimum pull-out strength:
196 N {44 lbf} (per 1 pc.)
ø164 mm × 41.4 mm (H)
{ø6-15/32 inches × 1-5/8 inches (H)}
Approx. 450 g {0.99 lbs}
Aluminum die cast
i-PRO white
(WV-QJB501-W)
Black
(WV-QJB501-B)
Light gray
(WV-Q193)
Recommended screw*
M4 × 16 mm*
{5/8 inches} × 4 or 2 pcs.
Vertical direction
Horizontal direction
85 mm {3-11/32 inches}
(85.7 mm {3-3/8 inches})
(85.7 mm {3-3/8 inches})
83.5 mm {3-9/32 inches}
108.5 mm {4-9/32 inches}
Conduit fixing position
FRONT
Attachment plate
(camera accessory)
Recommended tightening
torque:
0.78 N·m {0.58 lbf·ft}
(of them, 1 for spare)
Minimum pull-out
1
strength*
2
3
196 N {44 lbf}
* When mounting to a single-gang
junction box, fix it with screws
(2 pcs.) (M4: locally procured).
Cable access hole
ø25.4 mm {ø1 inch}
(2 places)
51 mm
{2 inch}
51 mm
{2 inch}
Fixing screw for
attachment plate
(4 pcs.) (accessory)

Advertisement

loading
Need help?

Need help?

Do you have a question about the WV-QJB501 and is the answer not in the manual?

Questions and answers

Summary of Contents for i-PRO WV-QJB501

  • Page 1 Operating Instructions (this document) ..................1 pc. Fixing screws for attachment plate (M4 × 8 mm {5/16 inches}) ..........5 pcs. i-PRO Co., Ltd. assumes no responsibility for injuries or property damage resulting (of them, 1 for spare) from failures arising out of improper installation or operation inconsistent with this Template B (for the base bracket) ..................
  • Page 2 取り付け可能なカメラの最新情報 <管理番号:C0501> 工事説明付き 仕様 ベース金具 使用温度範囲 -50℃~+60℃ WV-QJB501 品番 寸法 φ164mm×41.4mm(H) 質量 約450g 仕上げ アルミダイカスト  i -PROホワイト(WV-QJB501-WUX)  /黒(WV-QJB501-B) 設置上のお願い このたびは、弊社製品をお買い上げいただき、まことにありがとうございます。 ⿟ 取扱説明書をよくお読みのうえ、正しく安全にお使いください。 ■ 設 置工事は電気設備技術基準に従って実施してください。 ⿟ ご使用前に「安全上のご注意」を必ずお読みください。 本金具の設置・接続を始める前に必要な周辺機器やケーブルを確認し、準備してください。 ⿟ この取扱説明書は大切に保存してください。 接続する前に、カメラ、PCなど接続する機器の電源を切ってください。 ⿟ 製品の改良などにより、ご使用上影響のない範囲で、記載されている外観などが実際の製 ■ 傷害防止のため、本金具は、設置の説明に従って設置面にしっかりと取り付ける 品と異なる場合があります。 必要があります。 ■ 本金具を使用しなくなった場合は放置せず、必ず撤去してください。...